Loading...
Cond. Use Permit-Stiele• • Supporting Documents. o Location Map Design Plan November 17, 1988 Planning Report: CUP88 -17 Proposed Action Staff recommends approval of a Conditional Use Permit for the renovation of 918 -924 Mainstreet and 3,5,7 10th Avenue South. This action will allow the applicant to renovate these buildings for retail and residential uses. Overview. 918 -924 Mainstreet and 3,5,7 10th Avenue South is currently owned by the HRA. Most of this block was purchased by the HRA in 1984 for redevelopment. Since the purchase of these buildings, the City has been attempting to redevelop the entire block. However, attempts to redevelop the whole block as one project have been unsuccessful so the City now is in the process of redeveloping each building individually. 918 -924 is the second building on the block to be rehabilitated. Last month Marcus Corporation was approved to redevelop 906 -908 Mainstreet. The HRA is selling the property under a redevelopment agreement. The building is being renovated under the Downtown Hopkins Design Guidelines which are enclosed. Issues to be Considered. Is this renovation consistent with the City's redevelopment plans? qlonlio4 � NancycS Anderson Community Development Analyst CONDITIONAL USE PERMIT - STIELE 918 -924 Mainstreet Downtown Design Guidelines Resolution No. 88 • Detailed Background. CUP88 -17 Page 2 Exterior Improvements: The existing exterior will be renovated. The renovation will consist of cleaning the outside brick, new windows and doors, new awnings and new brick to match on the south end of building. Interior Improvements: Much of the work will be interior renovation. The following is the work to be done: - new plumbing - new wiring - new lighting - walls and ceilings redone - stairways repaired and remodeled - new air conditioning systems - new heating - complete sprinkling of entire building The building will essentially remain the same. There will be two entrances on 10th Avenue and two on Mainstreet. The applicant will not be changing the footprint of the building. The buildings are to be used for retail on the first floor and residential on the second. The existing buildings do have residential on the second floor. As of this time the applicant does not have any committed tenants. Is this renovation consistent with the City's redevelopment plans? Since the acquisition of the property on this block, the City has been trying to redevelop the block into retail /office. The applicant is proposing to have retail on the first floor and residential on the second. The applicants proposal is consistent with the City's redevelopment plans for the City. The renovated retail space and apartments will provide new opportunities for both retailers and renters. Alternatives. 1. Approve the Conditional Use Permit for the renovation of 918 -92 Mainstreet and 3,5,7 10th Avenue South. This would allow Mr. Stiele to renovate the above buildings into retail /residential. CUP88 -17 Page 3 2. Deny the Conditional Use Permit to renovate 918 -924 Mainstreet and 3,5,7 10th Avenue South. If the Commission chooses this option they will have to state findings of fact that support this alternative. 3. Continue for further information. If the Commission feels more information is needed, the item should be continued. 0 EXCELSIOR r DOWNTOWN HOPKINS DESIGN GUIDELINES FACADE STANDARDS: The recommended general- design standards for structures and sites in downtown Hopkins are as follows: 1. Facade standards apply to building fronts and exposed sides and rear walls. 2. The distinguishing original qualities or character of a building and its site, where still in existence, should not be destroyed, removed or altered. 3. All building structures and sites should be recognized as products of their own time and it is the intent of these standards to pre- serve, as nearly as possible, the architectural features of such time. However, changes which are evidence of the history and develop- ment of a building, structure or site and its environment, shall be preserved, when possible, if those changes have acquired a recognized and respected significance of their own. 4. It is not the intent of these standards to exclude modern design or to inhibit creative initiative. In instances where faithful restora- tion or replication is not practical, historically or economically justified, remodeling may be done in a contemporary manner, sym- pathetic with and complimentary to the general character of the Mall. Such renovations or alterations should not destroy significant historical, architectural, or cultural material. Buildings should be considered as total units from grade to cornice line and should be designed in a way that the total facade is a harmonious unit. Distinctive stylistic features of a building should be preserved When- ever possible in a condition or appearance as near as possible to their original appearance. Deteriorated architectural features should be repaired and restored rather than replace, whenever possible. In the event replacement is necessary, the new material should match the material being replaced in composition, design, color, texture and other visual qualities. Repair or replacement of missing architectural features should be based on accurate-duplications of such features where possible and appropriate. However, new show windows, lighting, hardware; details, ornament, doors, and other elements may be designed in a way sympathetic and complementary with the spirit and character of the building. 