Loading...
Application by SuperValu for CUP at 11th Ave SO. & 5th St.July 21, 1981 Case No: 81 -27 Applicant: Super Valu Location: llth Avenue South Fifth Street Request: Conditional Use Permit STAFF FINDINGS COMMENTS: Kerrigan Rafferty 1. The applicant is requesting a Conditional Use Permit to construct a 117,714 square foot refrigerated warehouse complex. The applicant received concept approval of the proposed project at a special meeting on July 14. The site is presently zoned I -1 Industrial. 2. The exterior treatment for the front of the proposed structure (south) is to be decorative concrete tan panels accented with dark brown aluminum trim. The east, west and north walls are to be white insulated metal panels. 3. 107,184 square feet of the proposed structure would be warehouse with 7530 square feet of office space. The applicant is also proposing a 3000 square foot mechanical room. This space was not shown on the plan submitted for concept review. The applicant has stated the proposed mechanical room will be located either as an addition on the west side of the proposed structure or within the overall warehouse complex itself. 4. The applicant is proposing to provide a narrow planted greenway along the southerly and westerly perimeter of the proposed site. A 20 foot planted bermed area shall be located on the southerly property line directly in front of the proposed structure. An 8' cyclone fence -shall surround the property on all sides, with wood slats inserted in the fencing on the south and west property lines. No internal landscaping is proposed. The landscape and fencing plan will be required to comply with 427.10 which states that on corner lots in all distrcits except B -2 and B -3, no structure or planting in excess of thirty (30) inches above the abutting curb line shall be permitted within a triangular area defined as follows: beginning at the intersection of the projected curb lines of two intersecting streets thence 30 feet along one curb line, thence diagonally to a point thirty feet from the point of beginning on the other curb line, thence to the point of beginning. 5. The Fire Marshal has reviewed the submitted plans and states that the following requirements would have to be complied with if the proposal is approved: a) entire structure to be sprinkled b) installation of a curbside Fire Department connection on the south property line in front of the proposed structure c) installation of a looped water system from Fifth Street South 3rd Street South, including the installation of 3 fire hydrants on the subject property (an alternate looped system could be installed provided it is approved by the Fire Marshal). 6. The applicant is proposing to provide 40' high light standards on both the south and east property lines. It is proposed that these lights will have no rear re- flector so as to confine all light produced to the subject parcel. A number of security lights will all be attached to the building. Case No: 81 -2 Super Valu Page 2 7. The drainage plan as submitted shows oh -site catch basins to be provided with drainage directed to llth Avenue South and 5th Street South. All utilities to the site are to be provided from 5th Street South. The City Engineer has re- viewed both of these plans and finds them acceptable. l 8. The easterly portion of subject site is located within the Nine Mile Creek Flood Plain. The applicant has appeared before the Managers of the Watershed District and received concept approval providing they meet certain requirements (see attached). Any approval by the City would be contingent upon final approval of the plan by this body. 9. The building as proposed would meet all setback requirements. A 0' yard setback is proposed at the rear of the structure. 427.38 requires a 20' rear yard setback. However, where a lot has railroad trackage abutting the side or rear of a site, the side or rear yard may be adjusted to railroad loading facilities. The appli- cant is presently requesting permission from the railroad to provide a spur line to the proposed structure. 10. The parking plan as proposed calls for 105 parking spaces for parking. 427.45 of the ordinance would require the applicant to provide 87 off- street parking spaces and thus the plan is in conformance with the ordinance. 78 truck trailer parking spaces will also be provided on the site. A portion of these spaces will be used for truck trailer storage to be moved from the Washington Avenue facility. All parking spaces will be required to comply with 427.44 of the ordinance, Design and Maintenance of Off Street Parking Areas. 11. Access to the site will be provided at three different points. The main entrance would be a new curb cut along Fifth Street South approximately in the middle of the parcel. A secondary access point would be located at the present curb cut .used by Country Club Warehouse in the southeast corner of the subject parcel. The third access point would be located at the northeast corner of the parcel_ This access point would be used for truck traffic between the subject parcel and the Washington Avenue facility. The applicant has stated that the private road to this access point would be paved. 12. If approved, the applicant should be required to enclose the outside transformer at the southwest corner of the building with an acceptable material and to provide suitable protection 'from internal traffic. 13. The applicant has stated that trash storage would be provided within the building. 14. The applicants plans show a sign located within the front yard setback. The applicant has stated they would relocate the sign out of this setback in accordance with 427.42(3) which states signs shall conform to building yard regulations for the district they are located.