Loading...
VI.1. Blake Road Station Planned Unit Development (PUD) Amendment for Site B; Lindahl April 19, 2022 City Council Report 2022-041 Blake Road Station Planned Unit Development (PUD) Amendment for Site B Proposed Action: Staff recommends the City Council adopt the following motion: • Move to adopt Resolution 2022-030 approving an amendment to the Blake Road Station Planned Unit Development (PUD) Agreement incorporating Site B (PID 19-117-21-42- 0046), subject to conditions. Overview The applicant, Bryan Farquhar of TF Hopkins, LLC (Trilogy Real Estate Group), requests an amendment to the Blake Road Station Planned Unit Development (PUD) to include Site B. The site plan for Site B was approved during the April 5, 2022 meeting conditioned on future approval of an associated PUD amendment to incorporate Site B into the original PUD. Staff has worked with the applicant and the City Attorney to draft the attached PUD amendment to reflect the terms and conditions of the site plan for Site B and recommends approval. Primary Issues to Consider • Background • Planned Unit Development • Alternatives Supporting Documents • Site Location Map • Applicant’s Narrative • Resolution 2022-030 • Blake Road Station – First Amendment to the PUD Agreement • Plans and Building Elevations _________________ Jason Lindahl, City Planner Financial Impact: $ N/A Budgeted: Y/N ____ Source: _____________ Related Documents (CIP, ERP, etc.): _________________________________________ Notes: City Council Report 2022-041 Page 2 BACKGROUND The Blake Road Station PUD and Site Plan for Site A were approved in August 2021. The PUD included a master plan which mapped out three phases of development (Site A, B and C). The site plan for Site A was approved in conjunction with the original PUD and is currently under construction. As mentioned above, the site plan for Site B was approved by the City Council during the April 5, 2022 meeting subject to approval of the associated PUD amendment currently before the City Council. Should the City Council approve the PUD amendment, the applicant plans to begin construction of Site B this summer. Construction of Site C is subject to lease terms with the current Goodwill tenant but anticipated for some time after 2026. Future development of Site C will require separate site plan and PUD amendment approvals prior to construction. PLANNED UNIT DEVELOPMENT AMENDMENT The applicant received approval of the Blake Road Station PUD and associated Master Plan in August of 2021. The PUD establishes the Mixed Use zoning district and its development regulations as the base zone and standards for review. Overall, the original PUD entitled lot configuration, access and private road configuration, and building height for all 3 sites as well as various deviations specific to Site A. Review of Site B requires separate site plan review approval based on the entitlements established in the PUD Master Plan noted above and the specific zoning standards of the Mixed Use district. Deviations from the Mixed Use standards, other than those noted above require an amendment to the existing Blake Road Station Planned Unit Development (PUD) agreement. As you may recall, the purpose of a PUD is to allow flexibility from traditional development standards in return for a higher quality development. Typically, the City looks for a developer to exceed other zoning standards, building code requirements or meet other goals of the Comprehensive Plan. In exchange for the flexibility offered by the planned unit development, the applicant is expected to detail how they intend to provide a higher quality development or meet other City goals. The requested deviations and items offered by the developer in exchange for the requested deviations for Site B are compared in the table below. These deviations were evaluated as part of the site plan review process and are incorporated into the original PUD through the attached PUD amendment. PUD Comparison for Blake Road Station Site B Requested Deviations Items Offered to Support the PUD Building Height Transit Supportive Density Floor to Area Ratio Linear Park Setbacks on all 4 Sides of the Building 20 EV Charging Stations Parking Stall Dimensions Additional Landscaping Exterior Building Materials Transparency & Fenestration Façade Articulation It should also be noted that the applicant’s narrative for the original PUD states their intent to City Council Report 2022-041 Page 3 subdivide these properties as part of future development of Site C. Because this project is along a county road, both the City of Hopkins and Hennepin County will have plat review authority. With any subdivision, the City has the ability to collect park dedication in the form of land or a fee-in-lieu. The original PUD established the park dedication rates in place in 2021 which were $3,000 per unit for multiple family residential and five (5) percent of the fair market value of the commercial land as estimated by the county assessor. ALTERNATIVES 1. Vote to approve an amendment to the Blake Road Station Planned Unit Development Agreement to incorporate Site B. By voting to approve, the amendment to the Blake Road Station Planned Unit Development Agreement incorporating Site B will be approved. 2. Vote to deny an amendment to the Blake Road Station Planned Unit Development Agreement to incorporate Site B. By voting to deny, the PUD amendment will be denied. Should the City Council consider this option, it must also identify specific findings that support this alternative. 3. Continue for further information. If the City Council finds that further information is needed, the items should be continued. Site Location Map for Blake Road Station Subject Property Blake Road Station -- pg 1 Blake Road Station – Phase B Project Narrative – Formal Review 2022-02-18 Submission (03-17-22 Update) PROJECT OVERVIEW The Blake Road Station project is the redevelopment of 7.4 acres of land located at the intersection of Excelsior Boulevard and Blake Road South in Hopkins, MN. Trilogy Real Estate Group has been working with the City of Hopkins to develop the site in a three-phase, multi-modal transit-oriented development adjacent to the Blake Road Southwest LRT Station. The project received PUD and Phase A site plan approval in August of 2021, allowing for construction to begin on the first building in December of 2021. The second phase, which is the subject of the current site plan approval request, is situated on the corner of Excelsior and Blake Rd and will serve as a welcoming gateway to the project and City of Hopkins. When the third phase is completed, the development will be an anchor for the new transit station and will advance long-standing City goals outlined in numerous area planning documents, including the East Hopkins Land Use & Market Study (2003), Blake Road Corridor Small Area Plan (2009), Blake Road Corridor Study (2015) and the Blake Road LRT Station Area Development Guidelines (2015), as discussed in more detail in the latter part of this narrative. As early as 2003, the East Hopkins Land Use & Market Study confirmed that redevelopment within the City’s east end along Excelsior Boulevard and Blake Road would require a significant catalyst to help overcome certain existing barriers and obstacles to market delivery of such redevelopment. The applicant believes that the high-quality redevelopment of the project site and creation of a new transit- oriented node with significant residential density will provide such a catalyst. Each phase will build upon the improvements of the previous phase and will ultimately result in an increasingly connected, pedestrian friendly, and transit-focused community. The project will add to the mix of housing choices for area residents, providing a new opportunity to live immediately adjacent to the light rail transit station. STREETSCAPE AND PUBLIC REALM The development team has approached this site as a unique opportunity to complement the transformative power of the Southwest LRT line. Each phase of the Blake Road Station project defines and beautifies the streetscape while complementing the crucial transit functions in and around the site. Currently, two of the three parcels on the site are comprised of older, stressed pavement with ill- defined access and a plethora of surface parking stalls. The Planned Unit Development that was previously entitled will transform the site and emphasizes a neighborhood scale of connected streets, with traffic calming measures and pedestrian features that will significantly improve the aesthetic of the gateway to the City of Hopkins. This is the second of three parts of the projects vision that includes extensive pedestrian improvements for the area including sidewalk connections through the site with boulevards and a rhythm of deciduous street trees will provide a human-scale canopy year-round. The trees’ summer shade reduces the heat island effect, creating a comfortable microclimate when needed most. Both the trees and parallel parking zones will help to create visible friction that will successfully reduce driving speeds to provide a safer environment for people, bikers, and drivers. The pedestrian zone along Excelsior Boulevard and Blake Road expands to a width suitable for public street amenities including benches, bike racks, street lighting and planting beds. Phase B of the development will begin to define a new north-south street that divides the sites in two Blake Road Station -- pg 2 and will connect to the SWLRT station. This phase creates the spine between the first phase from which stems entries, active uses, and a newly created linear pocket park. Adjacent to the future use parcel that sits immediately to the north of this phase of the project, the pocket park will feature seating, natural play features, landscaping, and a pedestrian walk that offers a connection from Blake Road to the interior of the development. The pedestrian connection will provide flexibility to adapt to opportunities that may develop on the future use parcel that is not currently controlled by the applicant. BUILDING DESIGN Blake Road Station will provide creative, mid-rise residential buildings that maximize density while emphasizing green space and public realm at the street level. The proposed style of construction for Buildings B is five levels of wood framing over two levels of concrete podium and a below-grade level of parking; similar to Building A. Trilogy envisions a community that values leisure and comfort with the ease of urban connection. The exterior building design draws on these qualities of being a transition from an urban to naturalistic landscape. The architecture offers a refined exterior material palette that reinforces this site’s potential as a catalyst for beautiful design and smart growth in the Blake Station area of Hopkins. The palette, forms, colors, textures, and details create a coherent whole that is energizing and enduring. The design of Site B builds on the design language established by Site A. Where Site A has a warm, neutral tones to evoke a feeling of rural comfort, Site B uses similar materials and massing but in a higher contrast color scheme that is dressier and more formal, better suited to its location and role as a gateway building. While the forms of Site B are simple and peacefully resolved they are meant to have more of a “signature” presence both for the development and for the city of Hopkins. At street level, the sidewalk experience at the base of Site B is nearly identical to that of Site A. This is intentional so that the campus will have a sense of place with small differences that can be explored. The articulation in the masonry of Site B is also slightly more animated to enliven the pocket park. Site B has much more commercial square footage. The commercial sidewalk experience is metal clad. It has a clean and modern look, clearly differentiated from the residential and amenity areas at street level, while also maintaining specific historic references to a cornice and traditional façade signage. Blade signs also neatly slot into the elegant panel system used to define the retail facades. Building lighting is utilized to enhance the sidewalk experience throughout. At the upper levels, all facades are clad with durable materials. Masonry and medium gauge metals and composite metal panels along with quality windows comprise more than eighty percent of the façade surfaces on the primary sides of the building along Blake and Excelsior. The primary sides as well as the west side of the building are articulated with separate clearly defined masses, each with its own carefully composed façade whether the function within the building is residential, parking, retail, or private amenity. The projecting masses are wrapped consistently on all three sides, expressing how the building is organized into separate groupings in a beautiful and balanced architecture while also saying something about how each of the individual homes within are configured. Fiber cement lap siding is shown in recesses in order to visually separate these areas from the main facades’ more prominent architectural elements. As with Site A, the metal portions of the cladding on Site B will also have an attractive luster. Metallic luster allows the building to show its personality by dressing itself in the colors of its surroundings, most beautiful at sunrise and sunset but also softly echoing the glow of the carefully designed and manicured pedestrian realm at ground level, reflecting its current lighting configuration and its active uses. Blake Road Station -- pg 3 Amenity courtyards, balconies, and terraces extend living spaces to the outdoors while improved sidewalks and connections encourage active lifestyles for residents. Ground floor retail space will enhance the streetscape experience and provide an opportunity for retailers to have an intimate connection with residents, LRT riders, and the surrounding Hopkins community. With proximity to the Cedar Lake Trail, each building will supply ample storage and access to bicycle repair facilities to encourage bicycle use for recreation as well as daily commuting. Similar to Site A, these state-of-the-art dwelling units will support the residents’ sustainable living experience by providing urban housing that incorporates energy-efficient appliances, low-flow water fixtures, low-VOC paints, building-wide recycling practices and encouraging car-free living. The buildings will be designed to incorporate assemblies that ensure high-quality acoustical performance between units (wall and floor assemblies). DEVELOPMENT PHASING Commencement of construction of the various phases is dependent upon market conditions and existing lease agreements. Subject to those conditions, the development team currently anticipates the following construction start dates for the various phases: Building A: Under Construction Building B: Summer 2022 Building C: Spring 2026 – 2031 (pending existing lease agreements) CITY APPLICATIONS/APPROVALS  Previous Approvals • Zoning Application: Requesting rezoning from B-4 (Neighborhood Commercial) and I-1 (Industrial) to Mixed Use District • Planned Unit Development (PUD) Submittal (for the Overall Site) • Site Plan Approval for Site A (Site Plan Review Application) • Travel Demand Management Study approved by the City of Hopkins and Hennepin County • Execution of a Planned Unit Development Agreement  Site Plan Approval for Site B (Site Plan Review Application)  The development plan may necessitate re-platting of the land in future phase C  Approvals from the Minnehaha Creek Watershed District  Amendment to the Planned Unit Development Agreement Blake Road Station -- pg 4 PROPOSED DEVIATIONS FROM MIXED USE DISTRICT STANDARDS Strict adherence to the Mixed-Use District standards and requirements is not required in this case to satisfy the intent of the City’s planned unit development provisions and the proposed deviations from those standards will not prejudice the health, safety or welfare of the residents of the development, the surrounding area or the city as a whole. The proposed deviations from Mixed Use District standards for the Blake Road Station Site B are summarized in the following table: Requested Deviations Category Mixed-Use Standards Proposed for Site B Building Height 6 stories 7 stories granted with previous PUD approval Floor Area Ratio 3.0 2.8 South Setback 15’ – 25’ 10’-8” to 18’-2” on Levels 1 and 2 25’-1” to 30’-8” on Levels 3 thru 7 West Setback 15’ – 25’ 32’-8” to 49’-10” East Setback 15’ – 25’ 9’-8” to 28’-5” North Setback 10’ 5’-3” to 20’-7 on Levels 1 and 2 11’-1” to 20’-4” on Level 3 thru 7 Parking Stall Dimensions 9 ft x 20 ft 9 ft x 18 ft Primary Exterior Building Materials The zoning material guideline does not identify the metal panel tile as a primary or secondary material High-quality, primary materials of brick and glazing are proposed at Levels 1 and 2 of Building B. The applicant proposes the metal tile material as an equally durable and attractive option to other primary materials. Exterior Building Material Percentage 20% maximum for secondary materials such as fiber cement siding East elevation – Fiber cement siding, a secondary material, covers about 24% of the east elevation. Requested deviation to allow up to 30% for secondary materials on the east elevation. Building Transparency 60% transparency between 2 ft and 8 ft West elevation: 30% tinted or opaque glazing and 20% recessed brick is proposed between 2 and 8 ft.