Loading...
VII. 1. 2022-13 Knollwood North Concept Plan Review October 25, 2022 Planning Application 2022-13 Knollwood Towers North Concept Plan Review Proposed Action As a concept review, this application does not require formal action by the Planning & Zoning Commission or City Council. Rather, the applicant requests feedback on the proposal so they can work toward preparing a future, formal submittal. Any comments provided by the City Council or Planning & Zoning Commission shall be for guidance only and shall not be considered binding upon the City regarding any future, formal application. Overview The applicant, Ben Delwiche with Kaas Wilson Architects, on behalf of Hopkins Apartments LLC the property owner, requests concept plan review for the Knollwood Towers North development. The subject property is located at the southwest corner of Blake Road and Lake Street. The applicant’s plans call for a seven-story, 139-unit building. The proposed building would be constructed in the location of two existing structured parking buildings. The proposal includes construction of a new shared parking structure. The site is currently guided Activity Center by the 2040 Comprehensive Plan and zoned RX-TOD, Residential-Office Mix Transit-Oriented District (TOD) Center. Primary Issues to Consider • Background • Public Comment • Zoning and Land Use Review • Potential Review Process Supporting Documents • Applicant’s Narrative, Plans, & Elevations • Zoning Review • Public Comments and Neighborhood Meeting Summary _____________________ Ryan Krzos, AICP City Planner Financial Impact: $ N/A Budgeted: Y/N ____ Source: _____________ Related Documents (CIP, ERP, etc.): _________________________________________ Notes: Knollwood Towers North - Concept Plan Review Page 2 BACKGROUND Knollwood Towers East, a six-story 129-unit, multi-family apartment building was originally constructed in 1968. Knollwood Towers West, a seven-story 187-unit multi-family apartment building was constructed in 1970. The 5.41 acre parcels comprising Knollwood Towers also contains two structured parking buildings (containing 206 and 128 stalls respectively) and associated surface parking areas with 106 total stalls – totaling 440 stalls or 1.39 per existing residential unit. Both of these existing parking structures are beyond their useful life. The applicant, on behalf of the current owner, has now come forward with a concept plan for development of a seven-story, 139-unit, multi-family apartment building in the location of the parking structures. A five-story, 365-stall structured parking building would also be constructed. With 46 existing surface stalls, 25 new surface stalls, and 137 stalls within the new building; a total of 573 parking stalls are proposed or 1.26 per residential unit. PUBLIC COMMENT As a concept plan review, no public hearing is required. However, the City did require the applicant to hold a neighborhood meeting to gather feedback from the community. The meeting was held on October 20th at the Cambridge Towers Community Room. The applicant mailed invitations to property owners and residents within 500 feet of the subject property (the same notification distance required of a typical public hearing). A summary of the neighborhood meeting is included as an attachment. Signage informing the community of a development proposal was displayed on the site. The City received one email message regarding the concept plans, which is also attached. ZONING AND LAND USE REVIEW The 2040 Comprehensive Plan Update – Cultivate Hopkins guides this property as Activity Center. According to the Comprehensive Plan, Activity Centers surround and support the planned Blake Road and Shady Oak light rail stations along the Southwest LRT Green Line Extension. These areas will include moderate to high density mixed use development designed to complement and enhance the existing development pattern in these areas and support the public investment in transit. The Activity Center areas are expected to experience significant reinvestment and redevelopment to absorb a substantial portion of the city’s anticipated future growth. Development in the Activity Center areas is expected to be medium to larger scale neighborhood and regional uses. Overall, densities in the Activity Center category will range from 20-60 units per acre; however, densities within ¼ mile of an LRT station platform must range between 75-150 units per acre within. The subject site is within ¼ mile of the Blake Road LRT Station. Inclusive of the two existing residential buildings, residential density would equate to 84.1 units per acre (455 total proposed and existing units within a total area of 5.41 acres). Accordingly, the proposal would bring the existing site more in-line with the residential density envisioned by the Comprehensive Plan. A detailed assessment of the proposed concept plans against the provisions of the Zoning Code is provided as an attachment. While there are a number of issues identified that are expected to be addressed as the plans get further refined, a summary of key items is provided below: • Lack of primary pedestrian entry along Blake Road. • Excess setback from Blake Road. • Compliance with building design requirements that ensure visual variety in the treatment of Knollwood Towers North - Concept Plan Review Page 3 facades along longer street-facing portions of the building. • Missing definition along parapet roof by way of shadow lines. • Lack of a second vertical division with shadow line along Lake St façade. • Application of more than one major façade material within building façade segments 60-foot or larger. Additionally, the applicant will need to verify that the major materials proposed would qualify as such. • Second story balconies are projecting and not integrated into the building’s architecture. • Compliance with parking structure design requirements. • Potential compliance with requirements of large-scale Planned Unit Developments as further discussed below. Planned Unit Development. The Zoning Code states that property owners must apply for Large- Scale Planned Unit Development overlay zoning whenever a site, three (3) acres or larger, is developed with multiple buildings, or if a subdivision is involved. Due to the configuration of the site, the proposed concept would necessitate the owner to either pursue approval under two scenarios: 1) Combining the two existing parcels into one resulting in multiple buildings on the lot. Since the existing parcels when combined are over three acres, the requirement for the Large-scale Planned Unit Development form of approval would apply under this scenario. 