Cond. Use Permit-Rolfe Office Bldg.TO: Zoning & Planning Commission FROM: Nancy Anderson Planning Commission Report August 11, 1986 SUBJECT: Conditional Use Permit for Rolfe Office Building The applicant was approved for a Conditional Use Permit in September 1984 and received a year extension in September 1985. 427.26(5) states a Conditional Use Permit shall expire one year after it has been issued unless the use for which the permit has been granted is in effect, except that upon written application of the owner of the effected land for which the permit was granted prior to the end of said year may request and the Council may grant an extension not to exceed one year. in 1984. The proposed building remains the same as the building proposed The applicant has not constructed the building because he has had a problem securing tenants. 11111 V4 1.11.O! AI I01 Nancy ' Commu . Anderson, Analyst ty Development 4- • • • August 23, 1984 Case No: 84 -27 Applicant: W. Pitt Rolfe Location: Second Avenue South & 7th Street South Request: Conditional Use Permit for Construction of an Office Building STAFF FINDINGS & COMMENTS: 1. Applicant is requesting a Conditional Use Permit to construct an office building. 427.26(c) requires a Conditional Use Permit for new construction over $75,000. 2. The subject site is located North of 7th Street South and between Second Avenue South and County Road 18. The site is zoned B -1, Limited Business. 3. The proposed office building is to be 14,268 square feet. The building is three stories high with a mean building height of 25 feet. The first floor of the building will be below street level with an elevation of 893.0 feet, the average street elevation is 900 feet. The exterior of the building is to be constructed of brick, with the windows being constructed of bronze insulated glass. 4. The proposed use for the office building is a dentist office occupying the first floor, an accounting firm on the second and the occupancy for the third floor is unknown at this time. 5. The structure as presented would have a 38 foot front yard setback along Second Avenue South, a 68 foot rear yard setback along County Road 18, a 80 foot sideyard setback to the North and a Southerly side yard setback of 20 feet along 7th Street South. Ordinance 427.35 requires setbacks of 20 feet for the front yard, 10 feet for the rear and 10 feet for the side yards. 6. An office building is located to the North of the subject site, single family homes to the West, buffered by trees, construction of a medical clinic to the South and Highway 18 to the east. 7. 58 parking stalls are to be provided with an entrance /exit from the Northwest. 14 compact stalls are provided along with two handicap stalls. The number of parking stalls are in compliance with ordinance 427.45(20) which requires at least one parking space for each two hundred and fifty square feet of gross floor area for office. The ordinance requires 57 parking stalls based on these requirements. 8. The perimeter of the parking lot is to be landscaped with sod and a variety of over and understory trees. The landscaping would conform to the requirements of the proposed landscaping ordinance. 9. The drainage plan has been reviewed by the City Engineer and has been found acceptable. Drainage will flow in a Northwesterly direction on the site. 4- • Case No: 84 -27 Page 2 10. Ordinance 427.35 requires a maximum Floor Area Ratio of 1.0. The proposed building has a F.A.R. of .39 which meets the requirements of the ordinance. 11. Trash storage is to be located at the Northeast corner of the site and en- closed with a 5 foot high redwood fence. 12. Access to the proposed site will be from the Northwest corner from Second Avenue South. 13. The Fire Marshal has reviewed the plans and noted that the building must be sprinkled, any other Fire Code requirements will have to be complied with at the building permit stage. • ROLFE OFFICE BUILDING .HOPKINS, MINNESOTA OFFICE AREA • 4 -4 ■ FLOOR PLAN ( 6ECONO FLOON SHOWN) SITE PLAN SITE DATA wwwwwwwwwwwwwwww ZONING SITE AREA BUILDING COVERAGE GREEN AREA ...ter REQUIRED PARKING — PARKING PROVIDED — MEAN BUILDING HEIGHT ALONG SECONO AVE., SEVENTH STR.& C.R.16 • TH STREET. *WWII BI 36,340 S.F. .53 AC. 4756 S.F. 13% OF SITE 10,000 B.F. 30% OF SITE 6/250 SF. X .14,266 S.F. . 57 55 24.3' .•.. t.#__ n$ .09 w wr +.t +)1 1111 1 1,,1( Car CI eS' • M. RPM 1R ■ 1..611 6w• • �Y 1 . W ,.1.) 11 r 1 1. 41./e INS • 1.1.1 I* MI41• rwar X11. F1R ' r 1 1.q •.1• . • 11../1. 1.r uava noaa •rwoa as • m 11. I ■l1.mlre ■JT r •wrlr. ■1.1.1..1 Fur • r 1 n.1. wlw 1..1. Ileo r_1.■ r I 'Oar raw11 . s1••t11w .a.1.11 r wry • Jr... V ravel 6arw w•1..11 �1•. r w.0 J Y_ il.r LANDSCAPE PLAN wllslr. =noir* ws r Ir101 rl._.a ....1..,w 61.. r w..1. a Jr w1.t114 IM.IIIL wrli l.1.. r wrr 7 TH STREET SOUTH GRADING PLAN 7 TH STREET 5017711 O 2 9 m w U E. O c sti 12 NORTH Fl FVAT1ON soun-LELEVATION 11 I 1 :11_1; - 7 - T. ry ' • • 1 1 1.f I 1 1 1 1 1 1 1 T. _WEST_ELEVATION 4ASI_ELEVATION • _.• z • a 1 11111 ,1•■•••■■■•■• co w 0 E. 0 w u. 1 0 CC