* Signage One monument sign permitted for each multi-tenant building provided the surface area of the sign does not exceed 2 sq ft per front foot of lot. No sign shall be over 150 sq ft, 20 feet in height and have a setback in no case less than 20 ft from the property lines. Approved as part of the PUD, a 3 ft x 6 ft monument sign at the southwest corner of Site B is proposed as a marker for Goodwill. Blake Road Station -- pg 5 SUPPORT FOR PROPOSED DEVIATIONS The applicant believes the development, as proposed with deviations from zoning code ordinances, is a high-quality proposal for the City of Hopkins and better aligns with overall Comprehensive Plan goals. To ensure a high-quality development, the applicant is proposing the following site enhancements in support of the proposed deviations: Enhanced Pedestrian Scale Architecture Primary building materials of brick, metal and glass are focused at the first two levels of the street-facing elevations. Other building elements such as canopies, building mounted light sconces, a trellis over the outdoor seating area and recessed balconies enhance the street presence and pedestrian experience at the ground floor. Stepping back the building at the third level along Blake and Excelsior creates a 2-story expression at focused pedestrian areas to further emphasize the human scale. Finally, the selected metal panel tile is both modern and traditional, with a shingle shape that creates a more residential scale at the upper-level elevations. Site signage will be constructed with materials that match the architectural style and materials of the building. The base of the primary monument sign for the development will be surrounded by landscaped planting beds and enhanced with seating opportunities. The development team is open to working out a solution for public art at this intersection. Active Uses and Building Transparency With effectively three front yards on Site B, the pedestrian scale design and site programming ensures articulation and interest on all sides, rounding out the 360-degree architecture of the building design. Active uses line the public street frontages with multiple retail spaces lining Blake Road and anchoring the southeast building corner. Shared building amenity spaces for residents will front Excelsior Boulevard with the primary residential entrance at the intersection of Excelsior and the new north-south internal road. Building accent lighting will enhance the building architecture throughout the site. The elevations along Blake Road and Excelsior Boulevard will meet or exceed the city ordinance minimum requirement of 60% transparency for front street-facing façades (between 2 ft and 8 ft). Where 60% transparency is not provided along the western elevation facing the private internal road, windows are provided into the parking garage and the wall is comprised primarily of brick. The wall acts as a backdrop for the public linear park and will be planted with trees and vines that will provide another layer of visual interest for passersby that varies with the seasons. The western façade will incorporate recessed detailing along with the glass, accounting for a total of 50% of the elevation (30% glazing and 20% recessed brick) The western drive is a private road created by the development team, so it is unclear if a deviation should be required for this frontage, as this isn't a city street. The north elevation will receive a similar treatment to the West with the addition of wrapping the retail detailing around the corner. Then elevating the visual interest and aesthetic with a balanced mix of glazing, brick accents and illuminated façade. There is no glazing or transparency requirement as it does not face the street or a public right-of-way, but ±20% tinted/opaque glazing is provided in addition to ±22% façade detailing with a recessed brick accent. Blake Road Station -- pg 6 Site Access Improvements The master plan for the new development aligns directly with goals from Station Area Planning documents. A new network of publicly accessible streets divides the site into pedestrian-scaled, walkable quadrants and connect the surrounding context to the SWLRT station. The new north-south street becomes the crucial spine from which stems primary building entries, active uses, and a public linear park. The east-west street further breaks down an otherwise super block, improving circulation and creating a tree-lined street with parallel parking and walk-up townhome units. As described under the ‘Streetscape and Public Realm’ section, the project vision includes extensive pedestrian improvements for the area, including sidewalk connections through the site that do not exist today. Both the trees and parallel parking zones will help to create visible friction that will successfully reduce driving speeds to provide a safer environment for people, bikers, and drivers. The pedestrian zone along Excelsior Boulevard (ranges from 28’ to 34 ft) and Blake Road (ranges from 17’-6” to 34 ft) expands to a width that supports public street amenities including benches, bike racks, street lighting and planting beds. The deviations for building setbacks are a result of the unique property configurations at this site, and the proposed setbacks provide comfortable buffer zones between street right-of-way and the building edges. The proposed setbacks offer a balance of enough distance to create green zones without compromising the more urban goals of transit-oriented development. This balance of ample though not excessive setbacks prioritizes pedestrians and human activity in and around the site. Along the northern edge of the site, a sidewalk is proposed within the rear yard. While this is not along a frontage road and therefore not required, Trilogy believes this added pedestrian pathway through the site will be a great amenity for the adjacent community. Providing this east-west connection will allow those walking along Blake Road or coming from the LRT station to access the interior of the site and the pocket park without having to walk up to Excelsior Blvd to do so. The sidewalk will be well lit with building mounted and bollard lighting. Native plantings will line the majority of the pathway, and decorative screening and a wood fence will provide visual interest along the way. Exceeding Stormwater Standards The applicant is exceeding the Minnehaha Creek Watershed District and City of Hopkins’ minimum standards for stormwater treatment. Runoff from this Site will be conveyed to the future 325 Blake Road regional stormwater treatment facilities via the Powell Road diversion. However, the new landscape areas, underground pipe retention systems and Jellyfish treatment structures proposed on- site will not only provide rate control but will treat the first 2-inches of rainfall from the impervious area. This is a substantial improvement from the site condition today as the site is primarily impervious surface and stormwater runs off without any treatment or attenuation. In summary, the new landscaping will help with stormwater abstraction and the underground treatment system will retain and treat stormwater in excess of MCWD and City standards. The proposed on-site stormwater management system exceeds MCWD/City standards by providing filtration treatment above the required 2” rainfall event. The detention systems (BMP 2A and BMP 2C) have the volume capacity to treat up to a 2.55” rainfall event. The proposed Jellyfish Filter systems (BMP 2B and BMP 2D) have the capacity to treat a flow rate of 1.30 CFS and 0.85 CFS, respectively. The corresponding modelled flow rates are 1.24 CFS and 0.72 CFS, which are within the filtration system treatment capacities. MCWD also requires 70% TSS removal, whereas BMPs 2B and 2D have an 80% removal efficiency. With 88% of Site capture, the filtration system provides 71% TSS removal. Blake Road Station -- pg 7 MCWD requires proposed runoff rates to be equal to or less than the existing condition. Total proposed site runoff rates are reduced by approximately 26-66% from the existing condition, depending on the rainfall event. The majority of the new/reconstructed site area will be dedicated to roof drainage, which is assumed cleaner than pavement runoff. This will further reduce pollutant loadings discharged from the site. The landscaped area within the study area is almost doubled from the existing conditions as well. Due to contaminated groundwater conditions, this additional landscape area has not been included in the model for viable infiltration to be conservative, but the new landscape areas will certainly provide additional volume reduction in reality. Enhanced Landscaping The deviations in setbacks offer yards that are both deep enough for landscaping and green space and reasonable for creating a "street wall" for the pedestrian experience. The deviations also help to implement a comprehensive plan goal of creating a ‘positive relationship to the street’ by proposing appropriate setbacks for the residential density guided by the 2040 Comprehensive Plan (75-150 units per acre within ¼ mile of an LRT station platform). As previously mentioned under ‘Streetscape and Public Realm,’ the master plan includes generous planted zones (6 ft to 12 ft wide) and a rhythm of deciduous street trees that will provide a human-scale canopy year-round. The trees’ summer shade reduces the heat island effect, creating a comfortable microclimate when needed most. A linear public park is proposed on the western edge of Building B. The pocket park offers opportunities for a quick hangout spot or a chance for larger community gatherings to occur. A central plaza space of crushed stone, column lights, artful concrete ‘asterisk’ blocks and moveable café tables/chairs provide flexible seating arrangements. A mini stage for small performances is proposed along with some nature play balance sculptural elements. Additional gabion wall seating is provided along the edges. A spot for a food truck offers potential food options. Native landscape plantings and trees contributes to a more natural backdrop. The streetscape will be greatly improved with new planning beds along Excelsior and Blake Road. Raised curb planting beds will be similar to Phase A and provide a visual continuity along Excelsior. New trees and plantings will help extend the existing Blake Road streetscape. Building edges are enhanced by green and planted yards with an array of site-appropriate species. This variety adds a visually interesting green environment and is a significant improvement from existing conditions today. Calculating the minimum landscape value based on the current project budget for Site B and per the City’s landscape code requirements (section 102-375 Landscaping), the minimum landscape value is approximately$103,000, with at least 25% allocated to pedestrian improvements. The estimated Landscape and Pedestrian/Streetscapes value for Site B will exceed the minimum landscape value requirement. We estimate that Site B will provide the following: - Trees: $33,000 - Shrubs: $25,000 - Grasses: $12,000 Blake Road Station -- pg 8 - Sod: $6,000 - Planting Soil: $25,000 - Edger/Mulch: $22,000 - Irrigation: $40,000 - Fencing/screening: $25,000 Excelsior & Blake Boulevards - Curb islands: $32,000 - Pavers: $26,000 - Site Furniture: $15,000 - Lighting: $25,000 TOTAL ESTIMATED LANDSCAPE VALUE PROVIDED $286,000 Specifics for Site B’s landscaping plan and plant species can be found within the application materials. Proposed Pet Exercise Area (Dog Park) & Relief Areas The importance of providing a formal exercise area for pets, specifically dogs, has been acknowledged by including a dog park along the west side of the future Site C building. The dog park will be fenced and includes small-scale lighting, seating and receptacles for proper disposal of animal waste. A dog relief area will be provided for use by residents along the west side of Building B. Bike Amenities With immediate access to the Cedar Lake Trail, ample bike amenities will promote the use of multiple modes of transportation for residents and patrons to the site. The city standard for bike parking is one long term stall per 2 units and one short term per 20 units (138 total bike racks). Building B will accommodate over 150 bike racks for resident storage within the building. The Mixed Use district bicycle parking requirements are 0.5 long-term spaces per employee and 0.5 spaces per 1,000 square feet of net building area or 5 spaces. Public bike racks (20 capacity) are located within the right-of-way adjacent to the primary Building B entrance as well as adjacent to the retail uses along Blake Road. A bike wash area with automatic shut off timer will be available in the P1 parking level. The development team is open to providing space on site to accommodate city micro mobility solutions in the future. Sustainable Design The project is enrolled in the Xcel Energy Design Assist (EDA) program to evaluate and prioritize strategies in order to maximize energy efficiency. See separate attachment for a comprehensive summary of the energy saving and sustainable design features of the project. Support of Comprehensive Plan Goals The project supports and further advances a number of goals outlined in the City’s 2030 Comprehensive Plan and draft 2040 Cultivate Hopkins Plan. See summary of these goals below within the PUD statement section. Blake Road Station -- pg 9 PLANNED UNIT DEVELOPMENT STATEMENT Per Hopkins, Minnesota, Code of Ordinances, Part III – Land Development, Chapter 102 – Planning and Zoning, Article XX. – Planned Unit Development, Sec. 102-680, (e), (6), the applicant is responding to the following:  A written statement generally describing the proposed PUD and the market which it is intended to serve and its demand showing its relationship to the city’s comprehensive plan and how the proposed PUD is to be designed, arranged and operated in order to permit the development and use of neighboring property in accordance with the applicable regulations of the city. Market The proposed Planned Unit Development is intended to serve the growing population of Hopkins and provide dwelling units within one quarter of a mile of the future Blake Road Southwest LRT Station. It is anticipated with the proposed future LRT station that this site will be a regional draw for apartment- dwellers. Trilogy will deliver an incredibly important development node along Blake Road, as envisioned in numerous planning documents, including the East Hopkins Land Use & Market Study, Blake Road Corridor Study and the Blake Road LRT Station Area Development Guidelines. This project will be an anchor for the LRT station and act as a catalyst for future development in the area. Many of the development recommendations outlined in the station area development guidelines are being realized within the proposed project. Here are just a few of the stated goals that will be supported by the project’s site and building design: Site Design:  Create a connected, walkable, mixed-use, sustainable neighborhood, with a pedestrian-oriented and human-scale streetscape  Improve safety and security with strategies such as greater security presence, improved lighting, and other practices such as CPTED (Community Policing Through Environmental Design)  Pursue transit-oriented design that enhances multi-modal access, and provide for bicycle accommodations (racks, lockers, etc.) for businesses and residents.  Add green space to soften the built environment that would allow for outdoor use year-round.  Utilize landscaping and streetscape amenities to create stronger pedestrian district.  Limit surface parking with new development encourage underground or structured parking Neighborhood Diversity:  Provide for a range of housing types and price points to meet the needs of people in all stages of life, with the design flexibility to accommodate changing lifestyle needs  Utilize universal design principles that can respond to changing demographic needs and anticipate in innovative ways to address the dynamic and changing needs of residents  Strengthen the vitality of the area through increased density and mixed commercial and residential uses  Promote high-quality design  Enhance a sustainable neighborhood by promoting energy efficiency and renewable energy  Create opportunities to live, work, learn, play – the spectrum of elements for a healthy community Sustainable Design: Blake Road Station -- pg 10  Improve water and environmental quality  Incorporate sustainable development practices into new construction projects Neighborhood vitality and livability:  Multi-family housing amenities such as guest suites, work-from-home opportunities, and shared space for larger gatherings  Medium to high density residential, to preserve green space and enhance street-level amenities  Locally owned businesses and increased opportunities for residents of all ages to live and work in the area  The potential for commercial uses that enhance rather than compete with downtown Hopkins Mainstreet vitality  Creative ways to support small cultural businesses that serve the community  Convenience services (e.g. pet maintenance areas, bike repair, etc.), especially near the transit station  Flexible space that can adapt as needs change  Welcome developers and businesses that operate with equity principles of hiring and wages Comprehensive Plan The 2040 Comprehensive Plan Update – Cultivate Hopkins – guides this property as Activity Center. Activity Centers surround and support the planned Blake Road and Shady Oak light rail stations along the Southwest LRT Green Line Extension. These areas will include moderate density to high-density mixed-use development designed to complement and enhance the existing development pattern in these areas and support the public investment in transit. The Activity Center areas are expected to experience significant reinvestment and redevelopment to absorb a substantial portion of the city’s anticipated future growth. Development in the Activity Center areas is expected to be medium to larger scale neighborhood and regional uses with an approximate mix of 75% residential and 25% commercial. Densities in these areas will typically range from 20-60 units per acre, with 75-150 units per acre within ¼ mile of an LRT station platform. The proposed project illustrates a residential density that is consistent with the Activity Center guidance, but it falls short of the 2040 guidance for commercial space percentage. Site A will provide 2,000 sq ft of retail space along Excelsior Boulevard and Site B will provide 10,000 sq ft of retail space fronting Blake Road. Trilogy is responding to current market conditions that are more immediate than a comprehensive plan’s land use guidance. The Retail Component Evaluation performed concluded that retail in this development is high-risk. The applicant is attempting to work with the City of Hopkins to address the retail desire, but also needs to be vigilant and not over supply the site. There are negative ramifications to continually vacant retail space. The applicant believes strongly that multi-family residential is highest and best use for this location. The constraints of the site are prohibitive to adding traditional retail space to the development. The Applicant is responding to the 2040 comprehensive plan with an overall development project that supports the following stated goals:  Encourage transit-oriented development (development that emphasizes pedestrian and bicycle connectivity and a broader mix of uses at densities that support transit) in areas with high quality transit service, especially within a quarter mile of light rail stations or high-frequency bus Blake Road Station -- pg 11 routes.  