2) The two existing parcels are re-subdivided to create a new parcel for the proposed North building, with separate parcels for the existing East and West buildings respectively. Staff is interpreting this scenario as not meeting the threshold for a required Large-scale Planned Unit Development, so long as the resulting parcel is less than three acres. It should be noted that the applicant could pursue an optional Small-scale Planned Unit Development in this scenario. Alternatively, under this scenario the applicant could request a straight zoning approval, by way of site plan review, provided all of the zoning provisions are adhered to. Large-scale Planned Unit Developments are intended to promote master-planned development of large parcels with a system of streets, blocks, and open spaces, and a mix of zones to create new, walkable neighborhoods. Accordingly, the requirements for a Large-scale Planned Unit Development, which are detailed in Section 102-440(f), would include a required mix of zones, a compact layout of blocks and new streets, further refined pedestrian oriented features, and provision of civic spaces within 10% of the project. The Large-scale Planned Unit Development process would also require the applicant to contemplate and plan for how abutting parcels that are vacant or anticipated to be redeveloped within 10 years would be incorporated in the development as it relates to such items as access, street layout and mixing of uses. Staff will continue to work with the owner to better understand the constraints in order to identify the proper avenue of review. The purpose of any Planned Unit Development is to provide a cohesive development by way of allowing flexibility from traditional development standards in return for a higher quality development. Typically, the City looks for a developer to exceed other zoning standards, building code requirements or meet other goals of the Comprehensive Plan. In exchange for the flexibility offered by the Planned Unit Development process, the applicant is expected to detail how they Knollwood Towers North - Concept Plan Review Page 4 intend to provide a higher quality development or meet other City goals. The typical list of items the City considers when evaluating the use of a Planned Unit Development for this site includes, but is not limited to, the items listed below: • Enhanced architectural design and building materials • Natural resource protection and storm water management • Pedestrian and bicycle facilities in excess of minimums • Affordable housing • Enhanced sustainability or livability elements • Energy conservation and renewable energy • Open space preservation • Enhanced landscaping, streetscape, public art, or buffering POTENTIAL REVIEW PROCESS Based on the applicant’s concept plan, staff anticipates this project will need the approvals listed below. The applicant should use feedback from the Planning & Zoning Commission and City Council to prepare these applications: • Planned Unit Development accompanied by execution of a Planned Unit Development Agreement (as described above). • Site Plan Review is necessary under the re-subdivision scenario provided there are no requested deviations from the Zoning Code. • Lot Combination or Subdivision approval. As proposed by the concept plan, this process may not necessarily require additional review by the Planning & Zoning Commission or approval by the City Council. • Approvals from the Minnehaha Creek Watershed District. ENGINEERING COMMENTS The Engineering and Public Works department has reviewed the applicant’s concept plan and offered the following comments: • A traffic study will need to be completed to determine any impacts the development will have to adjacent streets and the transportation network. There are other planned developments adjacent to this site and the study should take into account the anticipated impacts from those in the analysis. • A review of the City’s sewer capacity in the vicinity and water model will need to be completed. There are other planned developments adjacent to this site and the review should take into account the anticipated impacts from those in the analysis. • The site is within the Minnehaha Creek Watershed District and the applicant will need to obtain a storm water permit from the District. RECOMMENDATION As a concept review, this application does not require formal action by the Planning & Zoning Commission; however, the Commission should discuss the proposal, particularly as it relates to the flexibilities and offsets for a potential PUD process, so they can work toward preparing a future, formal submittal. kaas wilson architects Knollwood AptsCOVER 0.0 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 Knollwood Apts 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 #21048 CONTENTS COVER 0.0 PROJECT SUMMARY 0.1 PROJECT DATA 0.2 SITE PHOTOS - SITE CONTEXT 0.3 ADJACENT BUILDINGS 0.4 SITE PLAN - EXISTING 1.0 SITE PLAN - PROPOSED 1.1 FLOOR PLAN - LEVEL -1 3.0 FLOOR PLAN - LEVEL 1 3.1 FLOOR PLAN - LEVEL 2 3.2 FLOOR PLAN - TYP. HOUSING LEVEL 3.3 FLOOR PLAN - LEVEL 7 3.4 BUILDING SECTION 4.0 CONCEPTUAL RENDERING 5.0 CONCEPTUAL RENDERING 5.1 CONCEPTUAL RENDERING 5.2 EXTERIOR ELEVATIONS 6.0 EXTERIOR ELEVATIONS 6.1 RAMP IMAGES 7.0 Diagramatic View Looking Southwest KNOLLWOOD EAST KNOLLWOOD WEST KNOLLWOOD NORTH L A K E S T R E E TBLAKE STREET Diagramatic View Looking Northeast KNOLLWOOD NORTH RAMP KNOLLWOOD EAST KNOLLWOOD WEST LAK E S T R E ET BLAKE STREET CONCEPTUAL RENDERING - NORTHEAST (BLAKE RD & LAKE ST) PROJECT TEAM DEVELOPMENT IPG Living 18006 Sky Park Circle Irvine, CA 92614 Julie Rodriguez: (714) 438-9191 ARCHITECT Kaas Wilson Architects 1301American Blvd E, Suite 100 Bloomington, MN 55425 (612) 879-6000 PROJECT NARRATIVE LOCATION 1010 Lake St NE. Hopkins, MN 55343 Currently comprised of: 187 unit Knollwood West with 46 surface stalls and 206 covered stalls 129 unit Knollwood East with 60 surface stalls and 128 covered stalls 316 units, 440 stalls. 