Loading...
Cond. Use Permit-Warrington Associates Inc.CONDITIONAL USE PERMIT- WARRINGTON ASSOCIATES, INC. PURPOSE: The purpose of this report is to review and recommend action on a Conditional Use Permit to construct an office building. BACKGROUND: Planning Commission Report Name of Applicant : Warrington Associates, Inc. Address of Property: Vacant lot north of 601 2nd Avenue South. Present Zoning: B -1 Reason for Request: To construct a 14,500 square foot office building. Nature of Request: Ordinance requires a Conditional Use Permit for construction over *75,000. The applicant is proposing to construct a 14,500 square foot building on the empty lot just north of the present site of the Warrington building at 601 2nd Avenue South. 427.26 (c) requires a Conditonal Use Permit for construction valued over *75,000. The proposed building will also be connected to the present Warrington building by a link. The applicant has applied for a side yard variance. B -1 REQUIREMENTS Lot Area 5000 sq ft Lot Width 50 sq ft F.A.R. 1.0 Front Yard 20 feet Side Yard 10 feet Height 25 feet The proposed building has no through lot. rear yard since it is a The proposed building will be 12 feet in height however due to the elevation the proposed building will be lower than the existing Warrington building. The abutting residential district is buffered by a berm and trees. N o. CUP86 -10 September 18, 1986 PROPOSED BUILDING 97,807 sq ft 312.35 sq ft .15 East 22 feet West 22 feet North 241 feet South 0 12 feet CUP86 -10 Page 2 The applicant is required to have 25 trees. The applicant is proposing to have 31 trees of various types. The applicant will also be retaining many of the existing trees on the site. Access to the site will be from 2nd Avenue at the north end of the site. The parking area will be connected to the building by a 5 foot concrete walk. The applicant will contact the Watershed District and obtain approval if necessary. The exterior of the building will be brick. The applicant has contacted the neighborhood organization. The Director of Engineering has reviewed the drainage, as of the date of this report and saw no problems with the plan. The Fire Marshal has reviewed the plans and noted that a fire door will have to be constructed in the link, however, the final placement will be done at the building permit stage. The applicant may in the future construct another building to the north of this building, however, at that time the applicant will have to apply for another Conditional Use Permit and have the development reviewed at that time. The applicant has not detailed the lighting for the parking area, however the lighting will have to conform to 427.44 which requires the lighting to be shaded or diffused from the adjoining property and away from abutting traffic. ANALYSIS: The proposed building meets the requirements for the B -1 District with the exception of the link to the existing building. However, if this link is removed the proposed building could exist independently and conform to the ordinance. The heights of the buildings along Second Avenue has been a concern of the abutting neighborhood, however, with the proposed elevations this building will be lower than the present Warrington Building. The applicant is proposing to leave many of CUP86 -10 Page 3 the existing trees which will also minimize the impact to the surrounding area. RECOMMENDATION: I recommend approval of the Conditional Use Permit. The following are suggested Findings of Fact should the Commission recommend approval: 1. The proposed building meets the requirements for the B -1 District. 2. That the proposed building meets the requirements for a Conditional Use Permit. Ackcipkym Nancy . Anderson, Commu ity Development Analyst