Plan for appropriate amenities, high-quality design, pedestrian and bicycle facilities, and open space in high growth areas, particularly in the Neighborhood Center, Activity Center, and Downtown Center future land use categories or other areas in close proximity to transit.  Encourage the transition of selected auto-oriented areas into Activity Centers, as defined and designated in the comprehensive plan.  Improve pedestrian and bicycle access throughout the community, particularly in the Centers future land use categories as defined and designated in the comprehensive plan or other areas in close proximity to transit.  Engage the community to explore how to increase the mix of housing types near transit corridors, parks, and the Centers future land use categories as defined and designated in the comprehensive plan.  Encourage all new projects to have a positive relationship to the street by orienting main entrances to the front of the property, connecting the front door to the sidewalk, and reducing parking between the building and the street as much as possible. Designed, Arranged, Operated This project will not impede improvement of surrounding properties, and the PUD is designed and arranged to permit the orderly development and use of neighboring property in accordance with the applicable regulations of the City. The organization of the parcels within this development is specifically intended to create a walkable, transit-oriented community. The height and associated density of the project will provide housing to help meet City goals for increasing housing options in Hopkins along transit corridors. The proposed residential and retail uses are compatible with and will enhance the existing character of the area. High-density, mixed-use redevelopment of this site is consistent with City goals and, by being responsive to the land use policies for this area, the project will promote the orderly development of the Blake Road Corridor. The contemporary, high-quality building design will be an attractive addition to this important intersection at Blake Road and Excelsior Boulevard, and the mix of uses will improve and activate the pedestrian realm. The proposed development will not be detrimental to or endanger the public health, safety, comfort or general welfare, and approving the PUD will allow a transit-oriented, mixed-use development that is consistent with the goals of City’s comprehensive plan. Infill development on the underutilized site will have a positive effect on the health, safety and vitality of the area. The new construction will comply with all building and site development codes. CITY OF HOPKINS Hennepin County, Minnesota RESOLUTION 2022-030 A RESOLUTION APPROVING THE FIRST AMENDMENT TO THE BLAKE ROAD STATION PLANNED UNIT DEVELOMENT AGREEMENT TO INCORPORATE SITE B (19- 117-21-42-0046), SUBJECT TO CONDITIONS WHEREAS, the applicant, Bryan Farquhar of TF Hopkins, LLC (Trilogy Real Estate Group), initiated an application for an amendment to the Blake Road Station PUD agreement to incorporate Site B into the original PUD agreement; and WHEREAS, the subject property is legally described as Lot 3, Hopkins Commerce Addition with PID 19-117-21-42-0046; and WHEREAS, the procedural history of the application is as follows: 1. That the above stated application was initiated by the applicant on February 18, 2022; and, 2. That the Hopkins Planning & Zoning Commission, pursuant to published and mailed notice, held a public hearing on the application and reviewed such application on March 22, 2022: all persons present were given an opportunity to be heard; and, 3. That written comments and analysis of City staff were considered; and, 4. That the Hopkins Planning & Zoning Commission reviewed this application during the March 22, 2022 meeting and recommended approval by the City Council, subject to conditions; and 5. That the Hopkins City Council reviewed this item during the April 19, 2022 meeting and agreed with the findings of the Planning & Zoning Commission. WHEREAS, staff recommended approval of the above stated application based on the findings outlined in the staff reports dated April 5, 2022 and April 19, 2022; and NOW, THEREFORE, BE IT RESOLVED that the City Council of the City of Hopkins hereby approves the First Amendment to the Blake Road Station Planned Unit Development (PUD) Agreement and authorizes the Mayor and City Manager to enter into this agreement, subject to the conditions listed below. 1. Execution of an amendment to the Blake Road Station Planned Unit Development (PUD) Agreement in a form acceptable to the City Attorney. 2. Approval of the associated Site Plan for Blake Road Station Site B and compliance with all associated conditions. Adopted by the City Council of the City of Hopkins this 19th day of April, 2022. By:___________________________ Patrick Hanlon, Mayor ATTEST: _______________________________ Amy Domeier, City Clerk 73311672v2 1 HP145-60-789834.v6 BLAKE ROAD STATION FIRST AMENDMENT TO PLANNED UNIT DEVELOPMENT AGREEMENT THIS FIRST AMENDMENT TO PLANNED UNIT DEVELOPMENT AGREEMENT (the “First Amendment”) is made this ___ day of _______________, 2022, by and between the CITY OF HOPKINS, a Minnesota municipal corporation, (the “City”), and TF Hopkins, LLC, a Delaware limited liability company (the “Developer”). WHEREAS, on October 5, 2021, the City and the Developer entered into that certain planned unit development agreement, which was filed with the Office of the Registrar of Titles for Hennepin County, Minnesota on December 1, 2021 as Document Number 5901954 (the “Agreement”); and WHEREAS, the Agreement contains various terms and conditions under which the Developer is to develop certain real property legally described therein (the “Property”); and WHEREAS, the Agreement generally only covers the first phase of the underlying multi- phase development and contemplates future amendments to accommodate subsequent phases; and WHEREAS, the Developer recently received conditional approval from the City for the site plan associated with the second phase, and so the parties desire to amend the Agreement in order to facilitate said second phase. NOW, THEREFORE, in consideration of the covenants and the mutual obligations contained herein, the City and the Developer hereby covenant and agree to amend and supplement the Agreement as follows: Section I. Recitals D, E, and G of the Agreement are hereby amended by adding the double- underlined language as follows: D. To accommodate the first phase of the Development, the City conditionally approved a planned unit development site plan for Lot 2, Block 1, Hopkins Commerce Center Addition, PID 19-117-21-42-0045 (the “Site Plan”) per Resolution 2021-043 (the “Site Plan Resolution”), adopted by the City Council on August 2, 2021, which is incorporated into this Agreement as if fully set forth herein. Said first phase includes a seven-story multi-use 73311672v2 2 HP145-60-789834.v6 facility containing approximately 220 apartment units and approximately 2,100 square feet of commercial space. To accommodate the second phase of the Development, the City conditionally approved a planned unit development site plan for Lot 3, Block 1, Hopkins Commerce Center Addition, PID 19-117-21-42-0046 (the “Phase II Site Plan” per Resolution 2022-031 (the “Phase II Site Plan Resolution”), adopted by the City Council on April 5, 2022, which is incorporated into this Agreement as if fully set forth herein. Said second phase includes a seven-story multi-use facility containing approximately 250 apartment units and approximately 10,000 square feet of commercial space. E. The Rezoning Ordinance, and the Site Plan Resolution, and the Phase II Site Plan Resolution shall be referred to collectively in this Agreement as the “City Approvals.” G. Although this Agreement contains certain terms and conditions that will obligate the parties with respect to certain elements of subsequent phases of the Development, it is expressly understood that the Site Plan Resolution, the Phase II Site Plan Resolution, this Agreement, and the PUD Declaration, as defined herein, are only intended to authorize the actual development of the Development’s first and second phases. The Developer shall be required to obtain site plan approvals for future phases of the Development and, should there be any necessary flexibility provided by the City for said future phases with respect to the City’s Mixed Use District standards, the PUD Declaration shall be amended accordingly. Subsequent planned unit development agreements or amendments to this Agreement may also be necessary, in the City’s discretion, at the time of future phases. Section II. Section 2.01 of the Agreement is hereby amended by adding the double-underlined language and deleting the stricken language as follows: 2.01. Private Improvements. In the first and second phases, the Developer shall construct and install, at the Developer's expense, the proposed seven-story multi-use facility containing approximately 220 apartment units and approximately 2,100 square feet of commercial space (the “Private Phase I Improvements”), and the proposed seven-story multi use facility containing approximately 250 apartment units and approximately 10,000 square feet of commercial space (the “Phase II Improvements” and collectively with the Phase I Improvements, the “Private Improvements”), according to the following terms and conditions: A. Plans. The Developer shall construct the Private Phase I Improvements in accordance with the City Approvals, including the approved Site Plan, and all associated construction plans and documentation (the “Phase I Plans”) on or before December 31, 2023. The Phase I Plans are those that are on file with the City, prepared by ESG Architecture & Design, dated June 25, 2021. The Developer shall construct the Phase II Improvements in accordance with the City Approvals, including the approved Phase II Site Plan, and all associated construction plans and documentation (the “Phase II Plans” and collectively with the Phase I Plans, the “Plans”) on or before December 31, 2024. The Phase II Plans are those that are on file with the City, prepared by ESG Architecture & Design, dated __________________, 2022. For the avoidance of doubt, the Plans include 73311672v2 3 HP145-60-789834.v6 the Developer’s required construction of the north-south private road from Excelsior Boulevard to at least the northern end of the approved structure on Site A, which is necessary to provide access to the structure contemplated during the second phase. No revisions to or deviations from the Plans that would materially alter the Private Improvements may occur unless first approved by the City in writing. B. Permits. The Developer shall secure all required permits necessary to construct the Private Improvements and provide documentation of such permits to the City, and nothing contained in this Agreement shall be deemed approval of or a substitute for any such permit. Section III. Section 2.03 of the Agreement is hereby amended by adding the double-underlined language and deleting the stricken language as follows: 2.03. Zoning/PUD. Pursuant to the Rezoning Ordinance, the Property was rezoned to Mixed Use/Planned Unit Development. In order to secure the benefits and advantages of the approved planned unit development, the Developer shall execute and record a one or more Declaration of Covenants, Conditions and Restrictions against the Property in the form attached hereto as Exhibits B and C (collectively, the “PUD Declaration”). Section IV. Section 2.08 of the Agreement is hereby amended by adding the double-underlined language and deleting the stricken language as follows: 2.08. Stormwater Management Requirements. As part of the Private Improvements, the Developer (or future owners/developers of the Property) shall be responsible for the construction, operation, and maintenance of stormwater management facilities to achieve compliance with applicable stormwater treatment requirements. The Developer (or future owners/developers of the Property) shall be required to execute and record a one or more (one for each phase) stormwater declarations in favor of the Minnehaha Creek Watershed District (“MCWD”) to the satisfaction of the MCWD for those stormwater facilities constructed as part of the Private Improvements. The purpose of the declarations is to ensure that the Developer, and future developers/owners of the Property, maintain the stormwater facilities. The declarations shall be recorded against the Property and will run with the land. The Developer acknowledges that i) the City will not accept ownership of the stormwater facilities; and ii) the City does not plan to maintain or pay for maintenance, repair or replacement of the stormwater facilities and that the Developer will have responsibility for such work. Section V. Section 2.09 of the Agreement is hereby amended by adding the double-underlined language and deleting the stricken language as follows: 2.09. Financial Guarantee. As part of the Plans, the Developer has agreed to install private landscaping/streetscaping on the Property (collectively, the “Secured Improvements”), which requires financial security to ensure that they are completed with the other Private Improvements. Prior to the issuance of any City-issued permits related to the Private Improvements, including, but not limited to, building permits, the Developer 73311672v2 4 HP145-60-789834.v6 agrees to deposit with Stewart Title Company, 333 South Seventh Street, Suite 2420, Minneapolis, Minnesota 55402 (the “Escrow Agent”) the amount of $282,500.00 $640,000.00 (the “Escrow Deposit”), which represents 125 percent of the estimated cost of the Secured Improvements associated with the first two phases. The Escrow Deposit shall be deposited with the Escrow Agent prior to beginning any work on the Private Improvements, except that the Phase I Improvements may commence upon the partial deposit of $282,500.00. The Developer and City shall enter into an escrow agreement with the Escrow Agent encompassing the terms of this Section 2.09 and which shall provide that the City may draw upon the Escrow Deposit, in whole or part, in order to complete construction of any or all of the Secured Improvements upon the Developer’s uncured default and failure to completed such Secured Improvements in accordance with the terms of this Agreement. The City may also draw upon the Escrow Deposit to pay any fees or costs owed to the City under this Agreement and otherwise unpaid by the Developer upon the lapse of all notice and cure rights of the Developer. It is the intention of the parties that the City at all times have available to it a Escrow Deposit in an amount adequate to ensure completion of the Secured Improvements and cost reimbursement to the City by the Developer as required under this Agreement. Upon the Developer’s failure to either complete the Secured Improvements, pay any fees or costs owed to the City under this Agreement, or both, the City may draw on the Escrow Deposit in order to satisfy such requirements but only after the Developer fails to cure its breach following sixty (60) days’ written notice from the City. In the event that the Escrow Deposit is found to be deficient in amount to pay or reimburse the City in total as required herein, the Developer agrees that upon being billed by the City, it will pay within thirty (30) days of the mailing of said billing, the said deficient amount. If there should be an overage in the amount of the utilized Escrow Deposit, the City will, upon making said determination, refund to the Developer any monies, without interest, which the City has in its possession which are in excess of the actual costs owed to the City hereunder. In the event the Developer files bankruptcy or in the event a bankruptcy proceeding is filed against Developer by others and is not dismissed within 90 days, or in the event a court appoints a receiver for the Developer, the City may draw on the Escrow Deposit in its full amount to secure its surety position. The City shall then release the remainder of said Escrow Deposit to the bankruptcy court or receiver in the same manner that it would be required to release the Escrow Deposit under this Agreement. When reasonably prudent, the Developer may request of the City that the Escrow Deposit be proportionately reduced for portions of completed obligations herein. All such reductions shall be in the sole discretion of the City. It is the intention of the parties that the City at all times have available to it an Escrow Deposit in an amount adequate to ensure completion of all elements of the Secured Improvements and the reimbursement of City costs required under this Agreement. To that end and notwithstanding anything herein to the contrary, all requests by the Developer for a reduction or release of the Escrow Deposit shall be evaluated by the City in light of that principle. The costs incurred by the City in processing any reduction request shall be billed to the Developer and paid to the City within 73311672v2 5 HP145-60-789834.v6 thirty (30) days of billing. Section VI. Section 2.24 of the Agreement is hereby amended by adding the double-underlined language and deleting the stricken language as follows: 2.24. City’s Access. The Developer hereby grants the City, its agents, employees, officers and contractors a non-revocable, non-exclusive, license to enter the Property to perform any work and inspections deemed appropriate by the City related to any of the Developer’s obligations contained in this Agreement. Such license shall terminate for each individual phase upon the issuance of a certificate of occupancy for the corresponding all improvements contemplated as part of the first phase this Agreement and the City’s final approval of the Secured Improvements. Section VII. The Agreement is hereby amended by adding a new Exhibit C, as attached hereto. [The remainder of this page to remain intentionally blank]. 