139 unit Knollwood North -not built both existing garages beyond useful life repairs can only be temporary. goal: Feb 2023 Knollwood east Retrofitted. March 2023. West Ramp removed, as well as pool building for KW. new ramp built that will house 368 stalls + 32 stalls of Knollwood North Temp Street Parking will be needed for short term agreement with city. Ramp Projected Opening 4th of July 2023. Knollwood East Ramp demolished Potential for Ground Break of Knollwood North Aug 15, 2023-opening Oct. 2024. ZONING RX-TOD with a complex site such as this some variance may be expected however RX-TOD embraces density high quality materials and resident amenities are expected. there will be expectations that amenities be maintained for Knollwood West and East, and some level of affordability be maintained for K.W and K.E. Recommend Storage and Maintenance areas lost in KW will be replaced under new Ramp at Northwest quadrant. CONSTRUCTION PRE-RAMP RENOVATION Knollwood West (K.W. ) will lose storage, maintenance and trash Langerman can build temp trash enclosure during the 4 months of ramp construction maintenance can be moved to Cambridge which has an open maintence space there is a maintence space in the KW footprint that should be renovated to fitness/community once the ramp is built. $750,000 RAMP COST Langermand General Taracon Precast of Fargo, who will build and install all precast elements including stairs, and cabling, and stairs, joint caulking 30000-footings Langerman sub 30000-curbs at all levels 5000-mis rails in stairs and snow gates 7000-drivable surface, maintained yearly 8000-glazing at stairs 22000-plumbing drains each floor misc hose bibs 26000-lighting, low volt security Estimated cost $8,000,000 HOUSING COST 139 x $200k/unit=28,000,000 MISC SITE COSTS $500,000 CIVIL ENGINEER Civil Site Group 5000 Glenwood Ave Golden Valley, MN 55422 (612) 615-0060 STRUCTURAL ENGINEER BKBM 6120 Earle Brown Drive, Suite 700 Minneapolis, MN 55430 (763) 843-0420 kaas wilson architects Knollwood AptsPROJECT SUMMARY 0.1 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1" = 100'-0"1 Existing Site Location Aerial kaas wilson architects Knollwood AptsPROJECT DATA 0.2 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 UNIT MIX - GROSS AREA Name Count Unit Gross Area Total Area %Main Floor 0 BR Alcove) Unit 0-2 2 502 ft² 1,003 ft² 1.4% Unit 0-3 5 597 ft² 2,986 ft² 3.6% 7 3,989 ft² 5.0% 1BR Unit 1-3 65 747 ft² 48,533 ft² 46.8% Unit 1-4 5 728 ft² 3,640 ft² 3.6% Unit 1-8 1 724 ft² 724 ft² 0.7% Unit 1-9 1 780 ft² 780 ft² 0.7% Unit 1-10 1 672 ft² 672 ft² 0.7% 73 54,351 ft² 52.5% 1BR+DEN Unit 1.5-1 5 981 ft² 4,907 ft² 3.6% 5 4,907 ft² 3.6% 2BR Unit 2-2 3 1,222 ft² 3,665 ft² 2.2% Unit 2-2B 1 1,165 ft² 1,165 ft² 0.7% Unit 2-3 10 1,283 ft² 12,829 ft² 7.2% Unit 2-4 4 1,145 ft² 4,579 ft² 2.9% Unit 2-6 15 1,117 ft² 16,758 ft² 10.8% Unit 2-8 10 1,003 ft² 10,031 ft² 7.2% Unit 2-9 1 1,213 ft² 1,213 ft² 0.7% 44 50,241 ft² 31.7% 3BR Unit 3-0 10 1,591 ft² 15,913 ft² 7.2% 10 15,913 ft² 7.2% Grand total 139 129,401 ft² 100.0% GROSS AREA - TOTAL Level Area Level 7 25,289 ft² Level 6 25,277 ft² Level 5 25,277 ft² Level 4 25,277 ft² Level 3 25,277 ft² Level 2 22,239 ft² Level 1 22,347 ft² Level -1 33,977 ft² Grand total 204,960 ft² POST-TENSION TOTAL: 78,663 FT2 WOOD-FRAMED TOTAL: 126,302 FT2 EXISTING SITE PARKING (316 TOTAL UNITS): Surface Stalls: 106 Covered Stalls (West): 206 Covered Stalls (East): 128 Total Stalls: 440 (1.39 STALLS/UNIT) PROPOSED SITE PARKING (455 TOTAL UNITS): Surface Stalls: 71 Ramp Stalls: 365 Apartment Garage Stalls: 137 Total Stalls: 573 (1.26 STALLS/UNIT) Knollwood West Minneapolis Skyline view Multi-Family Housing Development Site Public Park Public Park Light Rail Station - Coming 2023 Knollwood East Knollwood West Minnehaha Creek 2 story parking SITE AMENITIES: - Light rail station coming 2023 - Shoppes at Knollwood (formerly Knollwood Mall) in walking distance - 2 public parks border the property - Minneapolis skyline views from site (above 3 stories) - Minnehaha Creek adjacent to property - Neighboring property under development Knollwood West parking garage from Lake Street Knollwood West towers from Lake Street - largest trees planted near building kaas wilson architects Knollwood AptsSITE PHOTOS - SITE CONTEXT 0.3 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 kaas wilson architects Knollwood AptsADJACENT BUILDINGS 0.4 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 KNOLLWOOD TOWERS EAST KNOLLWOOD TOWERS WEST LAKE STREET NE N89°27'22"W 465.22N1°02'48"E 380.64S89°16'40"E 461.40 N0°28'13"E 379.191 1 2 1 VICINITY MAP NOTES CORRESPONDING TO SCHEDULE B - 2 PROPERTY DESCRIPTION TABLE "A" OPTIONAL ITEMS GENERAL NOTES CERTIFICATION 1 2 STATEMENT OF POSSIBLE ENCROACHMENTS SUBJECT PROPERY LEGEND LAKE STREET NE BLAKE ROAD N.S89°23'28"E 198.22S0°28'13"W 467.41N89°16'40"W 166.53 L=218.18R=5685.58Δ=2°11'55"CHB=N01°36'05"WCH=218.17N2°42'03"W 239.43N 4 5 ° 5 3 ' 4 9 " W 14 . 5 9 NOTES CORRESPONDING TO SCHEDULE B - 2 PROPERTY DESCRIPTION TABLE "A" OPTIONAL ITEMS GENERAL NOTES CERTIFICATION 1 2 STATEMENT OF POSSIBLE ENCROACHMENTS VICINITY MAP LEGEND SUBJECT PROPERY 3 two story parkingseven story tower KNOLLWOOD WEST seven story tower two story link two story parking KNOLLWOOD EAST seven story tower seven story tower PUBLIC PARK EXISTING SITE PARKING: Surface Stalls: 138 Covered Stalls (West): 103 x 2= 206 Covered Stalls (East): 128 Total: 472 472 - 71 Surface = 401 Stalls + 100 Ramp =501 Ramp 46 stalls 103 + 103 = 206 64 + 64 = 128 8 20 temp stalls 1 2 3 4 5 6 7 8 kaas wilson architects Knollwood AptsSITE PLAN - EXISTING 1.0 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1" = 80'-0"1 Site Plan EXISTING Knollwood Towers WestKnollwood Towers East7 Stories / 139 Units FFE 918 PARKING RAMP: 5 STORIES 365 STALLS Commons Patio Garage Entrance (Level -1)Retaining Wall Main Entrance Garage Entrance (Level 1)25 STALLS 37 STALLS No apartment windows