6. Solid, permanently enclosed or covered facades will not be approved. All upper level windows should be fully exposed. Windows should be replaced or repaired as necessary and maintained in a condition to give an "occupied" look. A minimum of 40Z of the area of the Ground Floor- shall be comprised as doors and /or transparent material. Doors may be solid or opaque, or a combination of both. Opaque or translucent windows or material shall not be considered transparent. FUNCTIONAL STANDARDS: The general sunctional standards for structures and sites should be as follows: I. All structural and decorative elements of building fronts and sides'exposed to view should be made structurally sound. Deteriorated or missing portions should be repaired or replaced in a workmanlike manner. All facade elements and elements exposed to view should be well maintained, cleaned and painted, as required. DESIGN GUIDELINES PAGE TWO 2. All lighting and electrical elements including wiring, conduits, junction boxes and all elements of mechanical equipment including pipes, ducts, air conditioning units, should where possible, be concealed from view. All non - functioning elements should be removed. 3. The surface cleaning of structures must be undertaken with the least damaging method possible. Sandblasting and other cleaning methods should not be used as these methods can unalterably damage historic building materials such as brick. 4. Roofs: Roofs and chimneys or other auxiliary structures on the roof should be repaired and cleaned as required. Any construction visible from the street should be finished so as to harmonize with other visible building walls. Television and radio antennae should be located in an incon- spicuous manner. SIGNS: The general design standards for signs shall be as follows: 1. Definitions a. Sign: The word "sign" means any letters, pictorial representation, symbol, flag, emblem or illuminated device displayed in any manner whatsoever, which directs attention of persons off the premises on which the sign is displayed to any object, subject, place, .persons, activity, service, institution, organization, or. business. b. Dimension of a sign: The words "dimension of a sign" means total dimensions enclosing the extreme limits of letters or perimeters of backgrounds, borders, emblems, color or frame or any device used to distinguish the sign from the building surface on which it is placed. Except as stated, structural supports shall be considered part of the sign. 2. General: a. It is not the intent of these standards to create uniformity of signage or to inhibit creative initiative. b. Signs should be designed and placed so as to appear an integral part of the building design, to be consistent with the period of the building, to respect neighboring properties and the district in general. Signs shall be designed with appropriateness relative to the services of the establishment served. 3. Recommended Signage: a. Signs that are determined to be an original part of the existing building facade should be retained and maintained. A sign will be considered to be an "original part ", if it was included as a component of the existing facade design and.construction. b. Primary Signs: Each Ground Floor occupant in a building should have more than one sign oriented to each public right -of -way on which the premises have frontage. This (these) sign(s) should identify the predominant use of the occupant or identify the building as a whole. 1) Primary signs may extend the entire length of the facade but should have a total vertical dimension of no more than two feet six inches (2'6 "). Primary signs should not overlap horizontally. Primary signs should be mounted no lower than eight feet (8') above the elevation of the Ground Floor and no higher than the elevation of the Second Floor. 3) Primary signs may be painted directly on glass show windows or entry doors, in which case they may be located at any point below the eleva- tion of. the Second Floor but must be painted directly on the glass. Such signs should have a vertical dimension no greater than one foot (1'). • DESIGN GUIDELINES PACE THREE c. Secondary Signs: Each building may have one or more secondary signs. These signs should identify occupants on upper floors or occupants not considered the primary building user. 1) Each occupant may have not more than one sign painted directly on glass of upper windows. Upper window signs should consist of individual letters not over six inches (6 ") in height painted vertically on glass. Total sign dimension should be not greater than fourteen inches (14 ") in height. 