Loading...
Application by SuperValu for Variance at 11th Ave. SO. & 5th St.July 21, 1981 Case No: 81 -28 Applicant: Super Valu Location: llth Avenue South Fifth Street Request: Variance from height requirements STAFF FINDINGS AND COMMENTS: Kerrigan Rafferty 1. The proposed site is zoned I -1. The applicant-is requesting a 5' variance from the maximum 35° height requirement of this district. 2. The building as proposed would be 35.5' from the first floor elevation and 40' from ground level. 3. The zoning ordinance states that a variance shall apply to a specific parcel of property because of undue hardship due to circumstances peculiar and unique upon such parcel. The applicant has stated that the reason for the variance request is because of certain design constraints required and because of the floor ele- vation required to facilitate the proposed rail spur. Aka la.,..u I t.ita CF7K4MEC tUF .G acticUII Y ECTU`' 11640 VALLEY VIEW ROAD. EDEN PRAIRIE. MN 45344 MAIL. ADDRESS' BOX 1243, MINNEAPOLIS. MN 55440 TELEPHONE: 612/828.4500 July 13, 1981 Managers of the Nine Mile Creek Watershed District c/o Barr Engineering, 6800 France Avenue South Edina, Minnesota 55435 RE: Super Valu Stores, Inc. MINNEAPOLIS DIVISION 715 5th St. So., Hopkins, MN 55343 Project 04081.4 TO the Managers: i Super Valu Stores, Inc. whose offices are located at 11840 Valley View Road, Eden Prairie, Minnesota 55344 are requesting approval from the Managers for the following: 1. An encroachment of the flood plain of up to 20% as indicated on the existing topographical survey to the proposed topographical site plan along with storm sewer and sedimentation control. 2) To permit the construction of structures for storage of equipment wholly in the flood plain meeting the following requirements: a) the structures shall be designed for the storage of tractor trucks and will not be used for human habitation; b) the structures shall be constructed of reinforced concrete perimeter walls to above the flood plain to eliminate flood damage potential. c) The structures shall be constructed and placed on the building site to be near the end of the reach of the water flow to offer minimal obstruction to the flow of water. 1. The structures shall be constructed with the longitudinal axis parallel to the railroad tracks which is also parallel to the cd i rection of the flood flow. 2. The structures shall be placed, if practical, in approximately the same flood flaw lines as those of adjoining structures. d) The structures shall be firmly anchored by grade beam footings, piles or caissons to prevent flotation. e) Service facilities to the structures,'such as electrical and heating equipment, shall be installed above the regulatory flood protection elevation. f) The finished fill elevation shall be no more than one (1) foot below the regulatory flood protection elevation for the particular area. 4 July 13, 1981 MINNEAPOLIS DIVISION Project #4081.4 Pagetwo.... g) The structures will be constructed with a reinforced concrete slab on grade without a lower level. h) The storage will be for tractor trucks only. Sincerely, PLANIARC Engineering /Architecture A Division of Super Valu Stores, Inc. Lidberg, P.E. Senior Project Manag cc: Bob Obermeier Barr Engineering TEL/pas We thank the managers for their consideration with regard to the above request. a w ,,x