on this facade No apartment windows on this facade 71'-0"24'-0"31'-0" 13'-0" Tot Lot Grill Station & Outdoor Seating Lawn Games 14 9 14 Surface Parking 46 Stalls 9 kaas wilson architects Knollwood AptsSITE PLAN - PROPOSED 1.1 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1" = 80'-0"1 SD SITE PLAN UP 33,060 ft² Garage SLOPE DOWN 1 4.0 175 ft² Maint. Office 6.0 1 6.05 200 ft² Stair 226 ft² Stair 6.0 4 6.0 2 kaas wilson architects Knollwood AptsFLOOR PLAN - LEVEL -1 3.0 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1/32" = 1'-0"1 Level -1 UP 13,362 ft² Garage 1,228 ft² Lobby / Lounge 1,271 ft² Fitness / Yoga 1,365 ft² Game Room 718 ft² Leasing / Mail / Parcel 446 ft² Bicycles 1,362 ft² Community Room 390 ft² Restrooms 1 4.0 BOCCI & BAG TOSS DECK DN UP 6.0 1 6.05 279 ft² Stair 6.1 2 1 DN 226 ft² Stair 6.0 4 6.0 2 kaas wilson architects Knollwood AptsFLOOR PLAN - LEVEL 1 3.1 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1/32" = 1'-0"1 Level 1 1 4.0 1,222 ft² Unit 2-2 1,222 ft² Unit 2-2 6.0 1 6.05 1,003 ft² Unit 2-8 1,003 ft² Unit 2-8 1,003 ft² Unit 2-8 1,003 ft² Unit 2-8 1,213 ft² Unit 2-9 279 ft² Stair 724 ft² Unit 1-8 6.1 2 1 1,003 ft² Unit 2-8 1,003 ft² Unit 2-8 502 ft² Unit 0-2 672 ft² Unit 1-10 502 ft² Unit 0-2 780 ft² Unit 1-9 1,222 ft² Unit 2-2 1,003 ft² Unit 2-8 1,003 ft² Unit 2-8 279 ft² Stair 6.0 4 6.0 2 1,003 ft² Unit 2-8 1,003 ft² Unit 2-8 1,165 ft² Unit 2-2B kaas wilson architects Knollwood AptsFLOOR PLAN - LEVEL 2 3.2 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1/32" = 1'-0"1 Level 2 1 4.0 981 ft² Unit 1.5-1 6.0 1 6.05 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 1,117 ft² Unit 2-6 747 ft² Unit 1-3 1,117 ft² Unit 2-6 728 ft² Unit 1-4 6.1 2 1 1,283 ft² Unit 2-3 597 ft² Unit 0-3 1,283 ft² Unit 2-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 1,145 ft² Unit 2-4 280 ft² Stair 1,117 ft² Unit 2-6 1,591 ft² Unit 3-0 1,591 ft² Unit 3-0 333 ft² Stair 6.0 4 6.0 2 kaas wilson architects Knollwood AptsFLOOR PLAN - TYP. HOUSING LEVEL 3.3 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1/32" = 1'-0"1 Level 6 1 4.0 697 ft² Rooftop Deck 981 ft² Unit 1.5-1 6.0 1 6.05 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 1,117 ft² Unit 2-6 747 ft² Unit 1-3 1,117 ft² Unit 2-6 728 ft² Unit 1-4 280 ft² Stair 376 ft² Sky Lounge 6.1 2 1 1,283 ft² Unit 2-3 597 ft² Unit 0-3 1,283 ft² Unit 2-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 747 ft² Unit 1-3 1,117 ft² Unit 2-6 1,591 ft² Unit 3-0 1,591 ft² Unit 3-0 333 ft² Stair 6.0 4 6.0 2 kaas wilson architects Knollwood AptsFLOOR PLAN - LEVEL 7 3.4 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1/32" = 1'-0"1 Level 7 Level 1 917'-0" Level 3 938'-10" Level -1 905'-8" Level 4 949'-5 7/8" Level 5 960'-1 3/4" Truss Brg. 991'-4 5/8" Level 2 927'-8" Level 6 970'-9 5/8"11'-2"10'-7 7/8"10'-7 7/8"11'-4"10'-7 7/8"Level 7 981'-5 1/2"9'-11 1/8"10'-7 7/8"10'-8"EXPOSED GARAGE6'-0"TYPE IIIA LIMIT85'-0"8"1'-2"APPROX. AVG GRADE PLANETYPE IA33'-2"10'-0"10'-0"9'-0"LOWEST LEVEL OF FIRE ACCESS ~908 3HR SLAB (14")8'-0"9'-0"SOFFIT1'-0"SOFFIT2'-0"2'-0"75'-0"18'-10"GARAGE CONTINUES BEYOND kaas wilson architects Knollwood AptsBUILDING SECTION 4.0 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 3/32" = 1'-0"1 Building Section Looking North kaas wilson architects Knollwood AptsCONCEPTUAL RENDERING 5.0 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 CONCEPTUAL RENDERING - NORTHEAST VIEW (BLAKE RD & LAKE ST) kaas wilson architects Knollwood AptsCONCEPTUAL RENDERING 5.1 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 CONCEPTUAL RENDERING - EAST VIEW (BLAKE RD) kaas wilson architects Knollwood AptsCONCEPTUAL RENDERING 5.2 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 CONCEPTUAL RENDERING - NORTH VIEW (LAKE ST) BRICK FIBER CEMENT PANEL ROOFTOP DECK METAL CLADDING STUCCO Level 1 917'-0" Level 3 938'-10" Level -1 905'-8" Level 4 949'-5 7/8" Level 5 960'-1 3/4" Truss Brg. 991'-4 5/8" Level 2 927'-8" Level 6 970'-9 5/8" Level 7 981'-5 1/2" FIBER CEMENT PANEL METAL CLADDING BRICK 6'-0"STUCCO Level 1 917'-0" Level 3 938'-10" Level -1 905'-8" Level 4 949'-5 7/8" Level 5 960'-1 3/4" Truss Brg. 991'-4 5/8" Level 2 927'-8" Level 6 970'-9 5/8" Level 7 981'-5 1/2" kaas wilson architects Knollwood AptsEXTERIOR ELEVATIONS 6.0 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1" = 30'-0"1 NORTH ELEVATION 1" = 30'-0"5 EAST ELEVATION 1" = 30'-0"2 WEST ELEVATION 1 1" = 30'-0"4 SOUTH ELEVATION 2 EXTERIOR MATERIAL PERCENTAGES NORTH FACADE (LAKE ST) MAJOR MATERIALS (BRICK, CMU, STUCCO) = 68% MINOR MATERIALS (CFB, METAL PANEL) = 32% EAST FACADE (BLAKE RD) MAJOR MATERIALS (BRICK, CMU, STUCCO) = 73% MINOR MATERIALS (CFB, METAL PANEL) = 27% Level 1 917'-0" Level 3 938'-10" Level -1 905'-8" Level 4 949'-5 7/8" Level 5 960'-1 3/4" Truss Brg. 991'-4 5/8" Level 2 927'-8" Level 6 970'-9 5/8" Level 7 981'-5 1/2" kaas wilson architects Knollwood AptsEXTERIOR ELEVATIONS 6.1 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 1" = 30'-0"1 SOUTH ELEVATION 1 1" = 30'-0"2 WEST ELEVATION 2 kaas wilson architects Knollwood AptsRAMP IMAGES 7.0 1010 Lake Street Northeast, Hopkins, MN 55343 09/23/2022 21048 Taracon Precaster Ramp-Fargo -300 32nd Ave W, West Fargo, ND 58078 is a carbon copy of what KWA Recommends in Hopkins From:Steve Steinman To:Ryan Krzos Cc:Jan Youngquist; Mike Mornson Subject:[EXTERNAL] Meeting tommorrow night..proposed developement ...Knollwood Towers West, East Date:Thursday, October 20, 2022 2:05:24 AM I understand there is a meeting tomorrow night regarding a proposed development. If someone can not attend will there be a way to watch it at a later date? It is at Cambridge Towers if I am correct. This email is to make clear that I feel there is a problem with the current management company. I want to make sure you are aware of the History of the Management company that is now Managing the two properties, Knollwood Towers West and East. They have had shootings in both buildings since they have been the owners. They are very difficult to deal with and often do not return calls or emails examples of what have taken place are: Water on the floor from the laundry room to the hall yesterday. Carpets that are dirty on many of the