2) In addition to upper window signs, each occupant may have one ground floor entry sign located at entryway with individual letters painted or located directly on glass, door, plaque or directory. Total dimensions of entry signs, regardless of number of occupants identified, should not exceed two feet six inches wide and one foot six inches high (2'6" X 1' 6 "). d. Overhanging signs: Overhanging signs are permitted at horizontal intervals. along the front property lines of not less than twenty -five feet (25' 0 "). Overhanging signs should be no greater dimension than eighteen inches wide by sixteen inches high (18" X16 "), shall extend no more than twenty -four inches (24 ") from property line and shall be mounted no lower than eight feet (8'0 ") from elevation of Ground Floor. 4. Signage Not Recommended: a. No signs should be used other than those identifying a property where they are installed or identifying the use conducted therein: Advertising by material or product manufacturers is not recommended. b. No sign or light should move, flash, or make noise. (With the exception of signs displaying time, temperature, public information and barber totems.) c. Plastic or transparent "panel" signs will be reviewed for appropriateness for the particular building on an individual basis. They will be dis- couraged on buildings with historic character. 5. Illumination: Any sign lighting shall be properly shielded or diffused so as to eliminate glare. 6. Exceptions to the sign recommendations: The following are appropriate in addi for to those signs listed above: a. Names of buildings, dates of erection, monumental citations, and commemorative tablets which do not exceed 20 square feet in area when made a permanent in tegral part of a building. b. Educational signs not exceeding 10 square feet • g q providing bulletin or poster display space, identifying or explaining local history or. processes going on out of sight within the building. PROJECTIONS BEYOND PROPERTY LINE: There should be no projections beyond the propertY line other than as described below: 1. Sun protection /weather protection devices may be permitted only in the form of awnings on existing buildings. Awnings shall be operable or retractable, and they shall be of convas on metal frame. Awnings should have a minimum slope of twenty degrees (20°) to the horizontal. Awnings should be located no higher than sixteen feet (16') and should extend no lower than eight feet (8'). Awnings.should be designed in a way to appear an integral part or the building facade design. 2/84 DESIGN GUIDELINES PACE FOUR 2. Fixed canopies or marquees are not recommended. but will be considered on an individual basis. 3. Overhanging signs as described above may be used. 4. Individual wall lighting fixtures projecting beyond property lines may be used providing that fixtures are consistent with the period of the design of the building facade; that the total wattage per fixture does not emit glare or harsh bright spots; that the fixture is mounted no lower than six feet six inches (6' 6 ") nor higher than nine feet (9' 0 ") above the elevation of the Ground Floor; and provided that the fixture extends from the property line not more than sixteen inches (16 ") nor have any dimension greater than sixteen inches (16 "). GENERAL: 1. Uses: Nothing contained in this article shall effect the present use of any property therein. Use classifications for all property included within the district are governed by the Zoning Ordinance of the City of Hopkins and the procedures therein established. 2. Other Standards: These guidelines are recommended for use a a supplement and complement to the Building and Housing Codes of the Ctiy. Nothing contained herein shall be construed as repealing the applicability of any provision of the Building Codes. Instead, the design guidelines are in addition to such standards as are set forth in the Building Codes of the City of Hopkins. IoF2 N a F I T " � W E EJAT IOh1 - VISUAL h4-1L P PRELIMINARY DEhicvN dF ED STIFLE UILCA.16v 1�4 I 1 -3-88 5509 EDEN PRAIRIE ROAD MINNfTOHKA. MINNESOTA VW-MG) (,.�Q (� 55345 `ga °V (6171933:3011 NoIn gIIIIIYIIIRII111&IINI M Illlglll�llll■t ._... 4' e' De Iv.. - ad VISUAL a<Alf. PIPM°111 gpi �e11 pREL-iMf ARY of Eb - 1 - 1 E fit„ 1 I LDI IJ& �IIIINIIIIRI Ho (e � 5S09 EDEN PRAIRIE ROAD. ci(_lro MINNETONKA, MINNESOTA t1 ® @OCJ (6121931.3011 CITY OF HOPKINS Hennepin County, Minnesota RESOLUTION MAKING FINDINGS OF FACT AND APPROVING APPLICATION FOR CONDITIONAL USE PERMIT CUP88 -17 WHEREAS, an application for a Conditional Use Permit entitled CUP88 -17, made by Harold Stiele, for renovation of the building at 918 -924 Mainstreet is approved. WHEREAS, the procedural history of the application is as follows: 1. That an application for Conditional Use Permit CUP88 -17 was filed with the City of Hopkins on November 3, 1988. 2. That the Hopkins Planning Commission reviewed such application on November 29, 1988. 3 That the Hopkins Planning Commission, pursuant to published and mailed notices, held a public hearing on November 29, 1988; all persons present at the hearing were given an opportunity to be heard.. 4. That the written comments and analysis of the City Staff and the Planning Commission were considered. NOW THEREFORE BE IT RESOLVED, that the Hopkins City Council makes the following Findings of Fact in respect to CUP88 -17: 1. That the renovation meets the development plans for the area. 2. That the renovation will comply with the Hopkins Downtown Design Guidelines. Adopted this 13th day of December, 1988. Donald J. Milbert, Mayor