73311672v2 6 HP145-60-789834.v6 IN WITNESS OF THE ABOVE, the parties have caused this First Amendment to be executed on the date and year written above. THE CITY: By: ____________________________________ Patrick Hanlon Mayor By: ____________________________________ Michael Mornson City Manager STATE OF MINNESOTA ) ) SS. COUNTY OF HENNEPIN ) The foregoing instrument was acknowledged before me this ___ day of ________________, 2022, by Patrick Hanlon and Michael Mornson, the Mayor and City Manager, respectively, of the City of Hopkins, a Minnesota municipal corporation, on behalf of the City. ____________________________________ Notary Public 73311672v2 7 HP145-60-789834.v6 THE DEVELOPER: TF HOPKINS LLC By: _______________________________ Its: _______________________________ STATE OF ILLINOIS ) ) SS. COUNTY OF ____________ ) The foregoing instrument was acknowledged before me this __ day of ________________, 2022, by ______________, the _______________ of TF Hopkins LLC, a Delaware limited liability company, by and on behalf of said company. __________________________________ Notary Public This document drafted by: KENNEDY & GRAVEN, CHARTERED 150 South 5th Street, Suite 700 Minneapolis, MN 55402 (612) 337-9300 73311672v2 C-1 HP145-60-789834.v6 EXHIBIT C FORM OF DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS BLAKE ROAD STATION (SITE B) PLANNED UNIT DEVELOPMENT THIS DECLARATION made this ___ day of ______________, 2022, by TF Hopkins, LLC, a Delaware limited liability company (hereinafter referred to as the “Declarant”); WHEREAS, Declarant is the owner of the real property as described below (hereinafter referred to as the “Subject Property”): Lot 3, Block 1, Hopkins Commerce Center Addition, Hennepin County, Minnesota; and WHEREAS, the Subject Property is subject to certain zoning and land use restrictions imposed by the City of Hopkins, Minnesota ("City") in connection with the approval of an application for a mixed-use planned unit development on the Subject Property and surrounding parcels; and WHEREAS, the City has approved the second phase of such development to be located on the Subject Property, including the required site plan approval, on the basis of the determination by the City Council of the City that such development is acceptable only by reason of the details of the development proposed and the unique land use characteristics of the proposed use of the Subject Property; and that but for the details of the development proposed and the unique land use characteristics of such proposed use, the planned unit development would not have been approved; and WHEREAS, as a condition of approval of the second phase of the planned unit development, the City has required the execution and filing of this Declaration of Covenants, Conditions and 73311672v2 C-2 HP145-60-789834.v6 Restrictions (hereinafter the “Declaration”); and WHEREAS, to secure the benefits and advantages of approval of such second phase, the Declarant desires to subject the Subject Property to the terms hereof. NOW, THEREFORE, the Declarant declares that the Subject Property is, and shall be, held, transferred, sold, conveyed and occupied subject to the covenants, conditions, and restrictions, hereinafter set forth. 1. The use and development of the Subject Property shall conform to the following documents, plans, drawings, and requirements: a. The plans (“Plans”), prepared by ESG Architecture & Design, dated __________________, 2022 and as may be amended pursuant to any City-imposed conditions, the sheets of which are specified on Attachment One hereof. Original documents are on file with the City and are made a part hereof. It is expressly acknowledged and understood that the second phase is referenced in said Plans as “Site B,” and this Declaration only relates to said Site B. b. In exchange for the flexibility provided by the City as part of the approved planned unit development to be located on the Subject Property, the Developer has agreed to provide the elements contained in the Plans, as related to Site B, including, but not necessarily limited to, densities that are more transit-supportive and more consistent with the City’s 2040 Comprehensive Plan than the City’s Mixed Use District requirements; enhanced stormwater management; a public linear park; designated outdoor pet areas; bicycle amenities; enhanced landscaping, including, but certainly not limited to, greenwall features on north and west sides of structure; and 20 electric vehicle charging stations located in the parking lot. c. The improvements on the Subject Property will be constructed so that they are solar-ready in the event it is deemed practical to install photovoltaic panels in the future. 73311672v2 C-3 HP145-60-789834.v6 d. The improvements on the Subject Property will maintain enrollment in the Xcel Energy Efficient Building Program or similar program (EEB) unless and until said program is otherwise terminated or no longer available at the Subject Property. 2. The Subject Property may only be developed and used in accordance with all requirements of the City’s Mixed Use District, except for those deviations contained in the Plans or otherwise outlined herein, and all other requirements contained in Paragraph 1 of this Declaration, unless the then-owner of the Subject Property first secures approval by the City Council of an amendment to the planned unit development plan or a rezoning to a zoning classification that permits such other development and use. 3. In connection with the approval of development of the Subject Property (Site B), the following deviations from the City’s land use regulations, to the extent contained in the Plans, were approved: PUD Approved Deviations on Subject Property (Site B) Category Mixed Use Requirement Approved Deviation for PUD Building Height 6 Stories 7 Stories Floor to Area Ratio 3.0 2.8 Setback (North) 10’ 5’-3” to 20’-7 Setback (South) 15’ – 25’ 10’-8” to 18’-2” Setback (East) 15’ – 25’ 9’-8” to 28’-5” Setback (West) 15’ – 25’ 32’-8” to 49’-10” Parking Stall Dimensions 9’ X 20’ As contained in Plans (Site B) Exterior Building Materials >80% Primary Exterior Treatment As Contained in Plans (Site B) Building Transparency 60% transparency between 2 ft and 8 ft As contained in Plans (Site B) Building Façade Articulation 25’ – 40’ As Contained in Plans (Site B) Signage One monument sign permitted One monument sign (size allowed shown on sheet A3-1 of Plans) allowed in addition to the existing Goodwill sign at southwest corner of Site B 73311672v2 C-4 HP145-60-789834.v6 In all other respects the use and development of the Subject Property shall conform to the requirements of the Paragraphs 1 and 2 of this Declaration and the City Code of Ordinances. 4. The obligations and restrictions of this Declaration run with the land of the Subject Property and shall be enforceable against the Declarant, its successors and assigns, which successors and assigns shall be jointly and severally responsible for obligations under this Declaration, by the City of Hopkins acting through its City Council. This Declaration may be amended from time to time by a written amendment executed by the City and the owner or owners of the lot or lots to be affected by said amendment. [signature page to follow] 73311672v2 C-5 HP145-60-789834.v6 IN WITNESS WHEREOF, the undersigned as duly authorized agents, officers or representatives of Declarant have hereunto set their hands and seals as of the day and year first above written. DECLARANT: TF HOPKINS LLC By: _______________________________ Its: _______________________________ STATE OF ILLINOIS ) ) SS. COUNTY OF ____________ ) The foregoing instrument was acknowledged before me this __ day of ________________, 2022, by ______________, the _______________ of TF Hopkins LLC, a Delaware limited liability company, by and on behalf of said company. __________________________________ Notary Public This document drafted by: KENNEDY & GRAVEN, CHARTERED 150 South 5th Street, Suite 700 Minneapolis, MN 55402 (612) 337-9300 C-A-1 HP145-60-789834.v6 Attachment One The following documents prepared by ESG Architecture & Design, as revised ____________________, 2022, and to the extent that they address Site B, collectively constitute the Plans: Signature Typed or Printed Name License #Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/17/2022 11:48:24 AMT1-1 TITLE SHEET 221561.00 Author Checker 02/18/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 PROJECT TEAMPROJECT LOCATION DRAWING INDEX Blake Station Site B Hopkins, MN 8490 Excelsior Boulevard Vicinity Site Location DRAWING INDEX DRAWING NUMBER DRAWING NAME LUA 2/18/2022GENERAL INFORMATION T1-1 TITLE SHEET ● T1-2 CONTEXT MAP & IMAGES ● T1-3 MASTER PLAN ● CIVIL C200 DEMOLITION PLAN ● C300 EROSION AND SEDIMENT CONTROL PLAN – PHASE 1 ● C301 EROSION AND SEDIMENT CONTROL PLAN – PHASE 2 ● C401 SITE PLAN – SITE B ● C501 GRADING PLAN – SITE B ● C503 STORM SEWER PLAN – SITE B ● C601 UTILTIY PLAN – SITE B ● V100 EXISTING CONDITIONS SURVEY ● LANDSCAPE L010 GENERAL NOTES ● L011 REFERENCE NOTES & PLANTING SCHEDULES ● L100 OVERALL SITE PLAN ● L111 SITE PLAN BUILDING B ● L140 LANDSCAPE PLAN - BUILDING B ● L400 LANDSCAPE SECTIONS ● L500 LANDSCAPE DETAILS ● ARCHITECTURAL A1-0 LEVEL P1 PLAN ● A1-1 LEVEL 1 PLAN ● A1-2 LEVEL 2 PLAN ● A1-3 LEVEL 3 PLAN ● A1-4 LEVEL 4-6 PLAN ● A1-5 LEVEL 7 PLAN ● A1-6 ROOF PLAN ● A3-1 PERSPECTIVE VIEWS ● A3-2 SOUTH AND EAST BUILDING ELEVATIONS ● A3-3 WEST AND NORTH BUILDING ELEVATIONS ● A3-4 EXTERIOR MATERIALS ● A3-5 SHADOW STUDIES ● ELECTRICAL E0.1P ELECTRICAL SITE PHOTOMETRIC ● E0.2P ELECTRIC SITE PHOTOMETRIC DETAILS ● E0.3P ELECTRIC SITE PHOTOMETRIC DETAILS ● E0.4P ELECTRIC SITE PHOTOMETRIC DETAILS ● UNIT MIX & BUILDING DATA OWNER/DEVELOPER:Trilogy Real Estate Group, LLC 520 West Erie Street Suite 100 Chicago, IL 60654 Ph: (312) 750-0900 Ext. 125 ARCHITECT:Elness Swenson Graham Architects, Inc. 500 Washington Ave. South, Suite 1080 Minneapolis, MN 55415 Ph: 612-339-5508 Fx: 612-339-5382 CIVIL ENGINEER:Kimley-Horn 767 N Eustis Street, Suite 100 St. Paul, MN 55114 Ph: 651-645-4197 LANDSCAPE ARCHITECT:Damon Farber Landscape Architects 310 S 4th Ave, Suite 7050 Minneapolis, MN 55415 Ph: 612-332-7522 STRUCTURAL ENGINEER:Meyer Borgman Johnson 510 S Marquette Ave Unit 900 Minneapolis, MN 55402 Ph: 612-338-0713 MEP ENGINEERING:Emanuelson-Podas, Inc. 7705 Bush Lake Road Edina, MN 55439 Ph: 952-930-0050 **UNIT MIX SUMMARY - OPTION 1) Name Qty % Area Min - Max SF 1 BED 97 39% 66,839 SF 645 SF ... 720 SF 1 BED + DEN 2 1% 1,572 SF 774 SF ... 797 SF 2 BED 80 32% 81,097 SF 904 SF ... 1,052 SF 3 BED 11 4% 14,087 SF 1,272 SF ... 1,318 SF ALCOVE 40 16% 21,656 SF 495 SF ... 597 SF STUDIO 20 8% 9,650 SF 464 SF ... 521 SF Grand total: 250 250 194,900 SF BUILDING GROSS BUILDING Level Area LEVEL P1 66,337 SF LEVEL 1 64,904 SF LEVEL 2 65,004 SF LEVEL 3 42,027 SF LEVEL 4 41,828 SF LEVEL 5 41,828 SF LEVEL 6 41,828 SF LEVEL 7 40,812 SF 404,569 SF RESIDENTIAL GROSS AREA Level Area LEVEL 2 19,615 SF LEVEL 3 38,269 SF LEVEL 4 40,842 SF LEVEL 5 40,842 SF LEVEL 6 40,842 SF LEVEL 7 38,742 SF 219,153 SF PARKING GROSS AREA Level Area LEVEL P1 62,469 SF LEVEL 1 39,478 SF LEVEL 2 42,751 SF 144,697 SF PARKING SCHEDULE - VEHICLES Description Count LEVEL P1 8 x 18 COMPACT 7 9'-0" x 16' COMPACT 3 ACCESSIBLE STALL 4 COMPACT 8 STANDARD 126 LEVEL 1 8 x 18 COMPACT 3 8'-6" x 18' STANDARD 3 9'-0" x 16' COMPACT 3 9'-0" x 18' STANDARD 1 ACCESSIBLE STALL 4 COMPACT 1 STANDARD 71 LEVEL 2 8 x 18 COMPACT 6 9'-0" x 16' COMPACT 2 ACCESSIBLE STALL 4 COMPACT 5 STANDARD 88 TOTAL STALLS:339 No. Description Date Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:31 PMT1-2 CONTEXT MAP & IMAGES 221561.00 Author Checker 02/11/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 No. Description Date Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:32 PMT1-3 MASTER PLAN 221561.00 Author Checker 02/11/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 NORTH PLAN No. Description Date 0 4020 80 MASTER PLAN SITE A SITE B SITE C EXCELSIOR BL V D BLAKE ROAD S(CO. RD. NO. 3 )(CO. RO. NO. 20)(PUBLIC)(PUBLIC)DDDD D D D 8,571 SF AMENITY 2,840 SF RETAIL 3,222 SF RETAIL 832 SF AMENITY 4,000 SF RETAIL 556 SF COMMON / CIRCULATION 77 SF COMMON / CIRCULATION 152 SF BOH 452 SF MECH / ELEC 304 SF COMMON / CIRCULATION 21,298 SF PARKING 18,180 SF PARKING 374 SF STORAGE 143 SF COMMON / CIRCULATION 776 SF BOH 370 SF BOH 568 SF BOH 217 SF BOH CIRC PROPOSED BUILDING B FFE: 915.10 TO 920.00 P1 FFE: ±909.091891891891 7 91 8 917 9 1 7 918 919 920919918917916915 91 5 91 6 9 1 7 918919919919 919 918 918 919917917918917916 917DISCHARGE LOCATION #1 EXCELSIOR AVE. STORM SEWER DISCHARGE LOCATION #2 BLAKE ROAD S. STORM SEWER B B C C B D D D D D D DD D C D D B C C A C Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed engineer under the laws of the State of Minnesota 7/17/2020160573033 BPG BLAKE ROAD STATION - SITE B BLAKE STATION SITE B Hopkins, MN 2/18/2022 No. Description Date 2022 KIMLEY-HORN AND ASSOCIATES, INC. 767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114 PHONE: 651-645-4197 WWW.KIMLEY-HORN.COM XX/XX/XXXX WDM LUA SUBMITTAL 12/14/2021 WILLIAM D. MATZEK 42661 NORTH EROSION CONTROL PLAN NOTES 1. ALL PERIMETER SILT FENCE AND ROCK CONSTRUCTION ENTRANCES SHALL BE INSTALLED PRIOR TO CONSTRUCTION. 2. THE CONTRACTOR SHALL CONSTRUCT DRAINAGE BASINS PRIOR TO SITE GRADING. 3. THE CONTRACTOR SHALL INSTALL CATCH BASIN EROSION CONTROL MEASURES. 4. WITHIN TWO WEEKS (14 DAYS) OF SITE GRADING, ALL DISTURBED AREAS SHALL BE STABILIZED WITH SEED, SOD, OR ROCK BASE. REFER TO LANDSCAPE PLANS FOR MATERIALS. 5. ALL EROSION CONTROL MEASURES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH CITY, STATE, AND WATERSHED DISTRICT PERMITS. 6. THE CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL MEASURES, INCLUDING THE REMOVAL OF SILT IN FRONT OF SILT FENCES DURING THE DURATION OF THE CONSTRUCTION. 7. ANY EXCESS SEDIMENT IN PROPOSED BASINS SHALL BE REMOVED BY THE CONTRACTOR. 8. REMOVAL ALL EROSION CONTROL MEASURES AFTER VEGETATION IS ESTABLISHED. 9. THE CONTRACTOR SHALL REMOVE ALL SOILS AND SEDIMENT TRACKED ONTO EXISTING STREETS AND PAVED AREAS AND SHALL SWEEP ADJACENT STREETS AS NECESSARY IN ACCORDANCE WITH CITY REQUIREMENTS. 10. IF BLOWING DUST BECOMES A NUISANCE, THE CONTRACTOR SHALL APPLY WATER FROM A TANK TRUCK TO ALL CONSTRUCTION AREAS. UPON IMPLEMENTATION AND INSTALLATION OF THE FOLLOWING AREAS: TRAILER, PARKING, LAYDOWN, PORTA-POTTY, WHEEL WASH, CONCRETE WASHOUT, FUEL AND MATERIAL STORAGE CONTAINERS, SOLID WASTE CONTAINERS, ETC., IMMEDIATELY DENOTE THEM ON THE SITE MAPS AND NOTE ANY CHANGES IN LOCATION AS THEY OCCUR THROUGHOUT THE CONSTRUCTION PROCESS. BMP AND EROSION CONTROL INSTALLATION SEQUENCE SHALL BE AS FOLLOWS: 1. TEMPORARILY SEED, THROUGHOUT CONSTRUCTION, DENUDED AREAS THAT WILL BE INACTIVE FOR 7 DAYS OR MORE. 2. INSTALL UTILITIES, UNDERDRAINS, STORM SEWERS, UNDERGROUND SYSTEM, CURBS AND GUTTERS. 3. INSTALL APPROPRIATE INLET PROTECTION AT ALL STORM SEWER STRUCTURES AS EACH INLET STRUCTURE IS INSTALLED. 4. PERMANENTLY STABILIZE AREAS TO BE VEGETATED AS THEY ARE BROUGHT TO FINAL GRADE. 5. PREPARE SITE FOR PAVING. 6. PAVE SITE AND INSTALL STRIPING. 7. INSTALL APPROPRIATE INLET PROTECTION DEVICES FOR PAVED AREAS AS WORK PROGRESSES. 8. COMPLETE GRADING AND INSTALLATION OF PERMANENT STABILIZATION OVER ALL AREAS. 9. OBTAIN CONCURRENCE WITH THE CIVIL ENGINEERING CONSULTANT THAT THE SITE HAS BEEN FULLY STABILIZED THEN: 1. REMOVE ALL REMAINING TEMPORARY EROSION ADN SEDIMENT CONTROL DEVICES 2. STABILIZE ANY AREAS DISTURBED BY THE REMOVAL OF BMPS. SEQUENCE OF CONSTRUCTION: ROCK ENTRANCE INLET PROTECTION SILT FENCE LIMITS OF DISTURBANCE SAFETY FENCE BIOROLL LEGEND EROSION CONTROL BLANKET KEYNOTE LEGEND CONSTRUCTION ENTRANCE LIMITS OF DISTURBANCE, OFFSET FOR CLARITY BIROLL INLET PROTECTION BIOLOG A B C D E BMP QUANTITIES BMP UNIT QUANTITY CONSTRUCTION ENTRANCE EA.1 BIROLL LF 1,275 INLET PROTECTION EA.12 C301 EROSION AND SEDIMENT CONTROL PLAN - PHASE 2C301 EROSION AND SEDIMENT CONTROL PLAN - PHASE 2 EXCELSIOR BL V D BLAKE ROAD S(CO. RD. NO. 3 )(CO. RO. NO. 20)(PUBLIC)(PUBLIC)W C A R PROPOSED BUILDING B FFE: 919.25 TO 920.0 P1 FFE: ±909.0 8,571 SF AMENITY 2,840 SF RETAIL 3,222 SF RETAIL 832 SF AMENITY 4,000 SF RETAIL 556 SF COMMON / CIRCULATION 77 SF COMMON / CIRCULATION 152 SF BOH 452 SF MECH / ELEC 304 SF COMMON / CIRCULATION 21,298 SF PARKING 18,180 SF PARKING 374 SF STORAGE 143 SF COMMON / CIRCULATION 776 SF BOH 370 SF BOH 568 SF BOH 217 SF BOH CIRC PROPOSED BUILDING B FFE: 915.10 TO 920.00 P1 FFE: ±909.0 G G A R R C E F H J J J J J J L1 L1 L1 L2 Q T T F T L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 B B B D T AA AA 6.0'6.0'24.0' 16.0' 7.7' 12.3' (TYP.) 6.0'4.0'6.0'10.0' 6.0'6.0' 6.0'6.0'6.4'5.0' 7.5' 5.0'3.5' 10.0'5.0'3.2'15.4'5.0'J J Z 11.4'6.0' 10.1'6.0' 11.0'6.0' L2 J L1 PROPOSED 6' LANDSCAPED BOULEVARD AND 10' MIN. TRAIL/SIDEWALK ALONG BLAKE ROAD S. L1 L2 11.6' 19.0' 6.0' 24.0' BB VARIABLE HEIGHT CURB FROM SIDEWALK TO PROPERTY LINE - SEE SHEET C501 FOR GRADING DETAILS 8.0' 18.0' L1 L1 L1 L1 L1 FUTURE DRIVEWAY ACCESS TO PARKING GARAGE 5.0'10.0'CC DD DD EE EE L1 L2 I S S I I I I BB F F Y Y H D D D D RECESSED RETAIL ENTRY RECESSED AMENITY ENTRY RECESSED PARKING ENTRY RECESSED RETAIL ENTRY RETAIL ENTRY RESIDENTIAL ENTRY RESIDENTIAL ENTRY PARKING ENTRY PARKING ENTRY PROPOSED POCKET PARK, SEE LANDSCAPE PLANS M N O K K DD W P Y Y Y EXISTING DRIVEWAY ACCESS PROPOSED CURB AND GUTTER PROPERTY LINE RETAINING WALL PROPOSED STANDARD DUTY ASPHALT PROPOSED CONCRETE PAVEMENT LEGEND PROPOSED LANDSCAPING, SEE LANDSCAPE PLAN Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed engineer under the laws of the State of Minnesota 7/17/2020160573033 BPG BLAKE ROAD STATION - SITE B BLAKE STATION SITE B Hopkins, MN 2/18/2022 No. Description Date 2022 KIMLEY-HORN AND ASSOCIATES, INC. 767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114 PHONE: 651-645-4197 WWW.KIMLEY-HORN.COM XX/XX/XXXX WDM LUA SUBMITTAL 12/14/2021 WILLIAM D. MATZEK 42661 SITE PLAN NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY REGULATIONS AND CODES AND O.S.H.A. STANDARDS. 2. CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. 3. ALL DIMENSIONS AND RADII ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 4. EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE ABANDONED, REMOVED OR RELOCATED AS NECESSARY. ALL COST SHALL BE INCLUDED IN BASE BID. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, (UNLESS OTHERWISE NOTED ON PLANS) INCLUDING BUT NOT LIMITED TO, ALL UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS REQUIRED. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING AUTHORITIES REQUIREMENTS AND PROJECT SITE WORK SPECIFICATIONS AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE BID. 6. SITE BOUNDARY, TOPOGRAPHY, UTILITY AND ROAD INFORMATION TAKEN FROM A SURVEY BY SAMBATEK, DATED 02/12/2020. KIMLEY-HORN ASSUMES NO LIABILITY FOR ANY ERRORS, INACCURACIES, OR OMISSIONS CONTAINED THEREIN. 7. CONTRACTOR SHALL REFERENCE ARCH / MEP PLANS FOR SITE LIGHTING AND ELECTRICAL PLAN. 8. NO PROPOSED LANDSCAPING SUCH AS TREES OR SHRUBS, ABOVE AND UNDERGROUND STRUCTURES, OR OTHER OBSTRUCTIONS SHALL BE LOCATED WITHIN EXISTING OR PROPOSED UTILITY EASEMENTS AND RIGHTS OF WAY UNLESS SPECIFICALLY NOTED ON PLANS OTHERWISE. 9. REFER TO FINAL PLAT OR ALTA SURVEY FOR EXACT LOT AND PROPERTY BOUNDARY DIMENSIONS. 10. ALL AREAS ARE ROUNDED TO THE NEAREST SQUARE FOOT. 11. ALL DIMENSIONS ARE ROUNDED TO THE NEAREST TENTH FOOT. NORTH PROPERTY SUMMARY BLAKE & EXCELSIOR - SITE B TOTAL PROPERTY AREA 7.39 AC RIGHT OF WAY DEDICATION 0.00 AC BUILDING A PARCEL 1.62 AC BUILDING B PARCEL 2.27 AC BUILDING C PARCEL (FUTURE)3.50 AC PROPOSED IMPERVIOUS AREA (BUILDING B PARCEL)85,393 SF (1.96 AC) PROPOSED PERVIOUS AREA (BUILDING B PARCEL)8,939 SF (0.21 AC) TOTAL DISTURBED AREA (INCLUDES OFFSITE IMPROVEMENTS) 98,331 SF (2.26 AC) ZONING SUMMARY EXISTING ZONING B-3 GENERAL BUSINESS PROPOSED ZONING PUD C401SITE PLAN - SITE B PROPOSED CONCRETE SIDEWALK KEYNOTE LEGEND B612 CURB AND GUTTER STANDARD DUTY ASPHALT PAVEMENT PROPOSED STOOP/STAIRS/RISERS, REFERENCE ARCHITECTURAL PLANS FOR DETAILS ACCESSIBLE CURB RAMP PROPOSED GARAGE DOOR, REFERENCE ARCHITECTURAL PLANS FOR DETAILS PROPOSED BENCH/SITE FURNITURE, REFERENCE GRADING PLAN FOR ELEVATIONS AND LANDSCAPE PLANS FOR DETAILS PROPOSED TRANSFORMER PAD, UTILITY SCREEN/ENCLOSURES, REFERENCE ARCHITECTURAL PLANS FOR DETAILS PROPOSED PLANTER BED, REFERENCE LANDSCAPE ARCHITECTURAL PLANS FOR DETAILS PROPOSED STREET LIGHT, REFERENCE LIGHTING PLANS FOR DETAILS PROPOSED SIDEWALK RELOCATED TRAFFIC SIGN, SEE DEMO PLAN FOR EXISTING LOCATIONS PROPOSED LANDCAPE AREA, REFERENCE LANDSCAPE ARCHITECTURAL PLANS FOR DETAILS PROPOSED HARDSCAPE AREA, REFERENCE LANDSCAPE ARCHITECTURAL PLANS FOR DETAILS PET RELIEF AREA, SEE ARCH PLANS RAISED STAGE FEATURE, SEE LANDSCAPE PLANS EXISTING TRAFFIC SIGN TO REMAIN PROPOSED FENCE EXHAUST WELL, SEE ARCH PLANS SAWCUT LINE/MATCH EXISTING PAVEMENT SALVAGED AND RELOCATED STREET LIGHT - CONTRACTOR TO SALVAGE AND PROVIDE LIGHT POLES TO CITY FOR STORAGE, CONSTRUCT LIGHT POLE BASES AND PROVIDE CONDUIT WIRING, REINSTALL LIGHT POLES PROPOSED RETAINING WALL, REFERENCE GRADING PLAN FOR ELEVATION DETAILS AND LANDSCAPE PLANS FOR WALL TYPE FIRE LANE SIGN, SEE DETAIL NOT USED CONCRETE PAVEMENT DRIVEWAY ENTRANCE SALVAGE AND RELOCATE EXISTING BENCH PROPOSED BIKE RACKS, REFERENCE ARCHITECTURAL PLANS FOR DETAILS B624 CURB AND GUTTER PROPOSED BOLLARD PROPOSED MONUMENT SIGNAGE, REFERENCE ARCHITECTURAL PLANS SURMOUNTABLE B612 CURB TRANSITION CURB CRUSHED STONE LANDSCAPED AREA, REFERENCE LANDSCAPE PLANS FOR DETAILS A B C D E F G H I J K L1 L2 M N O P Q R S T U V W X Y Z AA BB CC DD EE PROPOSED HARDSCAPE, SEE LANDSCAPE PLANS PROPOSED CRUSHED STONE LANDSCAPING, SEE LANDSCAPE PLAN EXCELSIOR BL V D BLAKE ROAD S(CO. RD. NO. 3 )(CO. RO. NO. 20)(PUBLIC)(PUBLIC)DDD PROPOSED BUILDING B FFE: 919.25 TO 920.0 P1 FFE: ±909.0 8,571 SF AMENITY 2,840 SF RETAIL 3,222 SF RETAIL 832 SF AMENITY 4,000 SF RETAIL 556 SF COMMON / CIRCULATION 77 SF COMMON / CIRCULATION 152 SF BOH 452 SF MECH / ELEC 304 SF COMMON / CIRCULATION 21,298 SF PARKING 18,180 SF PARKING 374 SF STORAGE 143 SF COMMON / CIRCULATION 776 SF BOH 370 SF BOH 568 SF BOH 217 SF BOH CIRC PROPOSED BUILDING B FFE: 915.10 TO 920.00 P1 FFE: ±909.0 917916915 916 917 918 915 91 7 91791891891792092091991 9 919 9199 1 9 91 6 916 9 1 5 915914 920 9199 1 8 91791 6 9 1 5 91 6 917 918918 919916918919917918919917 919 918 918918918 918917 917 918 918918 9199179 1 7918 918 917918917916 916919918917916917 918 919 920 921922 917917 918 919919 918 9 1 9919919918917916 9199 1 8919 916 917 918 919 919 919919920917918919916FFE:917.25 FFE:919.25 FFE:919.25 FFE:919.25 FFE:919.25 FFE:917.90 FFE:916.50 FFE:916.50 FFE:915.50 FFE:920.00 FFE:920.00 T/G:915.85 T/G:915.84 916.30 916.31 T/G:916.09 916.58 916.65 T/G:916.16 T/G:916.81 T:916.72 G:916.27 T/G:917.27 T:917.21 G:916.71 G:916.76 T:917.26 T:916.67 917.52 916.88 916.98 919.00 917.14 916.93 916.77 916.67 916.74 916.40 916.89 916.98 T:916.43 G:915.93 T:916.50 917.00 ME:917.46 ME:917.17 ME/T:917.02 ME/G:916.52 916.63 ME:914.85 ME:915.04 ME:916.26 ME:917.58 ME:917.90 FFE:918.00 ME:916.47 T:916.47 G:915.97 T:917.60 G:917.10 ME:917.70 ME:918.44 ME:919.00 ME:919.02 ME:914.52 ME:914.59 ME/G:918.94 ME:915.40 918.00 916.00 915.00915.00 915.00 919.29 919.19 TW:919.25 BW:918.30 ME:918.24 919.33 918.05 918.52 918.47 917.52 919.25 918.01917.72 917.63 918.23 918.37 918.99 918.93 919.08 916.66 917.88 FFE:916.50 3.84%1.50% 5.74% 5.20% 23.81% 5.37% 7.70%2.23% 1.71% 8.10% 1.57% 1.51% 1.34 %1.94%1.61%1.93%1.50%1.76%1.41%1.95%2.84%4.05%3.89%1.94%4.71%6.51%3.67%1.38%6.97% 3.61% 2. 4 4% 1.96% 1.53% FFE:915.00 917.35917.21 916.94 G:916.17 920.00 919.92 ME:919.38 ME:919.49 4.73%1.81% 3.35% 5.9 6 %7.90%917.03 1.58%1.53%1.65% 917917 919 T:919.83 919.85 T:919.17 ME/G:917.94 T:919.18 T:918.40 ME/G:917.87 ME/T/G:917.61 917.07916.96 917.10 916.85 G:916.34 919.00 919.00 916.93916.70 2.50% 2.53% 918.76 918.82 3.12%3.35% 919.17 919.17 919.25 1.50% THREE - 6" RISERS THREE - 6" RISERS UNDERGROUND STORM SEWER SYSTEM, SEE SHEET C503 FOR DETAILS UNDERGROUND STORM SEWER SYSTEM, SEE SHEET C503 FOR DETAILS 91 5 91 6 9 1 7 918918 91 9 919915 916 917 918919917918919 ME:917.36 ME:917.52 ME:917.62 ME:917.46 917.90 917.90 917.73 917.73 916.50 ME:916.26 916.50 916.50 ME:916.23 ME:916.09916.50 915.50 915.50 ME:915.24 ME:915.39 1.50% 1.50% 1.50% ME:918.03 2.46%2.00% 916.34 916.35 916.35 916.35 2.02% 1.76% 1.50% 3.85% 4.14%3.17%915.43 915.33 0.77%1.32%2.05%2.01 % 914.88 ME:914.75 4.10%914.92 914.92 914.72 914.66 ME T/G:919.13 914.85 915.00 915.00 ME:914.67 ME:918.64 ME:918.85 ME:918.84 ME:918.78 Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed engineer under the laws of the State of Minnesota 7/17/2020160573033 BPG BLAKE ROAD STATION - SITE B BLAKE STATION SITE B Hopkins, MN 2/18/2022 No. Description Date 2022 KIMLEY-HORN AND ASSOCIATES, INC. 767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114 PHONE: 651-645-4197 WWW.KIMLEY-HORN.COM XX/XX/XXXX WDM LUA SUBMITTAL 12/14/2021 WILLIAM D. MATZEK 42661 GRADING PLAN NOTES 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY OF HOPKINS, SPECIFICATIONS AND BUILDING PERMIT REQUIREMENTS. 2. CONTRACTOR TO CALL GOPHER STATE CALL ONE @ <1-800-252-1166> AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATION/CONSTRUCTION FOR UTILITY LOCATIONS. 3. STORM SEWER PIPE SHALL BE AS FOLLOWS: RCP PER ASTM C-76 HDPE: 0" - 10" PER AASHTO M-252 HDPE: 12" OR GREATER PER ASTM F-2306 PVC SCH. 40 PER ASTM D-3034 STORM SEWER FITTINGS SHALL BE AS FOLLOWS: RCP PER ASTM C-76, JOINTS PER ASTM C-361, C-990, AND C-443 HDPE PER ASTM 3212 PVC PER ASTM D-3034, JOINTS PER ASTM D-3212 4. CONTRACTOR TO FIELD VERIFY THE LOCATIONS AND ELEVATIONS OR EXISTING UTILITIES AND TOPOGRAPHIC FEATURES PRIOR TO THE START OF SITE GRADING. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE PROJECT ENGINEER OF ANY DISCREPANCIES OR VARIATIONS. 5. SUBGRADE EXCAVATION SHALL BE BACKFILLED IMMEDIATELY AFTER EXCAVATION TO HELP OFFSET ANY STABILITY PROBLEMS DUE TO WATER SEEPAGE OR STEEP SLOPES. WHEN PLACING NEW SURFACE MATERIAL ADJACENT TO EXISTING PAVEMENT, THE EXCAVATION SHALL BE BACKFILLED PROMPTLY TO AVOID UNDERMINING OF EXISTING PAVEMENT. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL. 7. CONTRACTOR SHALL EXCAVATE DRAINAGE TRENCHES TO FOLLOW PROPOSED STORM SEWER ALIGNMENTS. 8. GRADES SHOWN ARE FINISHED GRADES. CONTRACTOR SHALL ROUGH GRADE TO SUBGRADE ELEVATION AND LEAVE STREET READY FOR SUBBASE. 9. ALL EXCESS MATERIAL, BITUMINOUS SURFACING, CONCRETE ITEMS, ANY ABANDONED UTILITY ITEMS, AND OTHER UNSTABLE MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OFF THE CONSTRUCTION SITE. 10. REFER TO THE UTILITY PLAN FOR SANITARY SEWER MAIN, WATER MAIN SERVICE LAYOUT AND ELEVATIONS AND CASTING / STRUCTURE NOTATION. 11. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION OF PAVEMENTS AND CURB AND GUTTER WITH SMOOTH UNIFORM SLOPES TO PROVIDE POSITIVE DRAINAGE. 12. INSTALL A MINIMUM OF 4" CLASS 5 AGGREGATE BASE UNDER CURB AND GUTTER AND CONCRETE SIDEWALKS. 13. UPON COMPLETION OF EXCAVATION AND FILLING, CONTRACTOR SHALL RESTORE ALL STREETS AND DISTURBED AREAS ON SITE. ALL DISTURBED AREAS SHALL BE RE-VEGETATED WITH A MINIMUM OF 6" OF TOPSOIL. 14. ALL SPOT ELEVATIONS/CONTOURS ARE TO GUTTER / FLOW LINE UNLESS OTHERWISE NOTED. 15. GRADING FOR ALL SIDEWALKS AND ACCESSIBLE ROUTES INCLUDING CROSSING DRIVEWAYS SHALL CONFORM TO CURRENT ADA STATE/NATIONAL STANDARDS. IN NO CASE SHALL ACCESSIBLE RAMP SLOPES EXCEED 1 VERTICAL TO 12 HORIZONTAL. IN NO CASE SHALL SIDEWALK CROSS SLOPES EXCEED 2% . IN NO CASE SHALL LONGITUDINAL SIDEWALK SLOPES EXCEED 5%. IN NO CASE SHALL ACCESSIBLE PARKING STALLS OR AISLES EXCEED 2% (1.5% TARGET) IN ALL DIRECTIONS. SIDEWALK ACCESS TO EXTERNAL BUILDING DOORS AND GATES SHALL BE ADA COMPLIANT. CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF ADA CRITERIA CANNOT BE MET IN ANY LOCATION PRIOR TO PAVING. NO CONTRACTOR CHANGE ORDERS WILL BE ACCEPTED FOR A.D.A COMPLIANCE ISSUES. 16. MAINTAIN A MINIMUM OF 0.5% GUTTER SLOPE TOWARDS LOW POINTS. 17. CONTRACTOR TO PROVIDE 3" INSULATION BY 5' WIDE CENTERED ON STORM PIPE IF LESS THAN 4' OF COVER IN PAVEMENT AREAS AND LESS THAN 3' OF COVER IN LANDSCAPE AREAS. 18. ROOF DRAIN INVERT CONNECTIONS AT THE BUILDING SHALL BE AT ELEVATION <XXX.XX> OR LOWER UNLESS NOTED OTHERWISE. REFERENCE MEP PLANS FOR ROOF DRAIN CONNECTION. 19. ALL STORM SEWER CONNECTIONS SHALL BE GASKETED AND WATER TIGHT INCLUDING MANHOLE CONNECTIONS. 20. ALL STORM SEWER PIPE SHALL BE AIR TESTED IN ACCORDANCE WITH THE CURRENT PLUMBING CODE. 21. MAINTAIN A MINIMUM OF 1.25% SLOPE IN BITUMINOUS PAVEMENT AREAS, 0.5% SLOPE IN CONCRETE PAVEMENT AREAS. 22. CONTRACTOR SHALL REVIEW PAVEMENT GRADIENT AND CONSTRUCT "INFALL CURB" WHERE PAVEMENT DRAINS TOWARD GUTTER, AND "OUTFALL" CURB WHERE PAVEMENT DRAINS AWAY FROM GUTTER. PROPOSED STORM SEWER PROPOSED STORM SEWER PROPERTY LINE EXISTING CONTOUR PROPOSED CONTOUR925 PROPOSED SPOT ELEVATION100.00 LEGEND PROPOSED HIGH POINT ELEVATION HP:0.0 PROPOSED LOW POINT ELEVATION PROPOSED GUTTER ELEVATION PROPOSED TOP OF CURB ELEVATION PROPOSED FLUSH PAVEMENT ELEVATION LP:0.0 G:0.00 T:0.00 PROPOSED EMERGENCY OVERFLOW T/G:0.0 EOF:0.0 0.0%PROPOSED DRAINAGE DIRECTION 0.00%PROPOSED ADA SLOPE ME:0.0 MATCH EXISTING ELEVATION PROPOSED STORM MANHOLE (SOLID CASTING) PROPOSED STORM MANHOLE (ROUND INLET CASTING) PROPOSED STORM MANHOLE/ CATCH BASIN (CURB INLET CASTING) PROPOSED STORM SEWER CLENOUT PROPOSED RIPRAP PROPOSED FLARED END SECTION CO D NORTH C501GRADING PLAN - SITE B PROPOSED LIMITS OF DISTRUBANCE 8,571 SF AMENITY 2,840 SF RETAIL 3,222 SF RETAIL 832 SF AMENITY 4,000 SF RETAIL 556 SF COMMON / CIRCULATION 77 SF COMMON / CIRCULATION 152 SF BOH 452 SF MECH / ELEC 304 SF COMMON / CIRCULATION 21,298 SF PARKING 18,180 SF PARKING 374 SF STORAGE 143 SF COMMON / CIRCULATION 776 SF BOH 370 SF BOH 568 SF BOH 217 SF BOH CIRC PROPOSED BUILDING B FFE: 915.10 TO 920.00 P1 FFE: ±909.0 EXCELSIOR BL V D BLAKE ROAD S(CO. RD. NO. 3 )(CO. RO. NO. 20)(PUBLIC)(PUBLIC)DDDD D D D D D D D BMP 2A ± 400 LF - 60" CMP OR APPROVED EQUAL PIPE STORAGE: ± 10,106 CF PIPE IE: 910.18' T/PIPE: 915.18 2.00" DISCHARGE RATE: 1.24 CFS 100-YR HWL: 914.91' BMP 2C ± 100 LF - 48" CMP OR APPROVED EQUAL PIPE STORAGE: ± 4,574 CF PIPE IE: 912.34' 2.00" DISCHARGE RATE: 0.72 CFS 100-YR HWL: 916.04' BMP 2B 8' DIA. JELLYFISH TREATMENT MH OR APPROVED EQUAL 40" DEPTH CARTRIDGE RE: 915.81 IE (E) 910.18 IE (W): 910.06 TREATMENT CAPACITY: 1.30 CFS TRIBUTARY DRAINAGE AREA: 1.40 AC BMP 2D 6' DIA. JELLYFISH TREATMENT MH OR APPROVED EQUAL 40" DEPTH CARTRIDGE RE: 918.42 IE (E) 912.23 IE (W): 912.34 TREATMENT CAPACITY: 0.85 CFS TRIBUTARY DRAINAGE AREA: 0.80 AC OCS-02 STMH 48" DIA. RE:918.39 IE:912.34 W IE:912.34 S T/WEIR: 915.50 CONNECT TO EX. STMH-105 STMH 48" DIA. RE:915.71 IE:910.02 N IE:910.02 S OCS-01 STMH 48" DIA. RE:915.08 IE:910.18 E IE:910.18 S T/WEIR: 912.50 25 LF - 24" STORM PIPE @ 0.00% 10 LF - 12" STORM PIPE @ 0.00% 8 LF - 12" STORM PIPE @ 0.50% 8 LF - 24" STORM PIPE @ 0.00% 11 LF - 12" STORM PIPE @ 0.00% 7 LF - 12" STORM PIPE @ 0.50% BMP 1A ± 600 LF - 60" CMP OR APPROVED EQUAL PIPE STORAGE: ±11,500 CF PIPE IE: 909.50 2.00" DISCHARGE RATE: 2.79 CFS 100-YR HWL: 915.14 BMP 1B 8 X 8' JELLYFISH TREATMENT VAULT OR APPROVED EQUAL 54" DEPTH CARTRIDGE RE: 917.30 IE (W) 909.46 IE (E): 909.34 TREATMENT CAPACITY: 2.94 CFS TRIBUTARY DRAINAGE AREA: 1.95 AC 13 LF - 10" PVC @ 2.00% RD-3 ROOF DRAIN IE:914.45 W ST-3 CONNECT TO UNDERGROUND SW SYSTEM (INLET) IE:914.18 E RD-2 ROOF DRAIN IE:914.45 W ST-2 CONNECT TO UNDERGROUND SW SYSTEM (INLET) IE:914.18 E 13 LF - 10" PVC @ 2.00% RD-1 ROOF DRAIN IE:914.45 W 13 LF - 10" PVC @ 2.00% ST-1 CONNECT TO UNDERGROUND SW SYSTEM (INLET) IE:914.18 E ST-4 CONNECT TO UNDERGROUND SW SYSTEM (INLET) IE:915.34 N 14 LF - 10" PVC @ 2.00% RD-4 ROOF DRAIN IE:915.63 S 13 LF - 10" PVC @ 2.00% ST-5 CONNECT TO UNDERGROUND SW SYSTEM (INLET) IE:915.34 W RD-5 ROOF DRAIN IE:915.60 E D CONNECT TO EXISTING CURB INLET RE:2.95 IE:912.19 W 919 9199 1 9 9189 1 7 916 91 5 917 916 920918 919918918916918 917918 919 ST-7 UNDERGROUND STORM SYSTEM OUTLET IE:910.18 W ST-9 UNDERGROUND STORM SYSTEM OUTLET IE:912.34 E91891891791791 8 917917919 915 917918919919917918 Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed engineer under the laws of the State of Minnesota 7/17/2020160573033 BPG BLAKE ROAD STATION - SITE B BLAKE STATION SITE B Hopkins, MN 2/18/2022 No. Description Date 2022 KIMLEY-HORN AND ASSOCIATES, INC. 767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114 PHONE: 651-645-4197 WWW.KIMLEY-HORN.COM XX/XX/XXXX WDM LUA SUBMITTAL 12/14/2021 WILLIAM D. MATZEK 42661 NORTH GRADING PLAN NOTES 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY OF HOPKINS, SPECIFICATIONS AND BUILDING PERMIT REQUIREMENTS. 2. CONTRACTOR TO CALL GOPHER STATE CALL ONE @ 1-800-252-1166 AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATION/CONSTRUCTION FOR UTILITY LOCATIONS. 3. STORM SEWER PIPE SHALL BE AS FOLLOWS: RCP PER ASTM C-76 HDPE: 0" - 10" PER AASHTO M-252 HDPE: 12" OR GREATER PER ASTM F-2306 PVC SCH. 40 PER ASTM D-3034 STORM SEWER FITTINGS SHALL BE AS FOLLOWS: RCP PER ASTM C-76, JOINTS PER ASTM C-361, C-990, AND C-443 HDPE PER ASTM 3212 PVC PER ASTM D-3034, JOINTS PER ASTM D-3212 4. CONTRACTOR TO FIELD VERIFY THE LOCATIONS AND ELEVATIONS OR EXISTING UTILITIES AND TOPOGRAPHIC FEATURES PRIOR TO THE START OF SITE GRADING. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE PROJECT ENGINEER OF ANY DISCREPANCIES OR VARIATIONS. 5. SUBGRADE EXCAVATION SHALL BE BACKFILLED IMMEDIATELY AFTER EXCAVATION TO HELP OFFSET ANY STABILITY PROBLEMS DUE TO WATER SEEPAGE OR STEEP SLOPES. WHEN PLACING NEW SURFACE MATERIAL ADJACENT TO EXISTING PAVEMENT, THE EXCAVATION SHALL BE BACKFILLED PROMPTLY TO AVOID UNDERMINING OF EXISTING PAVEMENT. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL. 7. CONTRACTOR SHALL EXCAVATE DRAINAGE TRENCHES TO FOLLOW PROPOSED STORM SEWER ALIGNMENTS. 8. GRADES SHOWN ARE FINISHED GRADES. CONTRACTOR SHALL ROUGH GRADE TO SUBGRADE ELEVATION AND LEAVE STREET READY FOR SUBBASE. 9. ALL EXCESS MATERIAL, BITUMINOUS SURFACING, CONCRETE ITEMS, ANY ABANDONED UTILITY ITEMS, AND OTHER UNSTABLE MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF OFF THE CONSTRUCTION SITE. 10. REFER TO THE UTILITY PLAN FOR SANITARY SEWER MAIN, WATER MAIN SERVICE LAYOUT AND ELEVATIONS AND CASTING / STRUCTURE NOTATION. 11. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION OF PAVEMENTS AND CURB AND GUTTER WITH SMOOTH UNIFORM SLOPES TO PROVIDE POSITIVE DRAINAGE. 12. INSTALL A MINIMUM OF 4" CLASS 5 AGGREGATE BASE UNDER CURB AND GUTTER AND CONCRETE SIDEWALKS. 13. UPON COMPLETION OF EXCAVATION AND FILLING, CONTRACTOR SHALL RESTORE ALL STREETS AND DISTURBED AREAS ON SITE. ALL DISTURBED AREAS SHALL BE RE-VEGETATED WITH A MINIMUM OF 6" OF TOPSOIL. 14. ALL SPOT ELEVATIONS/CONTOURS ARE TO GUTTER / FLOW LINE UNLESS OTHERWISE NOTED. 15. GRADING FOR ALL SIDEWALKS AND ACCESSIBLE ROUTES INCLUDING CROSSING DRIVEWAYS SHALL CONFORM TO CURRENT ADA STATE/NATIONAL STANDARDS. IN NO CASE SHALL ACCESSIBLE RAMP SLOPES EXCEED 1 VERTICAL TO 12 HORIZONTAL. IN NO CASE SHALL SIDEWALK CROSS SLOPES EXCEED 2% . IN NO CASE SHALL LONGITUDINAL SIDEWALK SLOPES EXCEED 5%. IN NO CASE SHALL ACCESSIBLE PARKING STALLS OR AISLES EXCEED 2% (1.5% TARGET) IN ALL DIRECTIONS. SIDEWALK ACCESS TO EXTERNAL BUILDING DOORS AND GATES SHALL BE ADA COMPLIANT. CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF ADA CRITERIA CANNOT BE MET IN ANY LOCATION PRIOR TO PAVING. NO CONTRACTOR CHANGE ORDERS WILL BE ACCEPTED FOR A.D.A COMPLIANCE ISSUES. 16. MAINTAIN A MINIMUM OF 0.5% GUTTER SLOPE TOWARDS LOW POINTS. 17. CONTRACTOR TO PROVIDE 3" INSULATION BY 5' WIDE CENTERED ON STORM PIPE IF LESS THAN 4' OF COVER IN PAVEMENT AREAS AND LESS THAN 3' OF COVER IN LANDSCAPE AREAS. 