floors. Smoke smell in the building that is non smoking, smoke smell even in the hall next to the office during business hours. False advertising, maybe not illegal but they sign letters with we are here to help..not my experience..can't often get a hold of them. Last week the lobby was full of tenants who had received letters on their doors. I saw a couple of the letters, ( I believe all were but I did not see them all) letters of intent to evict. Some of the tenants told me they were sure it was a mistake and at least one I know for sure was not correct. Some people waited for hours to see the office. I do not know if what they did was illegal but it was disgusting to handle the situation the way they did. I hope someone from the city can ask people about this if someone from the city is at the meeting. They charge now for garbage but refuse to lock the garbage room door so anyone can just leave what they want in there and we all get charged. There has been a problem with how they bill us for the Utilities, incorrect bills hoping it will get straightened out but not seen it yet. No breakdown on how they come up with the bills and I think it seems unfair, but maybe not illegal..not sure..the billing is vague and not detailed. The building is not secure, people have been seen entering through the garbage room for some time now. It has been left wide open in the last week several times. I have been told by others that it used to have a lock on it. I never saw it left open till this managemant company took over. The East building requires the trash company to use a key to get in already, yet the management company has not been able to figure out a way to simply put a lock on the door and give the trash company a key. No formal communication has been sent to us regarding anything they are doing about the door. This door has not been lockable for some time now. I smelled paint in the stairwell in the last week, .not sure why.....people entering the building and getting high? People knock on doors and attempt to open door making me think they are possibly not from this building. Packages are stolen and opened, the management says its not just here, but they do nothing to help...no closet or room...just in the open for everyone to see. Smoke alarms are beeping on more then one floor in the West building....they had a major fire in the West building this year...some balconies are just full of junk. There is more but I think you can understand that there is a problem here. I hope if the management company makes any promises or says they will be doing something the city takes into account the history of the buildings since they took over. They hired security that is here, I am not sure when, and the place is still scary. I do not feel safe, and having doors propped open just makes it worse. Also, the management company does not provide upper level contacts, it is very difficult to reach anyone above the building office so the office can do what it wants. Thank you, To be transparent my name is not Steve but I do live in Knollwood Towers West. I am afraid to use my real name, the management company has convinced me they are not here for us. Tommorrow evening is a great time for someone to hear first hand what the experience of living in Knollwood Towers East and West is like. Thank you, ZONING REVIEW: KNOLLWOOD TOWERS NORTH INFILL DEVELOPMENT Review Date: October 25, 2022 PROJECT DECRIPTION: Infill development of a lot containing multiple existing structures: Two residential apartment buildings two parking structures. Development of a new L-shaped mixed-use building with basement and first level parking, interior common amenity spaces, and 139 apartments. BASE ZONE: RX-TOD PROPOSED USE: Multi Family BUILDING TYPES ALLOWED: General Building, Row Building COMPREHENSIVE PLAN DESIGNATION: Activity Center BUILDING TYPE SELECTED: General Building EXISTING USE: Multi-Family, Parking Garage LARGE PUD REQUIRED? Yes/No DEADLINE FOR ACTION N/A ZONING MAP Review Key  Meets or exceeds regulation N/A Regulation does not apply  Does not meet regulation Cond. Met per conditions ? More Information Needed PUD PUD/Variance Deviation ARTICLE 3 MIXED-USE ZONES Section of Code Regulation REVIEW NOTES 102-350 REGULATIONS APPLICABLE TO ALL BUILDING TYPES  102-350(a) PERMANENT STRUCTURES Proposed structures are permanent. PUD 102-350(b) ONE BUILDING PER LOT Concept shows there may be more than one principal building per lot, which would be require a Large-scale PUD.  102-350(c) TREATMENT OF YARDS Surface parking is to rear of building per building type regulations Street yard areas appear to be planned for people and landscaping. ? 102-350(d) TRASH, RECYCLING, REFUSE LOCATIONS Location of utilitarian items to be identified as plans are refined  102-350(e) FRONT STREETS Blake Road is the designated front street abutting this lot. ? 102-350(f) MINIMUM PEDESTRIAN AREA There appears to be +/- 8 ft between the curb and the lot line on the Lake St NE side. Four feet of additional streetscape space need to be provided, and setbacks are to be measured from 12 ft of the back of the curb. 102-380 GENERAL BUILDING TYPE REGULATIONS (RX-TOD Zone) Section of Code Regulation REVIEW NOTES 102-380(d) BUILDING LOCATION PUD 120-380(d) MULTIPLE PRINCIPAL BUILDINGS Allowed; Given Size of Project a PUD would be required if within one parcel. ? 120-380(d) FRONT STREETWALL 80% min.; Additional information on the lot line configuration is needed.  120-380(d) FRONT STREET SETBACK 7.5 ft. min, 15 ft. max.; Proposed building is setback 20-24 ft from the Blake Road Property line ? 120-380(d) NON-FRONT STREET SETBACK (Lake Street Side) 5 ft. min., 15 ft. max; Additional information on the location of the curb line in relation to the building is needed. ? 120-380(d) SIDE SETBACK 5 ft. min. Additional information on the lot line configuration is needed.  120-380(d) REAR SETBACK 20 ft. min. ? 120-380(d) IMPERVIOUS SITE COVERAGE 80% max. Additional information on the lot line configuration is needed. ? 120-380(d) ADDITIONAL SEMI-PERVIOUS COVERAGE +15% - In addition to the 80% hardcover, 15% of the site may be semi-pervious, i.e. green roof, porous pavement, etc. 102-380(e) PARKING & ACCESSORY STRUCTURES  120-380(e) PARKING & DRIVEWAY ACCESS LOCATION Required off alley or non-front street; proposed driveway off of Lake St NE.  ? 120-380(e) DRIVEWAY SIZE & NUMBER Depicted driveway width (+/- 24 ft.) would exceed 22 ft maximum Max. 1 access per development per street. One new access is proposed. Compliance depends on how/if the property is divided.  120-380(e) ATTACHED GARAGE SETBACK Required 20 ft. min. behind front facade in rear of building; First floor structured parking is positioned ~64 ft to the rear of the Blake Road front façade.  120-380(e) ATTACHED GARAGE DOOR LOCATION Proposed on interior side as is required  120-380(e) SURFACE PARKING Proposed in Rear Yard as is required.  120-380(e) ACCESSORY STRUCTURES Parking Structure is allowed and is proposed 120-380 (f) HEIGHT  120-380(f) HEIGHT 2 stories min, 10 stories max; Seven (7) Stories proposed  120-380(f) ALL STORIES HEIGHT 9 ft. min., 14 ft. max.; All stories shown as between 9 ft and 11 ft in height 120-380 (g) ROOFS  120-380(g) ROOF TYPES Flat, parapet, pitched allowed; appears to be proposed as parapet  120-380(g) TOWER Allowed, none proposed 120-380 (h) STREET FACADES ? 120-380(h) TRANSPARENCY: FRONT FACADES 20% min; Transparency not quantified. ? 120-380(h) TRANSPARENCY: NON-FRONT FACADES 18% min; Transparency not quantified.  120-380(h) BUILDING ENTRANCES LOCATION One per every 120 ft. on front façade; Blake Street side requires a minimum of one entrance.  120-380(h) ENTRANCE TRANSITION TYPE A Stoop entrance type is Required. See 102-730 (c) ? 120-380(h) GROUND STORY ELEVATION Between 18 in. and 30 in. above grade or between 30 in. and 4 ft. with a visible basement, except in floodplain locations.  120-380(h) HORIZONTAL DIVISIONS WITH SHADOW LINES Horizontal shadow lines to run a min. 80% of length of facade. One division is required within 3 ft. of the top of any story between the basement and 3rd  120-380(h) VERTICAL DIVISIONS WITH SHADOW LINES One vertical division is required per every 120 ft. of street façade. Two vertical divisions are needed along Lake Street Façade, only one provided. 102-380 (i) SUPPLEMENTAL GENERAL BUILDING REGULATIONS   120-380(i)(1) FRONT STREETWALL EXCEPTIONS No street facing courtyard proposed Maximum setback may be expanded up to 20 feet for a maximum of 20% of the facade to allow for permanent outdoor seating or outdoor dining area; more than 20% of the façade exceeds the Blake Road maximum setback. N/A 120-380(i)(2) THROUGH-LOTS Subject site is not a through lot. N/A 120-380(i)(3) STORY SETBACKS AT N OR NX N/A. No N or NX zoned property abuts the site. N/A 120-380(i)(4) VISIBLE BASEMENTS For basement levels located more than 3 ft. above grade, street facades must meet the transparency regulations. N/A 120-380(i)(5) ADDITIONAL STORY HEIGHT (IX-TOD & IX-S) N/A. Site is not zoned IX. ARTICLE 7 BUILDING DESIGN Section of Code Regulation REVIEW NOTES 102-720 (c) PARAPET ROOF TYPE ?   102-720(c)(1) PARAPET HEIGHT Minimum height is 1.5 feet with a maximum height of 6 feet A shadow line must be located within 2 feet of the top of the uppermost story. A shadow line must be located at the top of the parapet. See 102-16210 for definition of shadow line  102-720(c)(2) OCCUPIED BUILDING SPACE No portion of the parapet appears to include occupied building space. ? 102-720(c)(3) ROOFTOP APPURTENANCES Any rooftop appurtenances must be located towards the rear or interior of the parapet roof. Rooftop appurtenances should be located such that the parapet blocks their view from the sidewalk across the street. No rooftop equipment depicted. 102-730 (c) STOOP ENTRANCE TYPE ? 102-730(c)(1) STOOP SIZE A stoop is a small, open platform that may include a canopy or roof cantilevered off the building and may or may not be elevated above the sidewalk. Stoops must be a minimum of 4 feet wide and 3 feet deep ? 102-730(c)(2) RAMPS Where feasible, ramps should be incorporated at the principal building entrance and designed as an integrated part of the stoop, with rails matching any provided on steps. 102-740 FAÇADE MATERIALS ? 102-740(b) MAJOR STREET FACADE MATERIALS Allowed major façade materials, listed in Table 7-1 for General Building Type in the RX-TOD Zone: Full Dimension brick, architectural Concrete Masonry Units, Stone, 2-3 layer cement-based stucco. ? 102-740(b)(1) STREET AND OTHER FRONT FACADES Major materials must be applied to a minimum of 65% of all street or other front facades, not including window and door areas. Blake Rd (east) façade: 73% as Brick, CMU, Stucco Lake St (north) façade: 68% as Brick, CMU, Stucco Proposed brick would have to be full brick and not veneer. Proposed stucco must be traditionally-applied stucco and not synthetic or EFIS ? 102-740(b)(2) SIMPLICY OF FACADE MATERIALS A single major façade material must be used for each building façade segment, 60-foot or larger. Significant portions of both the Blake Road and Lake Street facades use multiple major materials – not clear if any single material would be at least 65% like it is with majority brick on the Lake/Blake corner. ? 102-740(b)(4) SIDE AND REAR FACADES When side yards between two buildings are a total of 5 or more feet in width, major materials must be applied along that side facade from the front of the building a distance equal to the width of the side yard, as measured perpendicularly between the two side facades. Major materials are indicated as proposed from the two side, but would need to meet simplicity rules above. N/A 102-740(b)(5) ORIGINAL FAÇADE MATERIALS Applicable to modifications of existing buildings with brick or stone facades. N/A.  102-740(c) MINOR STREET FACADE MATERIALS A maximum of 35% of each street or other front façade surface, not including window and door areas, may be composed of minor facade materials. Blake Rd (east) façade: 27% as Fiber Cement, Metal Panel Lake St (north) façade: 32% as Fiber Cement, Metal Panel  102-740(d) SIDE & REAR FACADE MATERIALS All interior side and rear (non-street) facades not located on a rail or trail line must be faced in a major facade material, a minor facade material, or a material as allowed in Table 7-3. Same material palette used on side and rear as the street facades. ? 102-740(f) APPROPRIATE GRADE OF MATERIALS All doors, windows, and hardware must be of commercial grade quality. ? 102-740(g)(1) CHANGES IN FACADE MATERIALS Changes in façade materials, whether major materials or minor materials, should occur mainly at concave corners or changes in facade planes.  102-740(g)(2) MATERIALS HIERARCHY A hierarchy of materials must be maintained on the building facade, where "heavier", articulated unit materials (brick, concrete masonry units, stone) are located at the base of the facade and "lighter", constant surface materials with fewer seams (stucco, panels) are located above those on the facade.  102-740(g)(3) SHADOW LINES ON SURFACES Shadow lines must delineate changes in materials with solid materials of a thickness that is greater than 1.5 inches, such as cast stone, masonry, or stone 102-750 FACADE ELEMENTS ? 102-750 (b) WINDOWS All windows, with the exception of ground story storefront systems and glass curtain wall systems, shall be recessed with the glass a minimum of 2 inches from the facade surface material or adjacent trim. This level of detail not provided, but appears to be met.  ? ?  A minimum of 70% of street façade windows must be vertically oriented. All windows appear vertically oriented Reflective glass and glass block are prohibited on street and other front facades. Assume reflective glass is not used A minimum of 70% of all street facade upper story windows must be operable. Ground story storefront glass and glass curtain wall systems are not required to be operable. This level of detail not provided. For masonry construction, the expression of lintels must be included above all windows and doors by a change in brick coursing or by a separate detail or element. No lintels depicted at windows and door in the brick areas. ? 102-750(c) AWNINGS & CANOPIES No awning or canopies shown ?  102-750(d) BALCONIES Balconies must be a minimum of 4 feet deep and 5 feet wide. A minimum of 50 percent of the perimeter of each balcony must abut an exterior wall of the building, partially enclosing the balcony. Second Story balconies do not appear to meet this standard. N/A 102-750(e) SHUTTERS Any shutters must meet size and material requirements. No shutters depicted N/A 102-750(f) SECURITY GRILLS & BARS Exterior security bars and grills are prohibited. Interior grills must be retractable and hidden when retracted. None shown ? 102-750(g) PRINCIPAL ENTRYWAY Principal entrances to the building must be clearly delineated through one or more design features in Section 102-750(g) N/A 102-750(h) ARCADE DESIGN No Arcade proposed ? 102-750(i)(2) GROUND STORY AT SLOPING FACADES FOR NON-STOREFRONTS Retaining walls shall not exceed 30 inches in height except along a maximum 8-foot section of frontage. Additional information on retaining walls needed.  102-750(j) BUILDING VARIETY buildings 90 feet in length or greater, as measured along any street or front facade, must treat that frontage in segments of 50 feet or less with the building variety standards in 102- 750 (j)(3). Both the Blake Road and Lake Street side exceed 90 ft.  102-750(k) ARTICULATION OF STORIES Window placement on street facades must be organized by stories per the transparency regulations. Windows are arranged by floor. Shadow lines can be used to delineate stories. N/A 102-750(l) VISTAS Vistas (an open space or a street terminating) are not present at this site.  102-750(m) GARAGE DOORS Requirements are applicable to garage doors included on any street facade. Garage doors proposed on non-street facades. 102-760 UTILITY EQUIPMENT ? 102-760(b) MECHANICAL EQUIPMENT IN BUILDING Mechanical equipment shall be located within the building, unless the applicant demonstrates that locating the equipment within the building would conflict with the equipment’s function. ? 102-760(c) ROOFTOP MECHANICAL EQUIPMENT Any rooftop mechanical equipment is to be screened or setback ? 102-760(d) MECHANICAL EQUIPMENT ON STREET FACADES Mechanical equipment and utility appurtenances shall not be located on a street facade unless the applicant demonstrates that locating the equipment in a different location would conflict with the equipment’s function. Any equipment or appurtenance approved on a facade shall be located consistent with the standards of this section. ? 102-760(e) MECHANICAL EQUIPMENT ON OTHER HORIZONTAL FACADES Mechanical equipment, such as electrical transformers and air conditioners, located on the ground, decks, or horizontal surfaces other than the roof shall be located consistent with the standards of this section. ARTICLE 8 LANDSCAPE & SITE DESIGN Section of Code Regulation REVIEW NOTES ? 102-810(b) VISIBILITY AT INTERSECTIONS A 30 ft by 30 ft vision triangle, free from walls, fences, plants, or trees in excess of 30 inches above the abutting curb line shall be provided. ? 102-820 LANDSCAPE INSTALLATION Notes to follow the specified landscape installation regulations required on submittal drawings. ? 102-830 LANDSCAPE MAINTENANCE The owner is responsible for the maintenance, repair, and replacement of all landscaping required by code ? 102-840 EXISTING TREES A survey of existing trees on the site is required. Significant and contributing trees Tree protection is required ? 102-850 GROUND VEGETATION All unpaved areas of any lot in any other zone must be covered by planting bed per 102-850 (b) or grass per 102- 850 (c) or a combination of planting bed and grass. ? 102-860 SITE TREES One medium or large tree is required per 3000 square feet of yard area. ? 102-870 STREETSCAPE DESIGN The requirements of this section apply to development of new streets and development on all lots with 200 feet or more of street frontage on existing streets or the City may assess a fee-in-lieu of streetscape for deposit in the city’s streetscape fund. ? 102-880 STREET SIDEWALKS Sidewalks or multi-use paths must be provided along all street frontages, located within the public right-of-way. ? 102-890 INTERNAL SITE SIDEWALKS Sidewalks must connect between all building entrances to all public sidewalks, including at least one connection to each street-frontage sidewalk abutting the site ? 