18. ROOF DRAIN INVERT CONNECTIONS AT THE BUILDING SHALL BE AT ELEVATION <XXX.XX> OR LOWER UNLESS NOTED OTHERWISE. REFERENCE MEP PLANS FOR ROOF DRAIN CONNECTION. 19. ALL STORM SEWER CONNECTIONS SHALL BE GASKETED AND WATER TIGHT INCLUDING MANHOLE CONNECTIONS. 20. ALL STORM SEWER PIPE SHALL BE AIR TESTED IN ACCORDANCE WITH THE CURRENT PLUMBING CODE. 21. MAINTAIN A MINIMUM OF 1.25% SLOPE IN BITUMINOUS PAVEMENT AREAS, 0.5% SLOPE IN CONCRETE PAVEMENT AREAS. 22. CONTRACTOR SHALL REVIEW PAVEMENT GRADIENT AND CONSTRUCT "INFALL CURB" WHERE PAVEMENT DRAINS TOWARD GUTTER, AND "OUTFALL" CURB WHERE PAVEMENT DRAINS AWAY FROM GUTTER. PROPOSED STORM MANHOLE (SOLID CASTING) PROPOSED STORM SEWER PROPOSED STORM MANHOLE (ROUND INLET CASTING) PROPOSED STORM SEWER PROPERTY LINE LEGEND PROPOSED SANITARY SEWER PROPOSED WATERMAIN CO PROPOSED STORM MANHOLE/ CATCH BASIN (CURB INLET CASTING) PROPOSED STORM SEWER CLENOUT PROPOSED RIPRAP PROPOSED FLARED END SECTION D PROPOSED UNDERGROUND STORMWATER PIPE DETENTION C503 STORM SEWER PLAN - SITE B STORMWATER SUMMARY - BUILDING B PARCEL BLAKE & EXCELSIOR - SITE B PROPERTY AREA (SITE B)94,332 SF (2.17 AC) PROPOSED SITE IMPERVIOUS AREA 86,096 SF (1.98 AC) TRIBUTARY AREA TO BMP 2A/B 61,131 SF (1.40 AC) TRIBUTARY AREA TO BMP 2C/D 23,557 SF (0.54 AC) DISTURBED AREA 95,876 SF (2.20 AC) RATE ATTENUATION SUMMARY 1-YEAR (CFS) 10-YEAR (CFS) 100-YEAR (CFS) BLAKE ROAD S. EXISTING 3.63 6.60 11.77 PROPOSED 1.23 4.40 7.97 EXCELSIOR BOULEVARD EXISTING 3.35 5.90 10.37 PROPOSED 1.22 5.61 7.88 TOTAL EXISTING 6.98 12.49 22.15 PROPOSED 2.35 9.27 15.08 RUNOFF VOLUME SUMMARY REQUIRED TREATMENT VOLUME: MCWD REQUIRES A VOLUME ABSTRACTION OF 1" OVER THE IMPERVIOUS AREA (7,175 CF) OR TREATMENT OF THE FLOW RATE RESULTING FROM THE 2" EVENT OVER THE IMPERVIOUS AREA FOR FILTRATION PRACTICES. 14,350 CF PROVIDED TREATMENT VOLUME: TO DEMONSTRATE THE UNDERGROUND DETENTION AND TREATMENT VAULT HAVE SUFFICIENT CAPACITY, THE 2" EVENT IS MODELED WITH A 2.55" RAINFALL DEPTH THAT RESULTS IN THE PROVIDED TREATMENT VOLUME. 14,680 CF WATER QUALITY SUMMARY REQUIRED TSS REMOVAL 70% SITE CAPTURE 88.33% BMP 2B/2D TSS REMOVAL RATE 80% BMP 2B DISCHARGE RATE/TREATMENT CAPACITY 1.24 CFS/1.30 CFS BMP 2D DISCHARGE RATE/TREATMENT CAPACITY 0.72 CFS/0.85 CFS PROVIDED TSS REMOVAL 70.66% (88.33% SITE CAPTURE * 80% REMOVAL) PROPOSED FINGER DRAIN - INSTALL AROUND CATCH BASINS, 4 DRAINS, SPACED AT 90°, EXTENDING 10' FROM CATCH BASIN EXCELSIOR BL V D BLAKE ROAD S(CO. RD. NO. 3 )(CO. RO. NO. 20)(PUBLIC)(PUBLIC)B DDD 8" X 6" 8" 8" X 8" D D D D D 10.0'11.0'8,571 SF AMENITY 2,840 SF RETAIL 3,222 SF RETAIL 832 SF AMENITY 4,000 SF RETAIL 556 SF COMMON / CIRCULATION 77 SF COMMON / CIRCULATION 152 SF BOH 452 SF MECH / ELEC 304 SF COMMON / CIRCULATION 21,298 SF PARKING 18,180 SF PARKING 374 SF STORAGE 143 SF COMMON / CIRCULATION 776 SF BOH 370 SF BOH 568 SF BOH 217 SF BOH CIRC PROPOSED BUILDING B FFE: 915.10 TO 920.00 P1 FFE: ±909.0 EXISTING WATER / SANITARY EASEMENT EXISTING OVERHEAD POWER SERVICE, MAINTAIN SERVICE TO ADJACENT PROPERTIES EXISTING POWER POLE TO REMAIN PROPOSED 8" WATER MAIN C G B E E I F G I F G R150' PROPOSED HYDRANT COVERAGE F J A I I PROPOSED UNDERGROUND GAS LINE, COORD. W / UTILITY PROPOSED UNDERGROUND TELEPHONE LINE, COORD. W / UTILITY EXISTING POWER POLES TO REMAIN CORE DRILL CONNECT TO EXISTING SSWR MH, CONTRACTOR TO FIELD VERIFY INVERT ELEVATIONS AND LOCATIONS REMOVE EXISTING SANITARY SEWER STUB, CONSTRUCT CLEANOUT STRUCTURE AND CONNECT TO EXISTING SERVICE LINE EXISTING LIGHT POLE TO REMAIN EXISTING LIGHT POLE TO BE SALVAGED AND RELOCATED C H H COCOSS-9 48" SSWR MH IE:904.76 SW IE:904.60 E IE:904.60 N IE:904.60 W 102 LF - 8" PVC @ 2.00% SS-8 CLEANOUT IE:906.80 S IE:906.80 NE 5 LF - 8" PVC @ 2.00%SS-7 STUB IE:906.90 N 6 LF - 8" PVC @ 2.00% SS-1 STUB IE:907.86 W SS-2 CLEANOUT IE:907.75 E IE:907.75 SW A A CONNECT TO EXISTING WATER SERVICE LINE Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed engineer under the laws of the State of Minnesota 7/17/2020160573033 BPG BLAKE ROAD STATION - SITE B BLAKE STATION SITE B Hopkins, MN 2/18/2022 No. Description Date 2022 KIMLEY-HORN AND ASSOCIATES, INC. 767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114 PHONE: 651-645-4197 WWW.KIMLEY-HORN.COM XX/XX/XXXX WDM LUA SUBMITTAL 12/14/2021 WILLIAM D. MATZEK 42661 CO SANITARY CLEANOUTCO EXISTING PROPOSED UTILITY PLAN NOTES 1. ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF PROPOSED UTILITIES. 2. SANITARY SEWER PIPE SHALL BE AS FOLLOWS: 8" PVC SDR35 PER ASTM D-3034, FOR PIPES LESS THAN 12' DEEP 8" PVC SDR26 PER ASTM D-3034, FOR PIPES MORE THAN 12' DEEP 6" PVC SCHEDULE 40 PER ASTM D-3034 DUCTILE IRON PIPE PER AWWA C150 3. WATER LINES SHALL BE AS FOLLOWS: 6" AND LARGER, PVC C-900 PER ASTM D 2241 CLASS 200 UNDER COUNTY ROADS, OTHERWISE CLASS 150 4" AND LARGER DUCTILE IRON PIPE PER AWWA C150 SMALLER THAN 3" PIPING SHALL BE COPPER TUBE TYPE "K" PER ANSI 816.22 WATER LINES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MOST RECENT EDITION OF CEAM SPECIFICATIONS 4. MINIMUM TRENCH WIDTH SHALL BE 2 FEET. 5. ALL WATER JOINTS ARE TO BE MECHANICAL JOINTS WITH RESTRAINTS SUCH AS THRUST BLOCKING, WITH STAINLESS STEEL OR COBALT BLUE BOLTS, OR AS INDICATED IN THE CITY SPECIFICATIONS AND PROJECT DOCUMENTS. 6. ALL UTILITIES SHOULD BE KEPT TEN (10') APART (PARALLEL) OR WHEN CROSSING 18" VERTICAL CLEARANCE (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE OR STRUCTURE). 7. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 7'-5" COVER ON ALL WATERLINES. 8.IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, STORM LINES AND GAS LINES, OR ANY OBSTRUCTION (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE SCH. 40 OR C900 WITH MECHANICAL JOINTS AT LEAST 10 FEET ON EITHER SIDE OF THE CENTER LINE OF THE CROSSING. THE WATER LINE SHALL HAVE MECHANICAL JOINTS WITH APPROPRIATE FASTENERS AS REQUIRED TO PROVIDE A MINIMUM OF 18" VERTICAL SEPARATION. MEETING REQUIREMENTS OF ANSI A21.10 OR ANSI 21.11 (AWWA C-151) (CLASS 50). 9. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING. 10. TOPS OF MANHOLES SHALL BE RAISED AS NECESSARY TO BE FLUSH WITH PROPOSED PAVEMENT ELEVATIONS, AND TO BE ONE FOOT ABOVE FINISHED GROUND ELEVATIONS, IN GREEN AREAS, WITH WATERTIGHT LIDS. 11. ALL CONCRETE FOR ENCASEMENTS SHALL HAVE A MINIMUM 28 DAY COMPRESSION STRENGTH AT 3000 P.S.I. 12. EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW LINES. 13. REFER TO INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL UTILITIES. 14. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE CITY OF HOPKINS AND/OR STATE OF MINNESOTA WITH REGARDS TO MATERIALS AND INSTALLATION OF THE WATER AND SEWER LINES. 15. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 16. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES. 17. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND SPECIFICATIONS. 18. CONTRACTOR SHALL REFERENCE ARCH / MEP PLANS FOR SITE LIGHTING AND ELECTRICAL PLAN. 19. BACKFLOW DEVICES (DDCV AND PRZ ASSEMBLIES) AND METERS ARE LOCATED IN THE INTERIOR OF THE BUILDING. REF. ARCH / MEP PLANS. 20. ALL ONSITE WATERMAINS AND SANITARY SEWERS SHALL BE PRIVATELY OWNED AND MAINTAINED. 21. ALL WATERMAIN STUBOUTS SHALL BE MECHANICALLY RESTRAINED WITH REACTION BLOCKING. 22. THE WATER DISTRIBUTION SYSTEM SHALL BE DISINFECTED IN ACCORDANCE WITH MN PLUMBING CODE RULES PER SECTION 609.9.A 23. THE PLUMBING SYSTEM SHALL BE TESTED IN ACCORDANCE WITH MN PLUMBING CODE RULES PER SECTIONS 609.4 AND 712.0. THIS SHALL INCLUDE THE STORM SEWER LOCATED WITHIN 10 FEET OF THE BUILDING AND WITHIN 10 FEET OF THE BURIED WATER SUPPLY. 24. ALL PORTIONS OF THE STORM SEWER SYSTEM LOCATED WITHIN 10 FEET OF THE BUILDING OR WATER SERVICE LINE MUST BE TESTED IN ACCORDANCE WITH MINNESOTA RULES, CHAPTER 474, SECTION 1109. 25. ALL STORM PIPE ENTERING STRUCTURES SHALL BE WATERTIGHT OR BE OF FLEXIBLE COMPRESSION JOINTS LOCATED BETWEEN 12 ANDN 36 INCHES FROM MANHOLE. JOINT CONNECTIONS SHALL BE FLEXIBLE WATER STOPS, RESILIENT CONNECTORS, OR OTHER FLEXIBLE SYSTEMS APPROVED BY THE ENGINEER TO MAKE WATERTIGHT CONNECTION TO MANHOLES AND OTHER STRUCTURES UNLESS OTHERWISE STATED BY CITY AND STATE DESIGN STANDARDS AND SPECIFICATIONS. CEMENT MORTAR JOINTS ARE NOT APPROVED NORTH SANITARY SEWER KEYNOTE LEGEND SANITARY SEWER SERVICE. CONNECT TO BUILDING PLUMBING COORDINATE W/ MEP PLANS ADJUST EXISTING CASTING TO NEW RIM ELEVATION CONSTRUCT MANHOLE OVER EXISTING SANITARY SEWER. CONNECT TO EXISTING SERVICE PIPE. FIELD VERIFY LOCATION AND ELEVATION. CORE DRILL AND CONNECT TO EXISTING STRUCTURE. FIELD VERIFY LOCATION AND ELEVATION A B C D SANITARY SEWER MANHOLE STORM SEWER SANITARY SEWER WATERMAIN GATE VALVE HYDRANT TEE REDUCER UNDERGROUND ELECTRIC TELEPHONE GAS MAIN STORM SEWER LEGEND PROPOSED UNDERGROUND STORMWATER PIPE DETENTION C601UTILITY PLAN - SITE B WATERMAIN KEYNOTE LEGEND PROPOSED 8" FIRE WATER SERVICE, PROVIDE BACKFLOW PREVENTER INSIDE BUILDING CONNECT TO EXISTING WATER STUB CAP EXISTING TEE TO THE EAST AFTER REMOVING EXISTING WATER SERVICE LINE CONNECT TO EXISTING WATER LINE TO MAINTAIN SERVICE EXISTING HYDRANT (SITE A) PROPOSED FIRE HYDRANT AND GATE VALVE ASSEMBLY, PROVIDE 6" LEAD TEE 45-DEGREE BEND GATE VALVE PROPOSED 6" DOMESTIC WATER SERVICE A B C D E F G H I J ELECTRIC XCEL ENERGY 5309 W. 70TH STREET EDINA, MN 55439 TELEPHONE: (952) 380-2637 CONTACT: JACOB MOCK COMMUNICATIONS LUMEN 301 65TH STREET W RICHFIELD, MN 55423 TELEPHONE: (612) 431-3529 CONTACT: LUCAS PELUSO GAS CENTERPOINT ENERGY TELEPHONE: (612) 321-5505 CONTACT: ANTHONY LAFFRADO COMMUNICATIONS COMCAST TELEPHONE: (612) 369-1284 CONTACT: RICHARD MISKE FULL DEPTH SAWCUT PROJECT NUMBERDRAWN BY CHECKED BY20-172BD JSORIGINAL ISSUE:REVISIONS:No.Description DateKEY PLAN--/--/----26970Jesse SymynkywiczSignatureTyped or Printed NameLicense # DatePROJECT NUMBERDRAWN BY CHECKED BYORIGINAL ISSUE:REVISIONS:KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, orreport was prepared by me or under my directsupervision and that I am a duly licensedlandscape architect under the laws of theState of Minnesota310 South 4th Avenue, Suite 7050Minneapolis, MN 55415p: 612.332.752220-172BLAKE ROAD STATIONBLAKE STATIONBLDG BHOPKINS, MN 55343LUA SUBMITTAL02/18/2022No. Description DateOVERALL SITE PLANL100BIKERACKSDOUBLE-SIDEDBENCHBUS STOP PLAZACURBED PLANTING BEDS(10' - 13' WIDTH / 30"OFFSET FROM CURB)STREET LIGHTINGCONCRETE WALKWAY(10' WIDTH)MONUMENT SIGNBENCHBIKE RACKSRETAIL PATIOCITY STANDARDPAVING / STREETSCAPEBIKE RACKBIKE RACKBIKE RACKBIKE RACKSGOOD WILL SIGNBENCHDOGRELIEFAREAPLAY AREABENCHGABION WALL / BENCHESSTEEL PLANTERSWOOD DECKCRUSHEDSTONESEATINGAREANORTH0SCALE:1" = 30'30 6090STREET LIGHTINGRELOCATED CABINETAND ANTENNACURBED PLANTING BEDS(7' - 11' WIDTH / 30"OFFSET FROM CURB)CONCRETE WALKWAY(9' WIDTH)6' HT. SCREEN FENCEFOUNDATIONPLANTINGSPROPERTY LINEPROPERTY LINEBOULEVARDPLANTINGSFOUNDATIONPLANTINGSBIKERACKSBENCH CONCRETE PAVINGCONCRETE UNIT PAVERSCRUSHED STONEWOOD DECKPLAY SURFACINGPLANTING TYPE 1PLANTING TYPE 2PLANTING TYPE 3OVERALL SITE PLAN LEGENDAREAWELL Xref .\3 Xrefs\Arch\Blake Road Station Site B.dwg 6'-0"SF-01SN-029'-6"1'-4 1/2"SF-02P-0510'-0"P-05P-05P-01P-01P-01P-01P-01EXISTING 'EXCELSIOR'LIGHT POLE(DOES NOT MOVE FROMEXISTING LOCATION)EXISTING 'EXCELSIOR'LIGHT POLE(DOES NOT MOVE FROMEXISTING LOCATION)PLANTINGAREAPLANTINGAREAPLANTINGAREAPLANTINGAREAPLANTINGAREAPLANTINGAREABUS STOPSN-01PROPOSEDMONUMENTSIGNPROPOSEDGOODWILLSIGNPLANTINGAREAAREAWELLSF-02P-05P-05CB-01CB-01CB-01CB-01LT-01'BLAKE ROAD'STANDARDLIGHT POLEP-05'BLAKE ROAD'STANDARDLIGHT POLELT-01LT-0110'-0"FE-0210'-0"11'-0"6'-0"6'-0"PLANTINGAREAP-01P-015'-0"TCAREAWELL5'-0"FE-0118'-0"TCP-01P-01P-01SF-01WL-01PE-01PE-03PE-02P-04AM-01WL-01LT-0212' LIGHTS(SIMILAR TOPHASE 'A')P-01P-01P-01P-01P-01P-03DOG RELIEF AREACRUSHED STONELT-02ED-101P-03SF-07SF-04LT-03WL-02SF-05SF-05SF-05SF-07LT-03SF-03WL-01FE-026'-0"6'-0"6'-0"E X C E L S I O R A V E N U E B L A K E R O A D 14' LIGHTCOLUMNSF-06SF-06SF-06SF-06SF-06SF-06PLANTING AREA PLANTING AREA PLANTING AREA PLANTINGAREAPLANTINGAREAPLANTINGAREAPLANTINGAREAPLANTINGAREAPLANTINGAREAAMENITYSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYWOOD DECK/MINI STAGE126 SF TBDCURBSYMBOL DESCRIPTIONQTYMANUFACTURERPRODUCT/MODELCOLOR/FINISHCONCRETE PLANTER CURB621 LF CUSTOMCONCRETE CURBINGSTANDARD CONCRETEEDGINGSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYMANUFACTURERPRODUCT/MODELSTEEL EDGING46 LF3/16" GALVANIZED STEELRYERSON3/16" GALVANIZED STEELFENCE & GUARDRAILSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYSCREEN FENCE244 LF 6` HEIGHT WOODEN FENCEUTILITY SCREEN FENCE235 LF MATCH PHASE 1 DESIGNLIGHTINGSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYEXCELSIOR STREET LIGHT3PEDESTRIAN LIGHT312` HEIGHTPEDESTRIAN COLUMN LIGHT614` HEIGHTPAVINGSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYCONCRETE PAVING14,738 SF4" CONCRETE PAVEMENT OVER 6"COMPACTED AGGREGATE BASE, COMPACTEDSUBGRADECONCRETE PAVING - VEHICULAR703 SF6" REINFORCED VEHICULAR RATEDCONCRETE PAVEMENT, OVER COMPACTEDAGGREGATE BASE, COMPACTED SUBGRADESTABILIZED CRUSHED STONE662 SF3" DEPTH 3/8" DECOMPOSED GRANITE,STABILIZED, OVER COMPACTED AGGREGATEBASE OVER COMPACTED SUBGRADEPLAY AREA SURFACE305 SFENGINEERED WOOD FIBER, DEPTH PER ASTMSTND. WITH SUBSURFACE DRAINGE SYSTEMCONCRETE UNIT PAVER2,690 SFTBDPLAY EQUIPMENTSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYMANUFACTURERPRODUCT/MODELPLAY BOULDER5BALANCE BEAM110′ 2″ X 6″ X 1′ 3″KOMPANNRO887-0601STILTS14′ 2″ X 8′ 1″ X 3′ 7″KOMPANNRO806-0601SITE FURNITURESYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYMANUFACTURERPRODUCT/MODELLINEAR BENCH - 8`22` X 8` LINEAR BENCHANOVAINF24L8TLINEAR BENCH - 10`22` X 10` LINEAR BENCHANOVAINF24L10TCAST CONCRETE BENCH4REINFORCED CAST STONE BENCH, 75" X 67" X17"LANDSCAPE FORMSFLOR-SMCURVED BENCH12` CURVED BENCH 16` RADIUSANOVAINF24C1690TGABION BENCH42` X 6` GABION BENCH, FILL W/ DRESSOR TRAPROCKANOVACE1872TBIKE RACK10FORMS + SURFACESTRIO BIKE RACKMOVABLE CHAIR11TBDMOVABLE TABLE6TBDSIGNAGESYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYMONUMENT SIGN1TBDGOOD WILL SIGN1RELOCATED GOOD WILL SIGNWALLSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYSTEEL PLANTER WALL120 LF16" HEIGHT WEATHERING STEEL PLANTERWALL WITH BENT TOPWALLSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYAM-01CB-01ED-101FE-01FE-02LT-01LT-02LT-03P-01P-02P-03P-04P-05PE-01PE-02PE-03SF-01SF-02SF-03SF-04SF-05SF-06SF-07SF-08SN-01SN-02WL-01REFERENCE NOTES SCHEDULEAMENITYSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYWOOD DECK/MINI STAGE126 SF TBDCURBSYMBOL DESCRIPTIONQTYMANUFACTURERPRODUCT/MODELCOLOR/FINISHCONCRETE PLANTER CURB621 LF CUSTOMCONCRETE CURBINGSTANDARD CONCRETEEDGINGSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYMANUFACTURERPRODUCT/MODELSTEEL EDGING46 LF3/16" GALVANIZED STEELRYERSON3/16" GALVANIZED STEELFENCE & GUARDRAILSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYSCREEN FENCE244 LF 6` HEIGHT WOODEN FENCEUTILITY SCREEN FENCE235 LF MATCH PHASE 1 DESIGNLIGHTINGSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYEXCELSIOR STREET LIGHT3PEDESTRIAN LIGHT312` HEIGHTPEDESTRIAN COLUMN LIGHT614` HEIGHTPAVINGSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYCONCRETE PAVING14,738 SF4" CONCRETE PAVEMENT OVER 6"COMPACTED AGGREGATE BASE, COMPACTEDSUBGRADECONCRETE PAVING - VEHICULAR703 SF6" REINFORCED VEHICULAR RATEDCONCRETE PAVEMENT, OVER COMPACTEDAGGREGATE BASE, COMPACTED SUBGRADESTABILIZED CRUSHED STONE662 SF3" DEPTH 3/8" DECOMPOSED GRANITE,STABILIZED, OVER COMPACTED AGGREGATEBASE OVER COMPACTED SUBGRADEPLAY AREA SURFACE305 SFENGINEERED WOOD FIBER, DEPTH PER ASTMSTND. WITH SUBSURFACE DRAINGE SYSTEMCONCRETE UNIT PAVER2,690 SFTBDPLAY EQUIPMENTSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYMANUFACTURERPRODUCT/MODELPLAY BOULDER5BALANCE BEAM110′ 2″ X 6″ X 1′ 3″KOMPANNRO887-0601STILTS14′ 2″ X 8′ 1″ X 3′ 7″KOMPANNRO806-0601SITE FURNITURESYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYMANUFACTURERPRODUCT/MODELLINEAR BENCH - 8`22` X 8` LINEAR BENCHANOVAINF24L8TLINEAR BENCH - 10`22` X 10` LINEAR BENCHANOVAINF24L10TCAST CONCRETE BENCH4REINFORCED CAST STONE BENCH, 75" X 67" X17"LANDSCAPE FORMSFLOR-SMCURVED BENCH12` CURVED BENCH 16` RADIUSANOVAINF24C1690TGABION BENCH42` X 6` GABION BENCH, FILL W/ DRESSOR TRAPROCKANOVACE1872TBIKE RACK10FORMS + SURFACESTRIO BIKE RACKMOVABLE CHAIR11TBDMOVABLE TABLE6TBDSIGNAGESYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYMONUMENT SIGN1TBDGOOD WILL SIGN1RELOCATED GOOD WILL SIGNWALLSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYSTEEL PLANTER WALL120 LF16" HEIGHT WEATHERING STEEL PLANTERWALL WITH BENT TOPWALLSYMBOL DESCRIPTIONQTYMATERIAL PROFILE/ASSEMBLYREFERENCEBNOTESBSCHEDULEAM-01CB-01ED-101FE-01FE-02NORTH0SCALE:1"=16'16' 32'48'PROJECT NUMBERDRAWN BY CHECKED BY20-172BD JSORIGINAL ISSUE:REVISIONS:No.Description DateKEY PLAN--/--/----26970Jesse SymynkywiczSignatureTyped or Printed NameLicense # DatePROJECT NUMBERDRAWN BY CHECKED BYORIGINAL ISSUE:REVISIONS:KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, orreport was prepared by me or under my directsupervision and that I am a duly licensedlandscape architect under the laws of theState of Minnesota310 South 4th Avenue, Suite 7050Minneapolis, MN 55415p: 612.332.752220-172BLAKE ROAD STATIONBLAKE STATIONBLDG BHOPKINS, MN 55343LUA SUBMITTAL02/18/2022No. Description DateSITE PLAN - BUILDING BL111 EXCELSIOR BLVDBLAKE ROAD S15'-5 1/2"11'-10"6'-0"39 - CA-A7 - GL-I26 - CA-A59 - CA-A64 - CA-A54 - SO-S19 - SP-H21 - AR-A6 - EC-W22 - SS-P26 - NE-F22 - SS-P6 - EC-W26 - NE-F22 - SS-P7 - SP-H10 - AR-A39 - CA-A2 - GL-T10 - PE-A23 - PA-H14 - AR-A11 - SP-H7 - SO-S16 - AR-M11 - LI-K29 - SA-N14 - IR-S24 - SB24 - SB24 - SB24 - SB24 - SB22 - HB21 - HB20 - HB18 - HB21 - HB18 - HB21 - HB15 - HB4 - QB15 - SB15 - SB21 - SB5 - RI-A5 - TN4 - TH-H3 - TN6 - RI-A1 - TH-H41 - TN18 - HY-P2 - AG3 - TH-H36 - CA-A21 - AR-M2 - TH-H10 - HY-P10 - TN3 - AG1 - AG8 - QU-L22 - PH-O22 - AA43 - TH-H28 - PE-A46 - PA-H5 - BF18 - PE-A29 - PA-H35 - PE-A8 - BF61 - PA-H13 - PE-A6 - SO-S5 - AC-M41 - SO-S8 - TI-S7 - CA-V2 - BA-A10 - CA-V12 - TI-S4 - BA-A8 - TI-S9 - CA-V4 - BA-A81 - SB22 - CA-A11 - EP311 - SA-N9 - NE-F13 - AT-S27 - SB14 - HB38 - SP-BDECIDUOUS TREES CODE QTY BOTANICAL / COMMON NAMEAC-M 5 