102-8100 STREET TREES Each lot is required to have one tree for every 40 feet of street frontage with a minimum of one street tree per street frontage, and must be located between the curb and sidewalk, a minimum of 2 feet and a maximum of 10 feet off the back of curb ? 102-8110 FRONTAGE BUFFERS A frontage buffer is required when on-site vehicular parking, loading, outdoor storage, and/or other activities abut the street N/A 102-8120 SIDE & REAR BUFFERS A side and rear buffer is required along the side and rear lot lines where transitions between certain zones occur ? 102-8130 INTERIOR PARKING LOT LANDSCAPE All off-street surface parking lots with more than 10 spaces and/or more than one drive aisle must meet the interior parking lot landscape regulations. ? 102-8140 SCREENING OF REFUSE & UTILITY AREAS All dumpsters, loading areas, open storage, refuse areas, mechanical equipment, and utility appurtenances must be screened ? 102-8150 OUTDOOR LIGHTING No lighting found in drawings. ARTICLE 9 PARKING & MOBILITY Section of Code Regulation REVIEW NOTES  102-920 OFF-STREET PARKING – MOTOR VEHICULAR MINIMUMS & MAXIMUMS Minimum for Multi-family: 1.2 enclosed stalls per unit No Maximum. 1.26 stalls per unit provided. Proposed parking would be shared with two existing buildings. 316 Total new and existing unit. 573 Stalls provided (Surface Stalls: 71, Ramp Stalls: 365, Apartment Garage Stalls: 137) ? 102-920 OFF-STREET PARKING – BICYCLE MINIMUMS Minimum for Multi-family: 1.1 stalls per unit. With 90% as long-term. This would apply to the new units as the existing units pre-date the requirement. N/A 102-940 PARKING REDUCTIONS & CREDITS Applicant can pursue a reduction per with provision of affordable units or Alternative Compliance per Section 102- 940 (i). N/A 102-950 LOCATION OF OFF-STREET PARKING Except as otherwise expressly stated in this article, required off-street parking areas must be located on the same lot as the building or use they are required to serve.  ? 102-960 PARKING AREA LAYOUT & DESIGN Parking areas must be designed to allow vehicles to enter and exit a street and cross public sidewalks in a forward motion Parking stalls must be standard or compact ? 102-970 ELECTRIC VEHCILE SUPPLY EQUIPMENT Proposal includes residential off-street parking areas with 50 or More Parking Spaces. One Level 2 electric vehicle charging station plus at least one Level 1 or Level 2 electric vehicle charging station for a minimum of 10% of provided parking spaces. At least one of the electric vehicle charging stations provided must be accessible to a vehicle parked in an accessible parking space. An Additional 10% of the spaces must be EV-ready. ? 102-990 BICYCLE PARKING Short-term bicycle parking must be located on the subject lot, unless the city approves a proposal to allow private bicycle parking facilities to be located in the right-of-way. Long-term bicycle parking spaces must: − Be located with direct access by the bicycle rider, with no more than 50% of the required spaces requiring the use of stairs or elevators; − May not be located in dwelling units or on dwelling unit balconies; − Must protect the entire bicycle, its components and accessories against theft and inclement weather, including wind-driven rain and snow. − Must be designed to allow bicycles to be securely locked to a bicycle rack in: A bike storage room that is accessible only to authorized users and has at least 2 electrical outlets; or a bicycle locker with a separate access door for each bike; or an attended bike storage room. ARTICLE 6 ACCESSORY USES AND STRUCTURES (PARKING STRUCTURE) Section of Code Regulation REVIEW NOTES 102-690 PARKING STRUCTURES  102-690(c) LOCATION Accessory parking structures must be located in the rear yard and be screened from view of any primary street by the principal building. Parking structures on lots with multiple primary street frontages must be screened from view of all primary streets. Generally, the new and existing buildings screen the structure from view.  102-690(d) ADDITIONAL REGULATIONS Parking structures may not be located closer to any street or interior side lot line than the principal structure. Structure located to the rear of the primary buildings. The overall height of a parking structure must be at least one story lower than the tallest principal structure. Five- story parking structure is proposed. 102-750 (n) PARKING STRUCTURE FACADES ? 02-750 (n) PARKING STRUCTURE FACADES Parking structure facades visible from any street or abutting any pedestrianway or open space shall meet the following standards ? 102-750 (n)(1) MATERIALS Major and minor material requirements shall be met on all street and other front facades. An additional permitted minor material is stained, finished concrete ? 102-750 (n)(2) RAMPS AND SLOPES Ramps and slopes shall not be located on any front or street facades. ? 102-750 (n)(3) VERTICAL DIVISIONS Vertical divisions extending the full height of the structure are required every 30 feet to deemphasize the horizontal decks. Divisions shall be a minimum of 2 feet in width with a minimum projection of 2 inches. ? 102-750 (n)(4) BLANK WALL LIMITATION No rectangular area greater than 30 percent of any story’s facade, as measured from floor to floor, and no horizontal segment of a story’s facade greater than 15 feet in width may be solid wall without an opening. ? 102-750 (n)(5) ENTRY TOWER A pedestrian entrance directly into the parking structure from the street is required to be separate from the vehicular entrance and directly accessed from the sidewalk. The pedestrian entrance must meet the principal entryway regulations in 102-750 (g). Stairwells must be located inside a tower with windows at a transparency rate of 65%. ? 102-750 (n)(6) CAP The top story of the parking structure shall include a parapet or other roof type along the public way facades. ? 102-750 (n)(7) VEHICULAR ENTRANCES Driveways shall be no wider than 22 feet and the entrance and exit should be split by a median. Access shall be located on a non-front street, unless the lot does not abut a non- front street. No more than 2 access points shall be located on any one street, totaling no more than 24 feet of drives crossing sidewalk