ACER MIYABEI `MORTON` TM / STATE STREET MIYABEI MAPLEBF 13 BETULA PLATYPHYLLA 'FARGO' TM / DAKOTA PINNACLE ASIAN WHITE BIRCHGL-T 2 GLEDITSIA TRIACANTHOS DRAVES / HONEY LOCUST STREET KEEPERGL-I 7 GLEDITSIA TRIACANTHOS INERMIS `SKYCOLE` TM / SKYLINE THORNLESS HONEY LOCUSTQB4QUERCUS BICOLOR / SWAMP WHITE OAKQU-L8QUERCUS X WAREI `LONG` TM / REGAL PRINCE OAKORNAMENTAL TREES CODEQTYBOTANICAL / COMMON NAMEAG 6 AMELANCHIER X GRANDIFLORA `AUTUMN BRILLIANCE` / `AUTUMN BRILLIANCE` SERVICEBERRYSHRUBSCODEQTYBOTANICAL / COMMON NAMEAA422ARONIA MELANOCARPA `AUTUMN MAGIC` / AUTUMN MAGIC BLACK CHOKEBERRYAR-M 37 ARONIA MELANOCARPA `UCONNAM165` / LOW SCAPE MOUND CHOKEBERRYHY-P 28 HYDRANGEA PANICULATA 'JANE' TM / LITTLE LIME PANICLE HYDRANGEAPH-O22PHYSOCARPUS OPULIFOLIUS `DART`S GOLD` / DART`S GOLD NINEBARKRI-A11RIBES ALPINUM / ALPINE CURRANTSO-S 108 SORBARIA SORBIFOLIA `SEM` / SEM ASH LEAF SPIREASP-B 38 SPIRAEA BETULIFOLIA 'TOR GOLD' TM / GLOW GIRL BIRCHLEAF SPIREATN 59 TAXUS X MEDIA `TAUNTON` / TAUNTON YEWEVERGREEN SHRUBSCODEQTYBOTANICAL / COMMON NAMETH-H 13THUJA OCCIDENTALIS `HOLMSTRUP` / HOLMSTRUP ARBORVITAEGRASSESCODEQTYBOTANICAL / COMMON NAMECA-A285CALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER` / FEATHER REED GRASSCA-V26CAREX VULPINOIDEA / FOX SEDGEPA-H159PANICUM VIRGATUM 'HEAVY METAL' / HEAVY METAL SWITCH GRASSSS-P66SCHIZACHYRIUM SCOPARIUM 'PRAIRIE BLUES' / PRAIRIE BLUES LITTLE BLUESTEMSB279SCHIZACHYRIUM SCOPARIUM `BLUE HEAVEN` / BLUE HEAVEN LITTLE BLUESTEMSP-H37SPOROBOLUS HETEROLEPIS / PRAIRIE DROPSEEDPERENNIALSCODEQTYBOTANICAL / COMMON NAMEAT-S13ALLIUM TANGUTICUM 'SUMMER BEAUTY' / SUMMER BEAUTY GLOBE LILYAR-A45ARUNCUS AETHUSIFOLIUS / DWARF GOATSBEARDBA-A10BAPTISIA AUSTRALIS / BLUE WILD INDIGOEP311 ECHINACEA PALLIDA / PALE PURPLE CONEFLOWEREC-W 12 ECHINACEA PURPUREA 'WHITE SWAN' / WHITE SWAN CONEFLOWERHB170HEMEROCALLIS X 'BAJA' / BAJA DAYLILYIR-S 14 IRIS SIBIRICA 'CAESAR'S BROTHER' / CAESAR'S BROTHER SIBERIAN IRISLI-K 11 LIATRIS SPICATA 'KOBOLD' / KOBOLD BLAZING STARNE-F61NEPETA X FAASSENII 'WALKER'S LOW' / WALKER'S LOW CATMINTPE-A104PEROVSKIA ATRIPLICIFOLIA 'BLUE JEAN BABY' / BLUE JEAN BABY RUSSIAN SAGESA-N40SALVIA NEMOROSA 'CARADONNA' / CARDONNA MEADOW SAGETI-S28TIARELLA X 'SUGAR AND SPICE' / SUGAR AND SPICE FOAMFLOWERPLANT SCHEDULE LANDSCAPENORTH0SCALE:1"=16'16' 32'48'PROJECT NUMBERDRAWN BY CHECKED BY20-172BD JSORIGINAL ISSUE:REVISIONS:No.Description DateKEY PLAN--/--/----26970Jesse SymynkywiczSignatureTyped or Printed NameLicense # DatePROJECT NUMBERDRAWN BY CHECKED BYORIGINAL ISSUE:REVISIONS:KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, orreport was prepared by me or under my directsupervision and that I am a duly licensedlandscape architect under the laws of theState of Minnesota310 South 4th Avenue, Suite 7050Minneapolis, MN 55415p: 612.332.752220-172BLAKE ROAD STATIONBLAKE STATIONBLDG BHOPKINS, MN 55343LUA SUBMITTAL02/18/2022No. Description DateLANDSCAPE PLAN -BUILDING BL140 PROJECT NUMBERDRAWN BY CHECKED BY20-172BD JSORIGINAL ISSUE:REVISIONS:No.Description DateKEY PLAN--/--/----26970Jesse SymynkywiczSignatureTyped or Printed NameLicense # DatePROJECT NUMBERDRAWN BY CHECKED BYORIGINAL ISSUE:REVISIONS:KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, orreport was prepared by me or under my directsupervision and that I am a duly licensedlandscape architect under the laws of theState of Minnesota310 South 4th Avenue, Suite 7050Minneapolis, MN 55415p: 612.332.752220-172BLAKE ROAD STATIONBLAKE STATIONBLDG BHOPKINS, MN 55343LUA SUBMITTAL02/18/2022No. Description DateLANDSCAPE SECTIONSL40013'-0"10'-0"5'-11"SIDEWALKRAISEDPLANTERBOULEVARDEXCELSIOR BOULEVARDSECTION - STREETSCAPE @ EXCELSIOR1" 1'-0"3'-0"2P-21261-036'-0"10'-0" - 11'-0"13'-2"SIDEWALKPATIOBOULEVARDBLAKE ROADSECTION - STREETSCAPE @ BLAKE ROAD1" 1'-0"1P-21261-0 PROJECT NUMBERDRAWN BY CHECKED BY20-172BD JSORIGINAL ISSUE:REVISIONS:No.Description DateKEY PLAN--/--/----26970Jesse SymynkywiczSignatureTyped or Printed NameLicense # DatePROJECT NUMBERDRAWN BY CHECKED BYORIGINAL ISSUE:REVISIONS:KEY PLANNOT FORCONSTRUCTIONI hereby certify that this plan, specification, orreport was prepared by me or under my directsupervision and that I am a duly licensedlandscape architect under the laws of theState of Minnesota310 South 4th Avenue, Suite 7050Minneapolis, MN 55415p: 612.332.752220-172BLAKE ROAD STATIONBLAKE STATIONBLDG BHOPKINS, MN 55343LUA SUBMITTAL02/18/2022No. Description DateLANDSCAPE DETAILSL500SITE BENCH - INGROUND MOUNT1" = 1'-0"&21&5(7( 6,'(:$/.6(( &,9,/&20P$&7(' $**5(*$7( %$6(.6(( &,9,/P5(P$5(' 68%*5$'(/$1'6&$P( )2506 - %$1&$/ %(1&+,167$// P(5 0$18)$&785(5'6 ',5(&7,21P-21.261-7513" 7+.. 316" 0,186 75$P52&.6" 7+.. &/$66 5 %$6(-&20P$&7 72 8P52&725 '(16,7<&20P$&7(' 68%%$6(CRUSHED STONE PAVING1" = 1'-0"2P-21.261-67&21&5(7( 6,'(:$/.6(( &,9,/&20P$&7(' $**5(*$7( %$6(6(( &,9,/P5(P$5(' 68%*5$'()2506  685)$&(6 75,2%,.( 5$&. - "6/$7("(0%(''(' 02817 P(5 0$18)$&785(5'6',5(&7,21BIKE RACK, SURFACE MOUNT1" = 1'-0"2'-10"P-21.261-68P-21.261-6831136" 5$',86',* P/$17,1* P,7 4" 72 6" '((P(5 7+$1 5227 %$//81',6785%(' 68%*5$'(NOTE:&2175$&725 6+$// %( 5(6P216,%/( )250$,17$,1,1* 75((6 ,1 $ P/80% P26,7,217+528*+287 7+( :$55$17< P(5,2'. :5$P75(( 7581.6 21/< 8P21 $PP529$/ %</$1'6&$P( $5&+,7(&7. 6(( 6P(&,),&$7,216(&7,21 5(/$7(' 72 P/$176 $1' 62,/P5(P$5$7,21.($&+ 75(( 6+$// %( P/$17(' 68&+ 7+$7 7+(5227 )/$5( ,6 9,6,%/( $7 7+( 72P 2) 7+(5227 %$//. ,) 7+( 5227 )/$5( ,6 127 9,6,%/(7+( 62,/ 6+$// %( 5(029(' ,1 $ /(9(/0$11(5 )520 7+( 5227 %$// 72 :+(5( 7+(),567 0$,1 25'(5 5227 12" ',$. 25 /$5*(5 (0(5*(6 )520 7+( 7581.. 6(7 0$,1 25'(55227 1" +,*+(5 7+$1 $'-$&(17 *5$'(. '2127 &29(5 72P 2) 5227 %$// :,7+ 62,/.P/$&( 5227 %$// 21 81',6785%(' 25&20P$&7(' 62,/7$0P 62,/ $5281' 5227 %$// %$6( ),50/<:,7+ )227 P5(6685( 62 7+$7 5227 %$//'2(6 127 6+,)74" %8,/7-8P ($57+ 6$8&(5 %(<21' ('*( 2)5227 %$//P/$17,1* P,7 72 %( 7:272 ),9( 7,0(6 7+( ',$0(7(52) 7+( 5227 %$// 6/2P('P5(P$5(' P/$17,1* 62,/P(5 6P(&6' ',$0(7(508/&+ 5,1*5(029( %85/$P 7:,1( 52P( $1' :,5( )52072P +$/) 2) 5227 %$//('*( &21',7,21 9$5,(65()(5 72 P/$14" 25*$1,& 08/&+ '2 127 P/$&( 08/&+ ,1&217$&7 :,7+ 75(( 7581.6&$5,)< 6,'(6 2) 75(( P,7:,7+ 6P$'( %< +$1' 72 %,1':,7+ P5(P$5(' P/$17,1* 62,/DETAIL - TREE PLANTING3/4" = 1'-0"P529,'( ,167$// 52'(17 P527(&7,21.12"+$5':,5( &/27+ 0(6+ &</,1'(5 8" ',$. 25*5($7(5 ; 36" +*7 67$.( ,1 P/$&(. P(5 6P(&P-21.261-0144" &21&5(7( 81,7 P$9(56 :/ P2/<0(5,&6$1' 6:(P7 -2,176 6(7 +$1' 7,*+71" :$6+(' 6$1' /(9(/,1* %$6(6" &20P$&7(' $**5(*$7( 68%%$6(&20P$&7(' 68%*5$'(P/$17,1* 9$5,(6- +2/' ),1,6+(' *5$'(1" %(/2: P$9(56 6(( P/$17,1* P/$16"P/$67,& P$9(5 5(675$,17 6<67(0CONCRETE UNIT PAVER1" = 1'-0")/86+$'-$&(17 P$9,1* 6(( P/$16127(&21&5(7( 81,7 P$9(56 6+$// %(,167$//(' ,1 $ 5$1'20 6,=( 5811,1*%21' P$77(51 86,1* 7+( 9$5,286/(1*7+6P-21.261-665+2/' ),1,6+(' *5$'( 12"%(/2: ('*(5- 6(( P/$1 )25('*( &21',7,21316" 0(7$/ ('*(5 :/ 67$.(P/$17,1* $5($- 6(( P/$17,1*P/$1785)- 6(( P/$17,1* P/$1STEEL EDGING1 1/2" = 1'-0"P-21.261-65P-21.261-656P5(P$5( P/$17,1* 62,/ )257+( (17,5( %('$PP/,&$7,21 2) P5(-(0(5*(17+(5%,&,'(3" 08/&+ '2 127 P/$&( ,1&217$&7 :,7+ 6+58% 67(0P5(P$5( %('$ 0,1. 4" '((P(57+$1 5227 %$//12" 0,1.6P$&,1*DETAIL - SHRUB PLANTING1" = 1'-0"('*( &21',7,21 9$5,(65()(5 72 P/$1P/$17,1* 62,/ )25 6+58%66&$5,)< 6,'(6 $1' %27720 2) (17,5(%(' :,7+ 6P$'( %< +$1' 72 %,1':,7+ P/$17,1* 62,/81',6785%(' 68%*5$'(&217$,1(5 *52:1 0$7(5,$/6+$// +$9( 52276 +$1' /226(1('P-21.261-067CONCRETE PLANTER CURB1 1/2" = 1'-0"&20P$&7(' 0Q'27 &/$66 5 $**5(*$7(%$6(&.,.P. &21&5(7( &85% 1/4" &+$0)(5 21('*(6 7<P.(;P$16,21 -2,17 7<P. 2 4 %$5 (P2;< &2$7(' &217,18286./$1'6&$P( %(' 3" 0,1 '(P7++$5':22' 08/&+6(( P/$17,1* P/$1&20P$&7(' 68%*5$'(P$9,1* &21',7,21 9$5,(6 5()(5 72 P/$18"8"10"1'-6"6"8P-21.261-07 62,469 SF PARKING 74 SF COMMON / CIRCULATION 464 SF MECH / ELEC 150 SF COMMON / CIRCULATION 23' - 0"18' - 0"18' - 0"23' - 0"18' - 0"24' - 0" 1 8 ' - 0 " 2 3 ' - 0 " 1 8 ' - 0 " 18' - 0"23' - 0"18' - 0"18' - 0"23' - 0"18' - 0" 23' - 0"18' - 0" 23' - 4"16' - 0" MECH EXHAUST MECH INTAKE 805 SF MECH / ELEC 444 SF MECH / ELEC UNEXCAVATED 1" = 20'-0"A1-0 1 LEVEL P1 PLAN NORTH Signature Typed or Printed Name License #Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:11 PMA1-0 LEVEL P1 PLAN 221561.00 Author Checker 01/06/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 PARKING SCHEDULE - APARTMENT Type Level Count LEVEL P1 8'-0" x 18' - COMPACT LEVEL P1 7 8'-6" x 18' - COMPACT LEVEL P1 8 9'-0" x 18' - STANDARD LEVEL P1 126 9'-0' x 16' - COMPACT LEVEL P1 3 9'-0' x 18' - ADA LEVEL P1 4 148 LEVEL 1 8'-0" x 18' - COMPACT LEVEL 1 3 9'-0" x 18' - STANDARD LEVEL 1 38 9'-0' x 16' - COMPACT LEVEL 1 2 9'-0' x 18' - STANDARD LEVEL 1 1 44 LEVEL 2 8'-0" x 18' - COMPACT LEVEL 2 6 8'-6" x 18' - COMPACT LEVEL 2 5 9'-0" x 18' - STANDARD LEVEL 2 88 9'-0' x 16' - COMPACT LEVEL 2 2 9'-0' x 18' - ADA LEVEL 2 4 105 TOTAL STALLS:297 PARKING SCHEDULE - RETAIL Type Level Count LEVEL 1 8'-6" x 18' - COMPACT LEVEL 1 1 8'-6" x 18' - STANDARD LEVEL 1 3 9'-0" x 18' - STANDARD LEVEL 1 33 9'-0' x 16' - COMPACT LEVEL 1 1 9'-0' x 18' - ADA LEVEL 1 4 TOTAL STALLS:42 No. Description Date 8,571 SF AMENITY 2,840 SF RETAIL 3,222 SF RETAIL 832 SF AMENITY 4,000 SF RETAIL 18' - 0"23' - 0"18' - 0"23' - 0"18' - 0"23' - 0"18' - 0"23' - 0"18' - 0"18' - 0"23' - 0"18' - 0"24' - 0" 556 SF COMMON / CIRCULATION 77 SF COMMON / CIRCULATION 152 SF BOH 452 SF MECH / ELEC MECH EXHAUST 18' - 0"23' - 0"4' - 0"304 SF COMMON / CIRCULATION 21,298 SF PARKING 18,180 SF PARKING 374 SF STORAGE 143 SF COMMON / CIRCULATION 776 SF BOH 370 SF BOH 568 SF BOH 217 SF BOH CIRC LOADING COMMERCIAL TRASH/REC RESIDENTAIL TRASH/REC RESIDENTIAL AND COMMERCIAL PARKING ENTRANCE/EXIT MAIN RESIDENTIAL ENTRANCE / LOBBY COMMERCIAL / RES GUEST PARKING COMMERCIAL / RES GUEST PARKING RAMP DN TO RES PARKINGRAMP UP TO RES PARKINGSETBACK10' - 8"SETBACK5' - 3"SETBACK 17' - 4" SETBACK 15' - 9" SETBACK 15' - 3" S E T B A C K 9' - 8 " SETBACK 49' - 10" SETBACK 48' - 6" SETBACK 17' - 11" TRANSFORMER AREA WAY FOR GARAGE EXHAUST AREA WAY FOR GARAGE INTAKE AIR SETBACK16' - 3"SETBACK11' - 8"S E T B A C K T O L E V E L 2 -732' - 8 " PROPERTY LINE SETBACK15' - 11"SETBACK 14' - 3" PROPERTY LINE PROPERTY LINE PROPERTY LINE SETBACK 28' - 5"SETBACK18' - 2"SETBACK20' - 7"SETBACK6' - 0"BLAKE ROADE X C E L S IO R B L V D POCKET PARK TRANSFORMER 1" = 20'-0"A1-1 1 LEVEL 1 PLAN NORTH Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:14 PMA1-1 LEVEL 1 PLAN 221561.00 Author Checker 01/05/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 PARKING SCHEDULE - APARTMENT Type Level Count LEVEL P1 8'-0" x 18' - COMPACT LEVEL P1 7 8'-6" x 18' - COMPACT LEVEL P1 8 9'-0" x 18' - STANDARD LEVEL P1 126 9'-0' x 16' - COMPACT LEVEL P1 3 9'-0' x 18' - ADA LEVEL P1 4 148 LEVEL 1 8'-0" x 18' - COMPACT LEVEL 1 3 9'-0" x 18' - STANDARD LEVEL 1 38 9'-0' x 16' - COMPACT LEVEL 1 2 9'-0' x 18' - STANDARD LEVEL 1 1 44 LEVEL 2 8'-0" x 18' - COMPACT LEVEL 2 6 8'-6" x 18' - COMPACT LEVEL 2 5 9'-0" x 18' - STANDARD LEVEL 2 88 9'-0' x 16' - COMPACT LEVEL 2 2 9'-0' x 18' - ADA LEVEL 2 4 105 TOTAL STALLS:297 PARKING SCHEDULE - RETAIL Type Level Count LEVEL 1 8'-6" x 18' - COMPACT LEVEL 1 1 8'-6" x 18' - STANDARD LEVEL 1 3 9'-0" x 18' - STANDARD LEVEL 1 33 9'-0' x 16' - COMPACT LEVEL 1 1 9'-0' x 18' - ADA LEVEL 1 4 TOTAL STALLS:42 DEPARTMENT GROSS AREAS Area Department Area LEVEL P1 BOH 1,713 SF COMMON / CIRCULATION 225 SF PARKING 62,469 SF 64,406 SF LEVEL 1 AMENITY 9,403 SF BOH 2,910 SF COMMON / CIRCULATION 1,080 SF PARKING 39,478 SF RETAIL 10,062 SF 62,933 SF LEVEL 2 BOH 1,327 SF COMMON / CIRCULATION 2,782 SF PARKING 42,751 SF RESIDENTIAL 16,471 SF 63,332 SF LEVEL 3 AMENITY 2,722 SF BOH 646 SF COMMON / CIRCULATION 3,793 SF RESIDENTIAL 33,829 SF 40,991 SF LEVEL 4 BOH 648 SF COMMON / CIRCULATION 3,529 SF RESIDENTIAL 36,665 SF 40,842 SF LEVEL 5 BOH 648 SF COMMON / CIRCULATION 3,529 SF RESIDENTIAL 36,665 SF 40,842 SF LEVEL 6 BOH 648 SF COMMON / CIRCULATION 3,529 SF RESIDENTIAL 36,665 SF 40,842 SF LEVEL 7 AMENITY 745 SF BOH 609 SF COMMON / CIRCULATION 3,530 SF RESIDENTIAL 34,603 SF 39,487 SF 393,676 SF No. Description Date 464 SF STUDIO 1,011 SF 2 BED 1,052 SF 2 BED 1,318 SF 3 BED 684 SF 1 BED 1,011 SF 2 BED 1,040 SF 2 BED 1,041 SF 2 BED 506 SF STUDIO 970 SF 2 BED 969 SF 2 BED 797 SF 1 BED + DEN 464 SF STUDIO 774 SF 1 BED + DEN 1 6 ' - 0 "1 5 ' - 6 7 /8 "1 8 ' - 0 "1 4 ' - 0 " 2 8 ' - 0 " 1 8 ' - 0 " 2 8 ' - 0 " 1 8 ' - 0 " 2 8 ' - 0 "34' - 0"15' - 0"15' - 0"28' - 0"15' - 0"15' - 0"15' - 0"18' - 0"18' - 0"27' - 1 3/4"684 SF 1 BED 1,011 SF 2 BED 532 SF ALCOVE 684 SF 1 BED 5' - 4"712 SF TERRACE 521 SF STUDIO 18' - 11 1/4"34' - 0" 464 SF STUDIO 474 SF STUDIO 23' - 0"42,751 SF PARKING 337 SF POOL EQUIP 329 SF MECH / ELEC MECH EXHAUST INTAKE MECH EXHAUST 18' - 0"23' - 0"18' - 0"18' - 0"23' - 0"18' - 0"18' - 0"23' - 0"18' - 0"23' - 0"2,782 SF COMMON / CIRCULATION23' - 0"300 SF STORAGE 129 SF BOH SETBACK 48' - 6"SETBACK5' - 3"SETBACK12' - 6"SETBACK 17' - 4"SETBACK10' - 8"SETBACK15' - 6"SETBACK18' - 2"SETBACK9' - 10"S E T B A C K 3 3 ' - 9 " S E T B A C K 3 2 ' - 8 " SETBACK 41' - 5" 91 SF BOH 142 SF BOH 1" = 20'-0"A1-2 1 LEVEL 2 PLAN NORTH Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:15 PMA1-2 LEVEL 2 PLAN 221561.00 Author Checker 01/05/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 **UNIT MIX SUMMARY - OPTION 1) Name Qty % Area Min - Max SF 1 BED 97 39% 66,839 SF 645 SF ... 720 SF 1 BED + DEN 2 1% 1,572 SF 774 SF ... 797 SF 2 BED 80 32% 81,097 SF 904 SF ... 1,052 SF 3 BED 11 4% 14,087 SF 1,272 SF ... 1,318 SF ALCOVE 40 16% 21,656 SF 495 SF ... 597 SF STUDIO 20 8% 9,650 SF 464 SF ... 521 SF Grand total: 250 250 194,900 SF PARKING SCHEDULE - APARTMENT Type Level Count LEVEL P1 8'-0" x 18' - COMPACT LEVEL P1 7 8'-6" x 18' - COMPACT LEVEL P1 8 9'-0" x 18' - STANDARD LEVEL P1 126 9'-0' x 16' - COMPACT LEVEL P1 3 9'-0' x 18' - ADA LEVEL P1 4 148 LEVEL 1 8'-0" x 18' - COMPACT LEVEL 1 3 9'-0" x 18' - STANDARD LEVEL 1 38 9'-0' x 16' - COMPACT LEVEL 1 2 9'-0' x 18' - STANDARD LEVEL 1 1 44 LEVEL 2 8'-0" x 18' - COMPACT LEVEL 2 6 8'-6" x 18' - COMPACT LEVEL 2 5 9'-0" x 18' - STANDARD LEVEL 2 88 9'-0' x 16' - COMPACT LEVEL 2 2 9'-0' x 18' - ADA LEVEL 2 4 105 TOTAL STALLS:297 No. Description Date 66' - 0" 30' - 4"5' - 4"30' - 4"66' - 0"30' - 4"5' - 4"30' - 4"66' - 0"30' - 4"5' - 4"30' - 4"645 SF 1 BED 1,031 SF 2 BED 977 SF 2 BED 1,285 SF 3 BED 597 SF ALCOVE 485 SF STUDIO 687 SF 1 BED 687 SF 1 BED 1,016 SF 2 BED 498 SF ALCOVE 698 SF 1 BED 983 SF 2 BED 698 SF 1 BED 546 SF ALCOVE 1,007 SF 2 BED 546 SF ALCOVE 698 SF 1 BED 1,031 SF 2 BED1,031 SF 2 BED 648 SF 1 BED 952 SF 2 BED 720 SF 1 BED 698 SF 1 BED 698 SF 1 BED 904 SF 2 BED 698 SF 1 BED 698 SF 1 BED 698 SF 1 BED 1,031 SF 2 BED 698 SF 1 BED478 SF STUDIO 1,279 SF 3 BED 1,045 SF 2 BED 697 SF 1 BED 1,030 SF 2 BED 697 SF 1 BED 1,031 SF 2 BED 2,081 SF AMENITY 546 SF ALCOVE 698 SF 1 BED 531 SF ALCOVE 1,015 SF 2 BED 648 SF 1 BED 546 SF ALCOVE 641 SF AMENITY 2 0 ' - 0 " 2 0 ' - 0 " 2 3 ' - 0 " 1 6 ' - 0 " 2 3 ' - 0 " 3 4 ' - 0 " 2 3 ' - 0 " 3 2 ' - 0 "18' - 0"23' - 0"34' - 0"23' - 0"18' - 0"30' - 10 1/2"18' - 0"18' - 0"18' - 0"23' - 0"32' - 0"SWIMMING POOL 40' - 0"14' - 7 1/8"32' - 0"23' - 0"376 SF MECH / ELEC 139 SF MECH / ELEC 132 SF BOH 3,793 SF COMMON / CIRCULATION 13,981 SF TERRACE SPA SETBACK25' - 1"SETBACK30' - 8"SETBACK28' - 7"S E T B A C K 3 2 ' - 8 " SETBACK 48' - 10" S E T B A C K 3 3 ' - 9 " U N I T P A T IO S U N I T P A T IO S U N IT P A T IO S U N IT P A T IO S UNIT PATIOS UNIT PATIOS SETBACK9' - 8"29' - 2" SETBACK 25' - 3" SETBACK 17' - 2" SETBACK 16' - 4" SETBACK 14' - 8"SETBACK16' - 4"SETBACK20' - 4"11' - 8"SETBACK12' - 11"UNIT PATIOSSETBACK 50' - 2" 1" = 20'-0"A1-3 1 LEVEL 3 PLAN NORTH Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:17 PMA1-3 LEVEL 3 PLAN 221561.00 Author Checker 01/05/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 **UNIT MIX SUMMARY - OPTION 1) Name Qty % Area Min - Max SF 1 BED 97 39% 66,839 SF 645 SF ... 720 SF 1 BED + DEN 2 1% 1,572 SF 774 SF ... 797 SF 2 BED 80 32% 81,097 SF 904 SF ... 1,052 SF 3 BED 11 4% 14,087 SF 1,272 SF ... 1,318 SF ALCOVE 40 16% 21,656 SF 495 SF ... 597 SF STUDIO 20 8% 9,650 SF 464 SF ... 521 SF Grand total: 250 250 194,900 SF No. Description Date 66' - 0" 30' - 4"5' - 4"30' - 4"66' - 0"30' - 4"5' - 4"30' - 4"66' - 0" 30' - 4" 5' - 4" 30' - 4"66' - 0"30' - 4"5' - 4"30' - 4"645 SF 1 BED 1,031 SF 2 BED 980 SF 2 BED 1,272 SF 3 BED 699 SF 1 BED 485 SF STUDIO 687 SF 1 BED 687 SF 1 BED 1,015 SF 2 BED 497 SF ALCOVE 698 SF 1 BED 981 SF 2 BED 698 SF 1 BED 546 SF ALCOVE 1,006 SF 2 BED 545 SF ALCOVE 698 SF 1 BED 1,031 SF 2 BED1,031 SF 2 BED 649 SF 1 BED 951 SF 2 BED 583 SF ALCOVE 698 SF 1 BED 698 SF 1 BED 1,042 SF 2 BED 698 SF 1 BED 698 SF 1 BED 698 SF 1 BED 1,031 SF 2 BED 698 SF 1 BED 478 SF STUDIO 1,279 SF 3 BED 1,045 SF 2 BED 697 SF 1 BED 1,030 SF 2 BED 697 SF 1 BED 1,031 SF 2 BED 697 SF 1 BED 546 SF ALCOVE 698 SF 1 BED 485 SF STUDIO 532 SF ALCOVE 1,020 SF 2 BED 34' - 0"23' - 0"34' - 0"23' - 0"34' - 0" 23' - 0"23' - 0"23' - 0"34' - 0"23' - 0" 1,015 SF 2 BED 110°3 2 ' - 0 " 2 3 ' - 0 " 3 4 ' - 0 " 2 3 ' - 0 "1 6 ' - 0 "2 3 ' - 0 " 2 0 ' - 0 "2 0 ' - 0 " 649 SF 1 BED 18' - 0"23' - 0"34' - 0"23' - 0"18' - 0"32' - 0"23' - 0"18' - 0"18' - 0"18' - 0"546 SF ALCOVE 3 6 ' - 0 " 2 3 ' - 0 " 2 3 ' - 0 " 2 5 ' - 0 " 3 3 ' - 0 " 4 0 ' - 0 " 40' - 0" 376 SF MECH / ELEC 139 SF MECH / ELEC 132 SF BOH 3,529 SF COMMON / CIRCULATION 545 SF ALCOVE 1" = 20'-0"A1-4 1 LEVEL 4-6 PLAN NORTH Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:18 PMA1-4 LEVEL 4-6 PLAN 221561.00 Author Checker 01/05/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 **UNIT MIX SUMMARY - OPTION 1) Name Qty % Area Min - Max SF 1 BED 97 39% 66,839 SF 645 SF ... 720 SF 1 BED + DEN 2 1% 1,572 SF 774 SF ... 797 SF 2 BED 80 32% 81,097 SF 904 SF ... 1,052 SF 3 BED 11 4% 14,087 SF 1,272 SF ... 1,318 SF ALCOVE 40 16% 21,656 SF 495 SF ... 597 SF STUDIO 20 8% 9,650 SF 464 SF ... 521 SF Grand total: 250 250 194,900 SF No. Description Date 645 SF 1 BED 698 SF 1 BED 979 SF 2 BED 1,272 SF 3 BED 700 SF 1 BED 485 SF STUDIO 687 SF 1 BED 687 SF 1 BED 1,014 SF 2 BED 498 SF ALCOVE 698 SF 1 BED 982 SF 2 BED 698 SF 1 BED 546 SF ALCOVE 1,009 SF 2 BED 544 SF ALCOVE 698 SF 1 BED 745 SF TERRACE745 SF AMENITY 495 SF ALCOVE 951 SF 2 BED 581 SF ALCOVE 698 SF 1 BED 698 SF 1 BED 1,042 SF 2 BED 698 SF 1 BED 698 SF 1 BED 698 SF 1 BED 1,031 SF 2 BED 698 SF 1 BED 478 SF STUDIO 1,279 SF 3 BED 1,046 SF 2 BED 697 SF 1 BED 1,030 SF 2 BED 697 SF 1 BED 1,031 SF 2 BED 697 SF 1 BED 698 SF 1 BED 1,031 SF 2 BED 485 SF STUDIO 533 SF ALCOVE 1,020 SF 2 BED 1,015 SF 2 BED 649 SF 1 BED 546 SF ALCOVE 2 0 ' - 0 " 2 0 ' - 0 " 2 3 ' - 0 " 1 6 ' - 0 " 3 4 ' - 0 " 2 3 ' - 0 " 2 3 ' - 0 " 3 2 ' - 0 " 376 SF MECH / ELEC 3,530 SF COMMON / CIRCULATION 96 SF BOH137 SF MECH / ELEC 545 SF ALCOVE23' - 4"1" = 20'-0"A1-5 1 LEVEL 7 PLAN NORTH Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:19 PMA1-5 LEVEL 7 PLAN 221561.00 Author Checker 01/05/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 **UNIT MIX SUMMARY - OPTION 1) Name Qty % Area Min - Max SF 1 BED 97 39% 66,839 SF 645 SF ... 720 SF 1 BED + DEN 2 1% 1,572 SF 774 SF ... 797 SF 2 BED 80 32% 81,097 SF 904 SF ... 1,052 SF 3 BED 11 4% 14,087 SF 1,272 SF ... 1,318 SF ALCOVE 40 16% 21,656 SF 495 SF ... 597 SF STUDIO 20 8% 9,650 SF 464 SF ... 521 SF Grand total: 250 250 194,900 SF No. Description Date ELEVATOR OVERRUN ROOF ACCESS HATCH ELEVATOR OVERRUN COMMERCIAL EXHAUST LEVEL 3 COURTYARD BELOW LEVEL 3 ROOF BELOW LEVEL 7 TERRACE LEVEL 3 UNIT TERRACE BELOW LEVEL 3 UNIT TERRACE BELOW LEVEL 1 COMMERCIAL TRELLIS BELOW AREA AVAILABLE FOR PV SOLAR ARRAY PLAN NORTH Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:20 PMA1-6 ROOF PLAN 221561.00 Author Checker 02/11/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 1" = 20'-0"A1-6 1 ROOF LEVEL No. Description D ate Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:20 PMA3-1 PERSPECTIVE VIEWS 221561.00 Author Checker 01/31/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 COMMERCIAL PATIO ON BLAKE ROAD VIEW WEST ON EXCELSIOR BOULEVARD VIEW EAST ON EXCELSIOR BOULEVARD POCKET PARK No. Description Date LEVEL 1 100' - 0" LEVEL 2 114' - 4" LEVEL 3 125' - 8" LEVEL 4 137' - 4" LEVEL 5 148' - 0" LEVEL 6 158' - 8" LEVEL 7 169' - 4" LEVEL P1 89' - 6" ROOF LEVEL 180' - 0" 20' - 2"10' - 1"7' - 9"9' - 0"14' - 2"9' - 0"13' - 2"10' - 0"24' - 9"9' - 0"17' - 6"11' - 3"9' - 0"10' - 0"7' - 6"7' - 10"10' - 1"7' - 10"10' - 1"7' - 10"16' - 3"11' - 0"31' - 4" METAL TILE FIBER CEMENT LAP SIDING FACE BRICK METAL PANEL 36' - 1"7' - 4"39' - 5"11' - 6"35' - 2"7' - 4"36' - 7"17' - 10"8' - 10"6' - 7"25' - 2"14' - 1"7' - 4"32' - 6"10' - 8"72' - 4"9' - 4"16' - 4"83' - 0"WALL AREA = 1,715 SF WINDOW AREA = 1,280 SF TRANSPARENCY = 75% STEEL TRELLISALUMINUM STOREFRONT AT LEVEL 1 LEVEL 1 100' - 0" LEVEL 2 114' - 4" LEVEL 3 125' - 8" LEVEL 4 137' - 4" LEVEL 5 148' - 0" LEVEL 6 158' - 8" LEVEL 7 169' - 4" LEVEL P1 89' - 6" ROOF LEVEL 180' - 0"10' - 8"10' - 8"10' - 8"10' - 8"11' - 8"11' - 4"14' - 4"10' - 6"FIBER CEMENT LAP SIDING PREFINISHED METAL COPING 16'28'11'13'9'13'9'18'9'15'11'10'9'11'9' 26' FACE BRICK METAL TILE METAL PANEL 19' - 11"23' - 2"13' - 6"9' - 2"19' - 7"18' - 1"21' - 1"7' - 7"10' - 6"9' - 1"16' - 8"32' - 3" ELEVATION BEYOND COMPOSITE WINDOWS AND SLIDING GLASS DOORS ALUMINUM STOREFRONT AT LEVEL 1 PREFINISHED ALUMINUM BALCONY METAL PANEL PREFINISHED METAL RAILING 83' - 0"30' - 4"16' - 0"68' - 8"84' - 8"WALL AREA = 1,260 SF WINDOW AREA = 650 SF TRANSPARENCY = 52% Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:25 PMA3-2 SOUTH AND EAST BUILDING ELEVATIONS 221561.00 Author Checker 01/31/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 3/32" = 1'-0"A3-2 1 EAST ELEVATION 3/32" = 1'-0"A3-2 2 SOUTH ELEVATION No. Description D ate LEVEL 1 100' - 0" LEVEL 2 114' - 4" LEVEL 3 125' - 8" LEVEL 4 137' - 4" LEVEL 5 148' - 0" LEVEL 6 158' - 8" LEVEL 7 169' - 4" LEVEL P1 89' - 6" ROOF LEVEL 180' - 0"83' - 0"15' - 5"4' - 0"24' - 5"10' - 0"10' - 11"10' - 2"9' - 0"16' - 7"9' - 0"15' - 0"8' - 0"6' - 11"16' - 0"4' - 0"24' - 10"10' - 4"10' - 11" NOT INCLUDED IN MATERIAL CALCUATIONS COURTYARD ELEVATION BEYOND 4' - 0"5' - 2"11' - 1"10' - 0"21' - 0"11' - 0"6' - 6"6' - 0"7' - 0"18' - 1"10' - 0"10' - 11"24' - 1"11' - 0"10' - 0"18' - 0"17' - 0"11' - 0"10' - 0"13' - 3"24' - 0"28' - 2"7' - 4"28' - 0"13' - 4" FACE BRICK METAL PANEL METAL TILE COMPOSITE WINDOWS PREFINISHED METAL BALCONIES METAL PANEL FIBER CEMENT LAP SIDING ALUMINUM WINDOWS METAL PANEL10' - 8"43' - 8"28' - 8"WALL AREA = 1,565 SF WINDOW AREA = 470 SF TRANSPARENCY = 30% STREETFRONT LEVEL 1 100' - 0" LEVEL 2 114' - 4" LEVEL 3 125' - 8" LEVEL 4 137' - 4" LEVEL 5 148' - 0" LEVEL 6 158' - 8" LEVEL 7 169' - 4" LEVEL P1 89' - 6" ROOF LEVEL 180' - 0" 11' - 1"8' - 11"25' - 0"9' - 0"12' - 6"5' - 0"8' - 4"9' - 1"16' - 1"9' - 0"16' - 7"9' - 1"14' - 3"9' - 0"20' - 4"9' - 0"17' - 8"9' - 0"18' - 1"9' - 0"14' - 5" 23' - 1"23' - 11"18' - 1"5' - 7"18' - 1"14' - 0"11' - 8"23' - 4"24' - 1"18' - 0"27' - 0"7' - 4"22' - 0"3' - 0"22' - 3" Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 3/18/2022 4:00:40 PMA3-3 WEST AND NORTH BUILDING ELEVATIONS 221561.00 LB ESG 02/06/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN Schematic Design 3/17/22 3/32" = 1'-0"A3-3 1 WEST ELEVATION 3/32" = 1'-0"A3-3 2 NORTH ELEVATION No. Description Date TRANSFORMER SCREEN METAL PANEL AND WINDOWS EXTENDED TO BLDG EDGE GARAGE WINDOWS MODIFIED TO BE MORE LIKE RESIDENTIAL WINDOWS BY MATCHING HEIGHT, ADDING METAL LINTEL AND HORIZONTAL MULLION HORIZONTAL MULLION ADDED AT FIRST FLOOR GARAGE WINDOWS TO ALIGN WITH RETAIL WINDOW DESIGN LAND USE REVISIONS 3/24/2022 KNOCK-OUT PANEL FOR POTENTIAL NORTHERN GARAGE ENTRANCE DECORATIVE METAL TRELLIS RECESSED FACE BRICK DECORATIVE METAL TRELLIS RECESSED FACE BRICK GARAGE WINDOWS MODIFIED TO BE MORE LIKE RESIDENTIAL WINDOWS BY MATCHING HEIGHT, ADDING METAL LINTEL AND HORIZONTAL MULLION HORIZONTAL MULLION ADDED AT FIRST FLOOR GARAGE WINDOWS Signature Typed or Printed Name License #Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/17/2022 8:35:54 AMA3-4 EXTERIOR MATERIALS 221561.00 Author Checker 02/18/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 No. Description Date FACE BRICK - PRIMARY METAL TILE FIBER CEMENT LAP SIDING FACE BRICK - ACCENT METAL PANEL Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed architect under the laws of the State of Minnesota 2/16/2022 5:15:30 PMA3-5 SHADOW STUDIES 221561.00 Author Checker 02/11/22 BLAKE STATION SITE B BLAKE STATION SITE B Hopkins, MN LUA Submittal 2/18/2022 No. Description Date FUTURE DRIVEWAY T C TC 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.9 1.8 1.5 0.4 0.1 0.1 0.2 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 1.5 5.5 9.8 5.8 1.2 0.2 0.4 1.4 1.6 0.7 0.2 0.2 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.6 3.3 14.1 1.1 0.2 1.1 5.8 7.2 2.2 0.4 1.0 2.1 1.5 0.4 0.1 0.1 0.2 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 2.4 8.1 11.6 2.7 0.4 3.2 9.3 5.4 0.9 0.2 0.3 1.3 1.8 0.8 0.2 0.2 0.3 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.9 0.7 1.0 7.4 0.7 0.1 0.8 5.3 8.0 2.7 0.4 0.8 2.1 1.7 0.5 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 1.8 0.0 3.6 10.8 3.5 0.4 2.5 9.0 6.5 1.2 0.2 0.1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.8 3.5 6.3 6.5 9.0 1.0 0.1 0.1 0.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.9 6.8 7.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.0 6.7 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 2.1 5.1 7.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 2.8 6.3 1.1 0.7 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 3.2 0.0 8.1 8.3 3.4 0.7 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.0 3.7 7.4 7.9 4.8 0.9 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.3 5.2 8.4 8.0 3.9 2.0 0.6 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 1.8 6.2 9.3 2.1 2.8 1.0 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 2.4 6.1 8.6 10.0 2.6 0.5 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 1.9 5.2 6.5 8.3 2.3 0.5 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 2.6 4.8 3.6 1.9 0.5 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 1.5 4.4 6.2 5.8 11.6 4.9 1.1 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 1.8 5.9 8.5 11.7 4.8 1.0 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 2.1 6.9 10.5 9.7 2.2 3.5 2.1 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.7 3.2 6.6 8.6 7.9 6.0 0.5 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 2.5 9.6 4.1 6.4 5.9 4.0 3.5 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.5 2.9 5.0 6.9 1.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.1 2.7 4.2 6.4 1.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.5 3.1 7.0 2.2 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.3 3.6 3.8 4.3 1.0 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.5 3.0 1.7 7.2 9.4 3.3 0.7 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.4 2.2 6.9 8.2 3.3 0.9 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.5 1.0 7.1 1.5 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 6.9 3.8 0.9 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.4 0.6 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.6 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 4.3 1.4 0.3 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 10.9 2.7 0.5 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 6.1 2.0 0.5 0.2 0.1 0.0 0.0 0.0 0.1 0.2 0.2 0.3 0.4 0.5 0.5 0.4 0.3 0.3 0.3 0.3 0.3 7.3 2.7 0.6 0.2 0.1 0.1 0.0 0.0 0.1 0.2 0.3 0.4 0.6 0.7 0.7 0.5 0.4 0.4 0.5 0.5 0.4 12.0 3.6 0.7 0.2 0.1 0.1 0.0 0.0 0.2 0.2 0.3 0.5 0.7 0.9 0.9 0.4 0.4 0.5 0.7 0.6 0.5 4.5 1.8 0.5 0.2 0.1 0.1 0.0 0.0 0.2 0.3 0.4 0.6 0.9 1.1 0.9 0.4 0.4 0.4 0.8 0.8 0.6 4.1 2.2 0.6 0.2 0.1 0.1 0.0 0.0 0.2 0.3 0.5 0.7 0.9 1.1 0.9 0.5 0.4 0.7 0.8 0.7 11.0 4.9 1.0 0.2 0.1 0.1 0.0 0.0 0.2 0.3 0.5 0.7 1.0 1.1 0.7 0.5 0.5 0.6 0.7 0.6 9.0 3.5 0.7 0.2 0.1 0.1 0.0 0.0 0.2 0.3 0.5 0.7 1.0 1.0 0.7 0.5 0.5 0.4 0.6 0.6 0.6 1.0 0.8 0.3 0.1 0.1 0.1 0.0 0.0 0.2 0.3 0.5 0.7 0.9 0.8 0.4 0.5 0.4 0.7 0.8 0.6 1.4 1.4 0.5 0.2 0.1 0.1 0.0 0.0 0.2 0.3 0.4 0.6 0.7 0.6 0.4 0.5 0.6 0.8 0.7 0.6 10.4 5.7 1.4 0.3 0.1 0.1 0.0 0.0 0.2 0.2 0.3 0.4 0.5 0.4 0.3 0.4 0.4 0.6 0.6 0.6 0.5 7.1 1.5 0.3 0.1 0.1 0.0 0.0 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 2.0 0.6 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.2 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 3.2 1.8 0.5 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 5.1 1.0 0.2 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 10.3 4.1 0.8 0.2 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 1.2 1.0 0.4 0.2 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.1 2.0 1.8 0.6 0.2 0.1 0.1 0.0 0.1 0.1 0.2 0.3 0.4 0.5 0.5 0.4 0.3 0.2 0.2 11.5 6.7 1.6 0.3 0.1 0.1 0.0 0.1 0.1 0.2 0.3 0.5 0.6 0.6 0.4 0.4 0.7 1.0 11.1 6.7 1.5 0.3 0.1 0.1 0.0 0.1 0.1 0.2 0.3 0.4 0.4 0.4 0.3 0.3 1.0 8.7 4.7 0.3 0.8 5.4 1.3 0.8 5.6 1.4 0.7 3.1 9.1 1.6 0.6 0.1 0.1 0.0 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.3 1.1 1.2 0.4 0.3 1.1 1.3 0.5 0.3 1.0 1.9 0.2 0.6 0.7 0.2 0.1 0.2 0.6 0.7 0.3 0.2 0.2 0.6 0.7 0.3 0.3 0.6 0.9 0.3 1.6 0.7 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.2 0.3 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.3 0.3 0.2 8.1 2.4 0.4 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.2 0.2 10.8 2.8 0.5 0.1 0.1 0.0 0.2 0.2 0.3 0.4 0.3 0.1 2.7 1.1 0.3 0.1 0.1 0.0 0.1 0.2 0.2 0.9 3.9 0.1 1.7 1.0 0.3 0.1 0.1 0.0 0.1 0.1 0.2 1.0 9.0 9.7 3.5 0.7 0.2 0.1 0.0 0.1 0.1 0.2 0.7 1.1 0.1 4.2 0.8 0.2 0.1 0.0 0.1 0.1 0.2 0.3 0.2 0.1 2.9 1.4 0.4 0.1 0.1 0.0 0.1 0.1 0.1 0.4 0.3 0.1 0.4 0.4 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.9 5.8 0.0 3.4 2.4 0.7 0.2 0.1 0.0 0.0 0.1 0.1 1.0 7.7 10.7 6.9 1.5 0.3 0.1 0.0 0.0 0.1 0.1 0.6 0.6 0.0 9.7 5.0 1.1 0.2 0.1 0.0 0.0 0.1 0.1 0.3 0.3 1.8 0.8 0.8 0.3 0.1 0.1 0.0 0.0 0.1 0.1 0.6 1.0 2.4 6.0 2.7 0.6 0.4 2.3 6.1 2.9 0.6 1.0 4.2 5.2 1.5 0.3 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 1.0 8.0 1.4 3.1 3.2 1.6 0.5 0.4 1.4 1.7 0.6 1.3 3.2 3.2 1.4 0.2 0.7 2.2 3.6 2.6 1.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.9 5.8 0.6 1.1 1.2 1.5 8.8 4.5 0.7 1.0 1.1 1.0 6.5 8.0 1.7 1.3 0.4 0.9 1.2 0.6 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.4 0.2 0.3 0.4 0.8 1.1 1.0 0.5 0.4 0.4 0.6 1.0 1.1 0.9 1.2 6.3 5.4 0.6 1.4 6.8 4.1 0.5 0.4 0.7 3.6 4.6 1.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.5 0.4 0.4 0.5 0.5 0.3 0.2 0.3 0.3 0.3 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.9 1.4 0.7 0.3 0.3 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 4.2 6.7 2.6 0.6 1.3 2.0 1.1 0.3 0.1 0.1 0.1 0.0 0.0 8.4 10.1 4.2 0.9 4.8 9.1 3.6 0.5 0.2 0.1 0.1 0.1 0.0 4.4 0.5 0.5 0.5 0.2 0.1 0.1 0.7 0.2 0.1 1.5 0.1 0.3 0.8 0.1 0.0 1.0 3.0 2.5 2.6 11.0 8.6 0 40'20' 1"=20'-0" 10' Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min East Property Line Illuminance Fc 0.26 2.0 0.0 N.A. N.A. North Property Line Illuminance Fc 0.54 3.7 0.1 5.40 37.00 Northeast Egress Path Illuminance Fc 2.67 8.9 0.3 8.90 29.67 Northwest Egress Path Illuminance Fc 3.27 10.1 0.3 10.90 33.67 Overall Site Illuminance Fc 0.68 13.4 0.0 N.A. N.A. South Property Line Illuminance Fc 0.34 1.6 0.0 N.A. N.A. West Property Line Illuminance Fc 0.14 0.7 0.0 N.A. N.A. W2 9' 0" W2 9' 0" W1 9' 0" W3 14' 0'' W3 14' 0'' W3 14' 0'' W3 14' 0'' B2 3' 0'' B2 3' 0'' B2 3' 0'' B2 3' 0'' B2 3' 0'' B2 3' 0'' B2 3' 0'' W5 14' 0''W4 14' 0'' W4 8' 6" W4 8' 6" W4 8' 6" W1 8' 6" W4 8' 6" W4 8' 6" W4 8' 6" W4 8' 6" W1 8' 6" W1 8' 6" D2 14' 0'' D2 14' 0'' D2 14' 0'' W4 8' 6" W4 8' 6" W4 8' 6" W4 8' 6" W1 8' 6" W1 8' 6" W1 8' 6" W1 8' 6" W1 8' 6" W1 8' 6" W1 8' 6" W1 8' 6" D1 14' 0'' D1 14' 0'' D1 14' 0'' D1 14' 0'' D1 14' 0'' D1 14' 0'' W1 8' 6" W1 8' 6" B2 3' 0'' B1 14' 0'' B1 14' 0'' B1 14' 0'' B1 14' 0'' B1 14' 0'' B1 14' 0'' W1 14' 0'' W1 14' 0'' B2 3' 0'' A. REFER TO SHEETS E0.2P, E0.3P, AND E0.4P FOR FIXTURE SCHEDULES, DETAILS, AND CUTSHEETS. B. LIGHTING LEVELS SHOWN ARE MAINTAINED. LIGHT LOSS FACTOR OF 0.90 WAS USED TO ACCOUNT FOR DIRT AND LUMEN DEPRECIATION. C. WALL SCONCE AND DOWNLIGHT MOUNTING HEIGHTS SHOWN ARE TO BOTTOM OF FIXTURE. D. BOLLARD MOUNTING HEIGHTS SHOWN ARE TO TOP OF FIXTURE. GENERAL NOTES: PLAN NORTH Signature Typed or Printed Name License #Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed professional engineer under the laws of the State of Minnesota E0.1P ELECTRICAL SITE PHOTOMETRIC 4452.0002 MBS JJA 02/18/22 Blake Station Site B Blake Station Site B Hopkins, MN LUA Submittal 02/18/2022 SCALE:1" = 20'-0" ELECTRICAL SITE PHOTOMETRIC1 No. Description D ate BOLLARD BASE TOP OF GRADE BOND TO GROUND LUG #4 B.C. TYPICAL HOT DIPPED GALVANIZED ANCHOR BOLT PROVIDED BY BOLLARD MANUFACTURER. REFER TO STRUCTURAL DETAILS FOR BASE DIMENSIONS AND REBAR SIZE/SPACING BOND TO REBAR 3000K B2 3' TALL, 8'' WIDE NOTCH LED BOLLARD. DIE CAST LOW COPPER ALUMINUM HOUSING. IP65 RATED. UV STABILIZED POLYCARBONATE LENS. ASYMETRICAL THROW. 400 DELIVERED LUMENS. POINT TOWARDS PATHWAY. FINISH TO BE SELECTED BY LANDSCAPE. UNV LED N/A 10 SELUX NT-3-LG4500 3000K D1 RECESSED 2,000 LUMEN 6" ROUND LED DOWNLIGHT. HIGH EFFICIENCY LED LIGHT ENGINE. CLEAR SEMI-DIFFUSE ALZAK REFLECTOR. TRIM TO MATCH CEILING FINISH. FINISH TO BE SELECTED BY ARCHITECT. UNV LED N/A 22 PRESCOLITE LF6SL-6LFSL20L30K8 3000K W4 4 7/8" WIDE, 12 1/2" TALL ROUND LED WALL SCONCE. DIE-CAST ALUMINUM HOUSING. IP65 RATED. WET LOCATION LISTED. DOWN ONLY LIGHT LED MODULE, AWAY FROM WALL DOWN DISTRIBUTION. 2,000 NOMINAL LUMENS. BLACK FINISH. UNV LED N/A 17 WAC LIGHTING DS-WD0534-F930A-BK 3000K D2 7'' TALL LED DOWNLIGHT. ALUMINUM CONSTRUCTION. IP66 RATED. CLEAR LENS. 40 DEGREE FLOOD LIGHT DISTRIBUTION. 825 DELIVERED LUMENS, 90 CRI. INSTALL IT IN BETWEEN TRELIS' OVERHEAD BEAMS. FINISH TO BE SELECTED BY ARCHITECT. UNV LED N/A 13 B-K LIGHTING SM-DE-TR-X102-FL 3000K 3000K W3 4' LINEAR WALL MOUNTED LED FIXTURE. EXTRUDED ALUMINUM FIXTURE WITH 6" FIXED BRACKET. SYMMETRIC 30 DEGREE -60 DEGREE BEAM SPREAD. 1,600 DELIVERED LUMENS. WET LOCATION LISTED. TILT FIXTURE 30 DEGREES TOWARDS WALL. BRACKET SHALL BE 1' LONG. BLACK FINISH. UNV LED N/A 16 SPI LIGHTING SEW12145-4FT-L16W-120-277V-3000K-LBK6-SMB 3000K W5 4 7/8" WIDE, 12 1/2" TALL ROUND LED WALL SCONCE. DIE-CAST ALUMINUM HOUSING. IP65 RATED. WET LOCATION LISTED. DOWN ONLY LIGHT LED MODULE, TOWARDS WALL DOWN DISTRIBUTION. 2,000 NOMINAL LUMENS. BLACK FINISH. UNV LED N/A 17 WAC LIGHTING DS-WD0534-F930B-BK 3000K W1 4 7/8" WIDE, 12 1/2" TALL ROUND LED WALL SCONCE. DIE-CAST ALUMINUM HOUSING. IP65 RATED. WET LOCATION LISTED. UP/DOWN LIGHT LED MODULE, AWAY FROM WALL UP/DOWN DISTRIBUTION. 2,000 NOMINAL LUMENS. BLACK FINISH. UNV LED N/A 34 WAC LIGHTING DS-WD0534-F930A-BK 3000K W2 4 7/8" WIDE, 12 1/2" TALL ROUND LED WALL SCONCE. DIE-CAST ALUMINUM HOUSING. IP65 RATED. WET LOCATION LISTED. UP/DOWN LIGHT LED MODULE, TOWARDS WALL UP/DOWN DISTRIBUTION. 2,000 NOMINAL LUMENS. BLACK FINISH. UNV LED N/A 34 WAC LIGHTING DS-WD0534-F930B-BK LIGHT FIXTURE SCHEDULE FIXT. TYPE DESCRIPTION VOLTAGE LAMPS VA/ FIXT.MANUFACTURER CATALOG NUMBER TYPE QTY./ FIXT. B1 14' TALL COLUMN LED BOLLARD. 2' LIT SECTION ON TOP OF FIXTURE WITH UV DIFFUSER. IP66 RATED. ONE LIGHT ENGINE, 1,300 DELIVERED LUMENS. POINT TOWARDS PATHWAY. FINISH TO BE SELECTED BY LANDSCAPE. UNV LED N/A 13 SELUX MTRCL-14-2-1B30-30 Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed professional engineer under the laws of the State of Minnesota E0.2P ELECTRICAL SITE PHOTOMETRIC DETAILS 4452.0002 MBS JJA 02/18/22 Blake Station Site B Blake Station Site B Hopkins, MN LUA Submittal 02/18/2022 NO SCALE BOLLARD BASE DETAIL1 NO SCALE FIXTURE TYPE B12 NO SCALE FIXTURE TYPE B23 No. Description D ate Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed professional engineer under the laws of the State of Minnesota E0.3P ELECTRICAL SITE PHOTOMETRIC DETAILS 4452.0002 MBS JJA 02/18/22 Blake Station Site B Blake Station Site B Hopkins, MN LUA Submittal 02/18/2022 NO SCALE FIXTURE TYPE D11 NO SCALE FIXTURE TYPE D22 NO SCALE FIXTURE TYPE W13 NO SCALE FIXTURE TYPE W24 No. Description D ate Signature Typed or Printed Name License # Date PROJECT NUMBER DRAWN BY CHECKED BY ORIGINAL ISSUE: REVISIONS: KEY PLANNOT FOR CONSTRUCTIONI hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed professional engineer under the laws of the State of Minnesota E0.4P ELECTRICAL SITE PHOTOMETRIC DETAILS 4452.0002 MBS JJA 02/18/22 Blake Station Site B Blake Station Site B Hopkins, MN LUA Submittal 02/18/2022 NO SCALE FIXTURE TYPE W31 NO SCALE FIXTURE TYPE W42 NO SCALE FIXTURE TYPE W53 No. Description D ate